                                                                                                                                                                              FIGURE 2:
                                                                                                                                                                               EXISTING TREES (MELALEUCA WITH FICUS SP.)
                                                                                                                                                                               TO REMAIN IN FRONT OF THE EXISTING SHOP
                                                                                                                                                                               (VIEW FROM THE NORTH, APRIL 2021).
                                                                                                                                                                               EXISTING RETAINING WALL TO BE REMOVED.
                                                                                                                                                                               REFER TO NOTES ON SHEETS 20313-L-02 and L-05
                                          FIGURE 1: LOCALITY PLAN (NTS)


                         SUBJECT SITE AND LANDSCAPE DESIGN
                         The subject site is located at 13 Noosa Drive Noosa Heads Qld 4567 on Lot 5 RP 91777.
                         A development permit for Material Change of Use of Premises (Shop & Short Term Accomodation) has been issued.
                         All landscaping works are to be undertaken in accordance with Council's Decision Notice, dated 22 February 2021.
                         Trees identified for retention, as shown on the Tree SRZ Layout Plan, Drawing No. P07, Issue A, prepared by 360 Civil
                         Consulting and dated September 2020, must be retained (refer to Page 5 of 11 of the Decision Notice).
                         An arborist report with detailed information about Tree Protection Methodology has been prepared by Kurt Brown,
                         dated 22/02/2021.
                         Refer to engineer's specifications regarding drainage, stormwater runoff, water detention and root barriers.
                         The proposed planting shall enhance the visual amenity of the new development, be hardy and suitable for the
                         coastal conditions.
                                                                                                                                                                              FIGURE 3:
                                                                                                                          COUNCIL REF. :                                      EXISTING TREES ON THE ADJOINING LOT
                         LIST OF SHEETS                                                                                   MCU20/0103                                          TO THE NORTH AND EXISTING DRIVEWAY
                                                                                                                                                                              (VIEW FROM THE STREET, DATED APRIL 2021)
                              L-01    COVER
                              L-02    LANDSCAPE PLAN & PLANT SCHEDULE A
                              L-03    'VERTIKAL GARDEN' & PLANT SCHEDULE B
                              L-04    PLANTING NOTES                                                                         -


                              L-05    LANDSCAPE SPECIFICATIONS
                                                                                                                             -
                                                                                                                     APPROVED PLANS
                                                                                                                        OPW21/0104
                                                                                                                 NOOSA COUNCIL 24 JUNE 2021      Revision      Date       Amendment       Drawn   Checked


COVER
                                                                                                                             -                       A      18/05/2021   For Approval       MB      CS


L-01


13 NOOSA DRIVE NOOSA HEADS QLD 4567
JOB No.   CLIENT
20313     GOLDEN BREED
Log in to download the original file

SUPERSEDED OPW21_0104 - Landscaping Plans for Approval (13 Noosa Dr, Noosa Heads).pdf · 2.4 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 4 pages

Page 2

                                                                                                                                                                Proposed 'vertical garden'          1800mm high                                                2400mm high
                                                                                                  Feature local




                                                           NO
                                                                                                                                                                with wire trellis mesh on           capped and lapped timber fence                             capped and lapped timber fence
                                                                                                  boulders                                                      fence with pot plants -             to architect's specifications                              to architect's specifications
                                                                                                  300-700mm dia                                                 refer to Sheet 20313-L-03




                                                             OSA
                                                                                                                                                                                                                  135 OPH Nan
                                                                                                                                                                                                                  Plant Ophiopogon japonicus 'Nana'                                                                                                                                          PROPOSED PANDANUS
                                                                                                                                   4 WES Blu                                                                                                                                                 7 DIA Lit
                                                                                                                                                                                                                   into driveway slots (9 per slot)
                                                                                      Existing                                     9 CAR gla                                     5 WES Gre                                                                                                       2 DIA cae
                                                                                      granite paving                                                                                                                      Pergola to
                                                                                                                                   1 PAN tec                                     2 AUS dul                                architect's                                                               1 ACR imp




