 Performance Outcomes                     Acceptable Outcomes                       Response

                                              (b) has a bund wall with a
                                                  maximum height of 100
                                                  millimetres;

                                              (c) is serviced by a
                                                  conveniently located
                                                  hosecock and backflow
                                                  prevention device, and
                                                  connected to a water
                                                  supply; and

                                              (d) is roofed or otherwise
                                                  covered if the storage area
                                                  is—

                                                  i.   more than 1m²; or

                                                ii.    storing wet waste; or

                                                iii.   storing other waste
                                                       with a high potential to
                                                       cause pollution if
                                                       washed or leaked from
                                                       the bins, including
                                                       waste oil or
                                                       putrescibles.

 Safety and protection of infrastructure when demolishing or removing buildings

 PO7                                      AO7.1                                     AO7.1 Can Comply

 Demolition, removal, relocation          Infrastructure including reticulated      Council may wish to condition
 or associated works do not               water, sewerage, stormwater, and          the necessary plans for
 result in:                               electricity are protected from            demolition/removal of the
                                          damage and made safe to the               existing buildings on site.
 'live' or 'active' infrastructure that
                                          standard required by the regulatory
 may present risk to people using
                                          authority.
 the site or surrounding areas; or
                                          AO7.2                                     AO7.2 Complies
 damage to infrastructure or
 other works.                             Infrastructure is disconnected,           Infrastructure will be
                                          capped or sealed including:               disconnected, capped or sealed
 Editor's note— An approval will
                                                                                    accordingly as part of the
 be required from Council's                   (a) electricity meters are
                                                                                    proposal.
 Building and Plumbing Services                   removed and electrical
 for decommissioning plumbing                     wires disconnected;
 apparatus including:
                                              (b) telephone lines are
 sanitary drains or reticulated                   disconnected; and
 water supply; and
                                              (c) data cables are
 septic tanks, holding tanks or                   disconnected and
 on-site treatment systems.                       removed.




                                                                                                                         URBIS
112PLANNING SCHEME CODE ASSESSMENT                                             FINAL TOWN PLANNING REPORT - 47 GOODCHAP STREET

Log in to download the original (Appendix L - Code Assessment.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.