Council archive · source document
06/0823 - Applicant's Response to Information Request including Attachments [As Published] · 132006.823
Very large file (42.4 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
24. Each driveway has a minimum width of 5.5 metres. Long-sections for each basement carpark entrance are included in Attachment 12. It is noted that all basement entry ways have been checked in detail and it can be confirmed that all accesses comply with normal grading and clearance requirements. 25. 25. it is noted there are some garages/carpark spaces that do not appear to comply with the manoeuvring requirements of AS.NZS2890.1-2004. The following examples were noted for non-compliance:- 25.1 The last garage in B Block for unit B-1d; 25.2 The access for D-15a; 25.3 Space 17 under E Block; 25.4 The entry to both E Block and the Health Spa parking; 25.5 Garages for G Block are difficult to reverse out of: 25.6 The dimensions of the “small car’ spaces under K Block are incorrect: 25.7 Entry to carpark spaces 1 and 2 under N Block will require reversing in and 25.8 The access for Q-168a. The garages and carpark spaces identified in parts 1 to 8 of Item 25 have been reviewed and the following amendments have been made. It is noted that turning circles for sections 1, 2, 4, 5 and 8 are provided in Attachment 13. 25.1 25.2 25.3 25.4 25.5 25.6 25.7 25.8 A 2 metre reversing bay has been provided and the bins have been shifted north. Access to C15a (D15a) has been revised to include a reversing bay. The width of carpark bay 17 under Building D (E) has been widened to increase manoeuvrability. A turning circle of 7.5 metres radius has been used to provide access to the parking area of Building D (E). The garages associated with Building E (G) have been reduced to a single car garage. The width of the ‘small car' spaces under Building G (K) have been revised and are now compliant. It is not considered a reasonable request to require all 220 internal spaces provided on the site to be able to be entered via a forward motion. A 6.8 metre aisle width has been provided to assist with manoeuvrability (1 metre in excess of minimum). It is considered that Council's request refers to the access for Q-186a, rather than the stated Q-768a. Turning circles included in Attachment 13 demonstrate the compliance of this space. Page 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/0823 - Applicant's Response to Information Request including Attachments [As Published]Related documentApplication case desk ↗
About this file
- File size
- 42.4 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.