                                                                     DRI
                                                                                                                                     1 ACR imp                                   14 OPH Nan                               specifications                                                                8 DIA Lit
                                                                                                                                                                                    9 ZOY ten                                                                                                                                                                                                EXISTING TREE
                                                                                                                                                                                                                                                                                                                                                      2400mm high
                                                                                                                                                                                                                                                                37.015
                                                                                                                                                                                                                                                                                                                                                      capped and lapped
                                                                                                                                                                                                                                                                                                                                                                                             TO REMAIN




                                                                        VE
                                                                                                                                                                                                                                                                                                                                                      timber fence
                                                                                                                                                                                                                                                                                                                                                      to architect's
                                                                                                                                                                          Z                                                                                                                                                                           specifications
                                                                                                                                                                 Z                                                                                                                  Atlantis cells under
                                                                                                                  SIGN                                                                                                                    Stormw                                                                                                       Landscape area to be filled         PROPOSED SHRUBS
                                                                       6 LOM Sha                                                                  Z                   Z                                                                          a ter line                         driveway to engineer's




                                                                                                                                                                                                                                                                                                                                             12.295
                                                                                                                                                          Z                                                                                                                                                                                            to be free draining - refer         & GRASS TREES
                                                                       7 DIA Lit                                                   Z                                                                                                                                                specifications                                                     to Engineer's drawings
                                                                                                                         Z               Z                                                Timber bench
                                                                                                                               Z                              SW
                                                                                                                                                                AY
                                                                                                                                                                                          to architect's specifications    3 AUS dul                                                                                                     G
                                                          New driveway                                                                                  AC
                                                                                                                                                          CES                                                                                                                                                                       ARKIN                                                  PROPOSED LOW
                                                                                                                                                    Y                                                                                                                                                                            RP
                                                          to architect's specifications                                                    BIL
                                                                                                                                               IT                                                                          3 DIA Lit                                            7 JUN con                                 OO
                                                                                                                                                                                                                                                                                                                             TE
                                                                                                                                                                                                                                                                                                                                                       2 MET Lit
                                                                                                                                    D   ISA
                                                                                                                                                                                          New retaining wall
                                                                                                                                                                                                                                                                                                                        SC                                                                 SHRUBS/
          NOTE:                                                                                                                              PS                                                                               1 COR pet                                         7 AUS dul                    ARKIN
                                                                                                                                                                                                                                                                                                                   G
                                                                                                                                                                                                                                                                                                                                                       3 MET Tho                           GROUNDCOVER &




                                                                                                                         13.
                                                                                                                                       STE                                                to architect's specifications                                                                                    RP
          REFER TO SHEET 20313-L-03                               63 ZOY ten                                                                                    Timber deck                                                                                                                          OTE




                                                                                                                             706
                                                                                                                                                                                                                                                                                                  SCO
                                                                                                                                                                                                                              3 DIA Lit                                         2 BAN spi                                                              13 DIC rep                          TUFTING PLANTS
          REGARDING THE PLANTING                                  Plant Zoysia tenuifolia                                                                       to architect's               5 LOM Sha                                             2 WES GB
          OF AN X-GROUND                                          spaced at about 250mm                                                                         specifications                                    GOLDEN BREED SHOP                                                                                                                   Proposed 2m long root barrier
          PANDANUS FEATURE TREE                                                                                                                                                              11 SCA cal                                            3 DIA Lit                                      Gra
                                                                  centres into driveway slots
                                                                                                                                                                                                                  REFER TO ARCHITECT'S DRAWINGS                                                         vel                                           Local boulders 300-500mm dia
                                                                                                                                                                                                                                                                                                              pat                                                                          EXISTING LOW
                                                                                                                                                                                                                                                                                                                 h




