 Performance Outcomes                         Acceptable Outcomes                     Response

                                              Canopy trees are protected from
                                              vehicle damage by providing
                                              adequate sized garden beds.

                                              AO11.5                                  AO11.5 Complies

                                              Plants with thorns, fruit or berries    Plant species have been
                                              are avoided in car parks.               selected to avoid these aspects.
                                                                                      Refer to Appendix D for further
                                              Editor's note— Refer to Figure AP3-5B
                                                                                      detail.

 Services, utilities and                      AO12.1                                  Not Applicable
 infrastructure
                                              Vegetation planted within the           Not easements are located within
 PO12                                         easement of an overhead                 the site.
                                              powerline or, where there is no
 Vegetation does not pose a risk
                                              easement, the area of influence
 to the safety or reliability of
                                              of a powerline, has a mature
 services, utilities or infrastructure
                                              height of no more than 3.5
 including substations, overhead
                                              metres.
 powerlines, power poles and
 transformers, street lamps,                  AO12.2                                  Not Applicable
 stormwater catchment pits, and
 underground services and                     Vegetation planted within an            Not easements are located within
 utilities.                                   underground powerline                   the site.
                                              easement does not have a
                                              mature root system in excess of
                                              150 millimetres in depth and is
                                              not located directly over the
                                              powerline.

                                              AO12.3                                  Not Applicable

                                              Regardless of the width of the          Not easements are located within
                                              easement, vegetation adjoining          the site.
                                              easements must be separated
                                              from the power pole or other
                                              infrastructure by a distance at
                                              least equal to the maximum
                                              mature height of the vegetation.

                                              AO12.4                                  Not Applicable

                                              For power lines that connect to a       Development is supported by a
                                              premises, the height of plant           dedicated substation.
                                              species at maturity provides for a
                                              2 metre clearance below the
                                              power line

                                              AO12.5                                  AO12.5 Complies

                                              With the exception of electricity
                                              infrastructure, trees and large


URBIS
FINAL TOWN PLANNING REPORT - 47 GOODCHAP STREET                                         PLANNING SCHEME CODE ASSESSMENT   91

Log in to download the original (Appendix L - Code Assessment.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.