6.2        Fire trails and FRZ Standards
The nature of a fire trail and fuel reduction zone depends on two main factors:

        Neighbouring assets: The nature of the neighbouring assets within 100m will determine the
         width of a fire trail and/or FRZ. The higher the risk, the greater the width of the fire trail to allow
         large fire appliances
        Slope: The primary purpose of a fire trail is to allow access for fire appliance vehicles. If the
         slope of the land is greater than 20 degrees or there is highly unstable soil, then this will restrict
         access for vehicles.

A single reserve can have multiple types of fire trails and FRZ’s depending on changes in slope and
the types of neighbouring buildings. Table 7 provides a general guideline for fire trails/FRZ for
reserves with High to Very High bushfire risk.

    Bushfire         FMU           Asset Protection Zone            Fire unit      Maintenance
    Interface        Assessment    (APZ)                            access         requirements
    Zone risk                      Fire access   Fuel
    assessment                     trail width   Reduction
                                                 Zone (FRZ)
                                                 width
    Category A Vulnerable persons and buildings
    (e.g. nursing homes)
    1                <20 degrees   15m           5m                 Large fire     Fire trails every 3
                                                                    appliance      months
                                                                    can access     FRZ every 3 years
                                                                    and turn
                                                                    around on
                                                                    trail.         Slashing/mowing
                         Narrow          3m           N/A           N/A control    every 3 months
                         vegetation                                 line only
                         corridor
    2                    >20 degree      N/A          20m           N/A            FRZ every 3 years
                         slope and/or
                         highly erodible
                         soil.
    Category B Essential service and hazardous
    facilities (e.g. utilities)
    3                    <20 degrees     10m          5m            Large fire     Fire trails every 3
                                                                    appliance      months
                                                                    can access     FRZ every 3 years
                                                                    and
                                                                    undertake 3
                                                                    point turn     Slashing/mowing
                                                                    on trail.      every 3 months
                     Narrow            3m             N/A           N/A control
                     vegetation                                     line only
                     corridor
    4                >20 degree        N/A            15m           N/A            FRZ every 3 years
                     slope and/or
                     highly erodible
                     soil.


    Category C Residential buildings and facilities
    5              <20 degrees       4m               N/A           Medium and     Fire trails every 4
                                                                    small fire     months
                                                                    appliances
                                                                    can have



DRAFT Noosa Bushland Reserve Strategic Fire Management Plan                                              Page 20
Log in to download the original file

2021-06-08 P&E Agenda - Item 7 - Attachment 1 - Noosa Bushland Reserve Strategic Fire Management Plan 2021(PDF, 3MB).pdf · 3.3 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.