                                                                                                                                                                                                                                                                                              Parking
                                                                                                                                                                                                                                                   9 DIA Lit                                                                                          Proposed timber bench




                                                                                                                                                                                                                                                                                              Bicycle
                                                                  (7 per slot as marked Z)                                                                                                Existing tree(s) to be retained - refer to Figure 2                                                                                B                                                             RETAINING WALL TO
                                                                                                                                                                                          on Sheet L-01. The former retaining wall and the artificial                                                                                                 (refer to Sheet 20313-L-05)
          REFER TO APPROVED                                                         45 ZOY ten                                                                                                                                                                                                                                                                                             BE REMOVED
                                                                                                                                                                                          turf are to be removed - refer to note below.           7 DOO asp                                                                                            4 FIC GI

        ENGINEERING PLANS FOR                                          Existing granite paving
                                                                                                                                                                                             9 JUN con
                                                                                                                                                                                                                                                                                                                       Mulch
                                                                                                                                                                                                                                                                                                                                                       5 LOM Sha                           PROPOSED
                                                                                                                                                                                                                                                                                                                                                                                           LOCAL BOULDERS
           DETAILS OF FRONT                                                                   7 CAS gla                                                              30.958
                                                                                                                                                                                                                                                                                                                                                       3 XAN joh
       INTERFACE AND RETAINING
                                                                                                                                                                                                                                         Provide bicycle parking space                                                                                                                     PROPOSED ROOT
                                                                                                                                                                                                                                         1.8m long with 1 rack for 2 bicycles                                                                                                              BARRIER - REFER TO
                                                                                                                                                                                                                                                                                                                  Proposed retaining walls 0.7m high max.
         WALL AROUND TREE TO
                                                                                                                                                                                                 Rendered firewall to boundary           - refer to Sheet 20313 - L04                 2 DOD tri                   to engineer's details around existing trees                              SHEET 20313-L-05
                                                                                                                                                                                                 - refer to architect's drawings

               REMAIN.
                                                                                                                                                                                                                                                                                      7 DIA cae                   - refer to Arborist's report regarding
                                                                                                                                                                                                                                                                                                                  tree protection methodology, soil and mulch                              GRAVEL AREAS WITH
                                                                                                                                                                                                                                                                                                                  Supervising RPEQ and arborist to inspect
                                                                                                                                                                                                                                                                                                                                                                                           WEED-MAT
          FIGURE 4:                                                                                                                                                           FIGURE 5:                                                                                      2400mm high                                                                                                   UNDERNEATH
                                                                                                                                                                              EXAMPLE OF CASUARINA 'COUSIN IT'                                                                                                    existing root structure of existing trees to
          ARTIST'S IMAGE OF PROPOSED 'CRAZY PAVING' WITH SLOTS FOR GROUNDCOVER,                                                                                                                                                                                              capped and lapped
                                                                                                                                                                              CASCADING DOWN A RETAINING WALL                                                                                                     ensure protection of trees and free draining
          STEPS AND LOW RETAINING WALL NEXT TO THE EXISTING TREE - REFER TO ARCHITECT'S DRAWINGS                                                                                                                                                                             timber fence to                                                                                               PLANTING IN
                                                                                                                                                                                                                                                                                                                  solution.
                                                                                                                                                                                                                                                                             architect's                                                                                                   DRIVEWAY SLOTS
                                                                                                                                                                                                                                                                                                                  Arborist is to detail retaining wall system
                                                                                                                                                                                                                                                                             specifications
                                                                                                                                                                                                                                                                                                                  around trees.



                                                                                                                                                                                                                                                                                                                       All retaining walls are to comply with
                                                                                                                                                                                                                                                                                                                       Council policy on retaining walls and
                                                                                                                                                                                                                                                                                                                       embankments on residential building
                                                                                                                                                                                                                                                                                                                       sites.

