Council archive · source document
2023-03-16 - 2-30 Hastings Street, Noosa Heads - DEVELOPMENT APPROVAL ISSUE (PRELIMINARY) · 51983.3225.17
ADJOINING VILLA . 4 o— —- —— a BOUNDARY 3 ADJOINING - pT ~ 2A 3] VILLA ry ex) 3] ee) 4 | of BI \. 58 i | ~ & 3 4 | 2290 Exe. ~ 13 3 = | [a SETBACK a 33 ADJOINING 3 3 VILLA ROADWAY EXISTING esac | BUILDING 2 | OUTLINE 3 - I \ K\ oA “ ADJOINING ls SHARED ADJOINING ~~ “BOUNDARY an ROADWAY SHARED ° BOUNDARY o ie ROADWAY (DEDICATED LOT Bw EXCLUSIVE USE AREA) (01 \ EXISTING SETBACKS - LEVEL 2 Yo) SCALE 1:100 NOTE UNLESS NOTED OTHERWISE, ALL EXISTING BUILT WORKS ARE TO REMAIN. FOR FURTHER CLARIFICATION ON EXTENT OF DEMOLITION WORKS, REFER TO PROPOSED FLOOR PLAN FOR PROPOSED RECONFIGURATION LAYOUT, WALL SETOUT DIMENSIONS AND OPENING LOCATIONS. NOTES 1. ALL CONSTRUCTION WORK UNDERTAKEN |S TO COMPLY WITH THE NATIONAL CONSTRUCTION CODE (BCA), RELEVANT AUSTRALIAN STANDARDS AND APPLICABLE LOCAL AUTHORITY REQUIREMENTS. 2, ALL SETBACK/SETOUT DIMENSIONS ARE TO BE CHECKED AND VERIFIED ON SITE NOTE: THESE DRAWINGS ARE DESIGN CONCEPTS ONLY AND SHALL NOT BE USED IN ANY WAY FOR STRUCTURAL PURPOSES. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL MEMBER SIZES, SPECIFICATIONS AND SITE SPECIFIC STRUCTURAL REQUIREMENTS. PRIOR TO CONSTRUCTION. ADJOINING s VILLA = t+-— o— —- —_— _ _ m __ BOUNDARY _ g| 5 ADJOINING T 3 3 = VILLA | en g 875 \, +) z S = | SETBACK 228 \ | 352 | z aN Bo ADJOINING 3 ZZ a VILLA PROPOSED - | ROADWAY BUILDING A SETBACK 1305 OUTLINE & | SETBACK |/ 5 ++ ——o ADJOINING fs BOUNDARY -- DECK OUTLINE TO MATCH EXISTING SHARED ° BOUNDARY Ci ROADWAY EXCLUSIVE USE AREA) (2 YT) SCALE 1:100 NOTES: 4, THIS IS A COMPUTER GENERATED DRAWING, DO NOT AMEND BY HAND. 2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. 3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. 4. DO NOT SCALE THIS DRAWING. COPYRIGHT: © GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN. AMENDMENTS REV___DATE _DESCRIPTION ‘A. |xx.03.2023 ] ISSUE FOR DEVELOPMENT API PROVAL, [Auton Ge | ORIGINAL SHEET SIZE: A3 [420x297mm] ee DA ISSUE PROJECT ADDRESS PROPOSED RESIDENTIAL ALTERATIONS 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 DRAWING SETBACK DIAGRAMS - LEVEL 2 DRAWING CREATED SCALE @A3 AUG 2022 1:100 PROJECT NO, REVISION 22048 A DWG. NO. DA005 GT GROUP www.gtgroup.net.qau [email protected] ere RPP (07) 3298 6938
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2023-03-16 - 2-30 Hastings Street, Noosa Heads - DEVELOPMENT APPROVAL ISSUE (PRELIMINARY).pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.