3 Vehicular Site Access Arrangements
Two separate vehicular accesses are proposed to Gateway Drive including an entry-only crossover located
adjacent the southern site boundary and an exit-only crossover located adjacent the northern site boundary.
The provision of two accesses is necessary for the development due to the need to establish 1-way internal
circulation for the design vehicle (19m articulated vehicle).
3.1 Design & Location
Acceptable Outcome AO1.1 of Council’s Driveways and Parking Code requires vehicular access to be designed
and located in accordance with the Australian Standards for Parking Facilities (AS/NZS 2890.1:2004 and AS
2890.2:2018). Tables 3.1 and 3.2 summarise the design and location compliance of the proposed accesses.
As indicated, the design and location of both accesses complies with the standards. As demonstrated in TTM
drawing 21BRT0226-03B (Appendix B) the access layouts and widths accommodate the swept path of the
adopted design vehicle (19m articulated vehicle).
Table 3.1: Design Compliance Summary – Southern Entry-only Access
Design Aspect Council Requirement Proposed Provision Compliance
Distance from an 6m 130m Compliant
intersection
Type Heavy duty in accordance with IPWEA Heavy duty in accordance with Compliant
standard dwg. RD-S-051 IPWEA standard dwg. RD-S-051
Width Adequate for design vehicle swept path 9.5m Compliant
Gradient 1:20 (5%) first 6.85m 1:20 (maximum) Compliant
Minimum Queuing 2 car lengths (12m) 18m (minimum) Compliant
Provisions
Table 3.2: Design Compliance Summary – Northern Exit-only Access
Design Aspect Council Requirement Proposed Provision Compliance
Distance from an 6m 165m Compliant
intersection
Sight Distance - 69m >120m (minimum) Compliant
50kph
Type Heavy duty in accordance with IPWEA Heavy duty in accordance with Compliant
standard dwg. RD-S-051 IPWEA standard dwg. RD-S-051
Width Adequate for design vehicle swept path 7.0m Compliant
Gradient 1:20 (5%) first 6.85m 1:20 (maximum) Compliant
Site: Hardware & Trade Supplies Development – 178 Eumundi Noosa Rd, Noosaville QLD
Reference: 21BRT0226
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment D - Traffic Response.pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.