           PLANT SCHEDULE A                                                                                                        PLANT SCHEDULE A CONTINUED
           CODE      BOTANICAL NAME          COMMON NAME              POT SIZE      QUANTITY                                       CODE     BOTANICAL NAME                   COMMON NAME                                          POT SIZE        QUANTITY
           FEATURE PLANTS                                                                                                          MEDIUM SIZED SHRUBS (1 TO 3M HEIGHT)                                                                                                                                                                                     NOTE:
           PAN tec   Pandanus tectorius      Screw pine               ex-ground               1                                    BAN spi  Banksia spinulosa                Hairpin banksia                                      140mm                2
                                                                                                                                   DOD tri  Dodonea triquetra                Hop bush                                             140mm                2
                                                                                                                                                                                                                                                                                                                                                            The existing retaining wall and the
           TALL SHRUBS & CORDYLINES                                                                                                FIC GI   Ficus 'Green Island'             Ficus 'Green Island'                                 140mm                4                                                                                                    artificial turf around the existing tree in
           ACR imp   Acronychia imperforata Beach acronychia                 300mm            2                                    MET Lit  Metrosideros 'Little Dugald'     'Little Dugald'                                      140mm                2                                                                                                    the front of the shop
           COR pet  Cordyline petiolaris    Palm lily                        140mm            1                                    WES Blu   Westringia fruticosa 'Blue Gem' Coastal rosemary                                     200mm                4
           MET Tho  Metrosideros 'Thomasii' New Zealand Christmas Bush       300mm            3
                                                                                                                                                                                                                                                                                                                                                            (refer to Figure 2 on Sheet
                                                                                                                                   LOW SHRUBS, GROUNDCOVER AND GRASSES/ TUFTING PLANTS                                                                                                                                                                      2313-L-01)are to be removed.
           GRASS TREES                                                                                                             AUS dul  Austromyrtis dulcis          Midgen berry      140mm                                                       12
           XAN joh   Xanthorrhoea johnsonii Forest grass tree                200mm            3                                    CAR gla  Carpobrotus glaucescens      Pig face          140mm                                                        9
                                                                                                                                                                                                                                                                                                                                                            Existing retaining wall to be
                                                                                                                                   CAS CI   Casuarina glauca 'Cousin-It' 'Cousin-It'       140mm                                                        7                                                                                                   demolished and removed as per
                                                                                                                                   DIA cae  Dianella caerulea            Flax lily         140mm                                                        9                                                                                                   methodology recommended by
                                                                                                                                   DIA Lit  Dianella 'Little Jess'       Little Jess       140mm                                                       37                                                                                                   arborist. All works within tree critical
                                                                                                                                   DIC rep  Dichondra repens             'Kidney weed'     140mm                                                       13
                                                                                                                                   DOO asp  Doodea aspera                Prickly rasp fern 140mm                                                        7
                                                                                                                                                                                                                                                                                                                                                            root zone to be supervised by arborist.
                                                                                                                                   JUN con  Juniperus conferta           Shore Juniper     140mm                                                       16
                                                                                                                                   LOM Sha  Lomandra 'Shara'             Mat-rush 'Shara'  140mm                                                       16
                                                                                                                                   OPH Nan  Ophiopogon japonicus 'Nana' Dwarf mondo grass  140mm                                                      149
                                                                                                                                   SCA cal  Scaevola calendulacea        Blue fan flower   140mm                                                       11
                                                                                                                                   WES Gre  Westringia 'Grey Box'        'Grey Box'        140mm                                                        7
                                                                                          -
                                                                                          -                                        ZOY ten  Zoysia tenuifolia            'No mow grass'    140mm                                                     117
                                                                              APPROVED PLANS

LANDSCAPE PLAN                                                                   OPW21/0104
                                                                          NOOSA COUNCIL 24 JUNE 2021
                                                                                          -                                            NOTE:
                                                                                                                                                                                                                                                                  Revision
                                                                                                                                                                                                                                                                      A
                                                                                                                                                                                                                                                                                   Date
                                                                                                                                                                                                                                                                                18/05/2021
                                                                                                                                                                                                                                                                                                             Amendment
                                                                                                                                                                                                                                                                                                            For Approval
                                                                                                                                                                                                                                                                                                                                                        Drawn
                                                                                                                                                                                                                                                                                                                                                          MB
                                                                                                                                                                                                                                                                                                                                                                    Checked
                                                                                                                                                                                                                                                                                                                                                                      CS


L-02                                                                                                                                   Plants in hanging pots are not included. Refer to Sheet L-03

13 NOOSA DRIVE NOOSA HEADS QLD 4567
JOB No.            CLIENT                                                                                                                                                     SCALE
20313              GOLDEN BREED                                                                                                                                               1:100 @ A1 / 1:200 @ A3

Page 3

                                                       PLANTING DESIGN FOR A 'VERICAL GARDEN'
                                                        Fix 9 wire trellis mesh panels or cable                                                                    FIGURE 6:                                                                                           FIGURE 7:
                                                        trellis systems                                                                                            EXAMPLE OF POT PLANTS ON A MESH                                                                     EXAMPLE OF POT PLANTS ON A MESH
                                                        (each 900mm high x 600mm wide) onto
                                                        the fence (with a max. distance of
                                                        80mm to the fence) and supply hardy
        REFER TO SHEET 20313-L-02 FOR THE WHOLE AREA

                                                        pot plants as per Plant Schedule B.
                                                        Refer to Figures 6 and 7 as an indication    1.8m high timber fence to
                                                        for the intended effect.                     architect's specifications and to
                                                        Provide secure fixtures, light-weight        be able to hold the additional
                                                        pots and potting mix as specified            weight of the proposed pot
                                                                                                     plants             Plants below as specified on
                                                                                                                       Sheet 20313 L-02
                                                                                                                                    Pergola to architect's
                                                         9 ZOY ten                                                                  specifications




                                                                           Driveway under pergola
                                                                                                                                                                     SKETCH 1: 6 PLANTS PER PANEL

                                                         SCALE                                                                                                                                           Provide 6 cascading plants
                                                                                                                LEGEND                                                                                   per 600mm width of wire mesh.
                                                         1:50 @ A1                                                                                                                                       Retain a small distance between
                                                                                                                1.8m wide mesh                                                                           the fence and the wire mesh
                                                                                                                structures                                                                               (up to 80mm) to avoid too much
                                                                                                                                                                                                                                                                       FIGURE 8:




                                                                                                                                                                                            900mm high
                                                                                                                                                                                                         moisture building up.
                                                                                                                                                                                                         Fix planting containers securely to                           ALTERNATIVE IDEA:
                                                                                                                                                                                                         the mesh, for example with
                                                                                                                                                                                                         'Whites Outdoor 200mm Black                                   FIX HANGING BASKETS DIRECTLY TO THE FENCE.
                                                       PLANT SCHEDULE B - 'VERTICAL GARDEN'
                                                                                                                                                                                                         Potholders'.                                                  CHOOSE MOUNTED RINGS THAT MATCH THE
                                                                                                                                                                                                                                                                       SIZE OF THE SUPPLIED POTS.
                                                       CODE         BOTANICAL NAME                       COMMON NAME               POT SIZE     QUANTITY                                                 Alternatively, install a sturdy
                                                                                                                                                                                                         bamboo-mesh.
                                                       PLANTS IN LIGHT WEIGHT POTS / PLANTERS                                                                             600mm wide
                                                       CA           Aeschynanthus micranthus             Lipstick vine             140mm               3
                                                       CL           Cissus rhombifolia 'Ellen Danica'    Cissus 'Ellen Danica'     140mm               9
                                                       CA           Chlorophytum comosum                 Spider plant              140mm               3
                                                       CA           Dichondra argentea 'Silver Falls'    Silver nickle vine        140mm               9
                                                       NF           Doodia aspera                        Prickly fern              140mm               3
                                                       CA           Hoya carnosa                         Wax flower                140mm               9
                                                       CA           Lobelia trigonocaulis                Forest Lobelia            140mm               3
                                                       CA           Neomarica gracilis                   Brazilian Walking Iris    140mm               9
                                                       CL           Piper hederaceum var. hederaceum     Native pepper vine        140mm               3
                                                       CA           Sedum morganianum 'Burrito'          Donkey Tail               140mm               3           FIGURE 9:                                                    FIGURE 10:
                                                       CA= Cascading plant, CL= Climber, NF= Native drought tolerant fern
                                                                                                                                                                   CISSUS 'ELLEN DANICA'                                        HOYA CARNOSA
                                                                                                         TOTAL PLANTS IN LIGHT WEIGHT POTS: 54

                                                       Note: Availibility of proposed plants as listed above to be determined at planting time.
                                                       Replant all plants into the same kind of pots using a good quality, light-weight potting mix                                                                                                                       MAINTENANCE:
                                                       (refer to note below).                                                                                                                                                                                             After the initial installation of the 'vertical garden' and daily watering according to the needs of each
                                                       Fix securly to the wire mesh in a random pattern. Ensure sufficient watering and good drainage to avoid                                                                                                            species it will be the responsibility of the owner to maintain and care for the pot plants
                                                       any water-logging in pots.                                                                                                                                                                                         (watering, occasional liquid fertilising and replacement of plants or re-potting as required).
                                                       Pots could be fixed with wire hooks, wall grid plant hangers or aluminium pot clips hooks
                                                       - refer to examples on this sheet.

                                                       POTTING MIX FOR PLANTS IN LIGHT WEIGHT POTS                                                                 Note: Vigorous climbing plant,                               Note: Drought tolerant
                                                                                                                                                                   best in shade                                                native plant
                                                       Supply a potting mix that is suitable for 'vertical gardens', for example 'Rocky Point Green Wall Mix',
                                                       or mix a high quality potting mix complying with Australian Standards with coarse perlite, humus and coir
                                                       (with a min. of 70% potting mix containing controlled release fertiliser and a soil wetting agent ).
                                                       Special potting mixes may be used for succulents such as Sedum species.



                                                                                                                                                                                                         -
                                                                                                                                                                                                         -
                                                                                                                                                                                                                                               Revision      Date           Amendment                 Drawn       Checked

'VERICAL GREEN WALL' & PLANT SCHEDULE B                                                                                                                                               APPROVED PLANS
                                                                                                                                                                                         OPW21/0104
                                                                                                                                                                                  NOOSA COUNCIL 24 JUNE 2021
                                                                                                                                                                                                         -
                                                                                                                                                                                                                                                   A      18/05/2021       For Approval                 MB          CS


L-03


13 NOOSA DRIVE NOOSA HEADS QLD 4567                                                                                                                                            SCALE
20313                           GOLDEN BREED                                                                                                                                   AS SHOWN

Page 4

        GENERAL PLANTING NOTES                                                                                                                                                                PLANTING NOTES FOR THE PROPOSED PANDANUS FEATURE TREE
        1. PLANT QUALITY                                                                                                                                                                      The proposed exground Pandanus feature tree is to be in a healthy condition and a good structural form.
        All plant stock is to be be to the scheduled nomenclature, well formed, hardened off nursery stock.                                                                                   When transplanting the Pandanus, the hole must be dug to a width and depth greater than that of the
        They are to be container grown in potting mixture with a healthy root system and not pot bound.                                                                                       rootball by 300mm. A sandy soil mix shall be added to the hole prior to placement of tree. The tree is to be
        All pots shall be free of weeds and plant stock is to be free from living insects, pests and disease. All                                                                             craned into position ensuring that any slings used do not compress the bark tissue. The tree to be located
        plants are to be fully sun or shade hardened-off to suit their on-site growing position for a                                                                                         into position with the soil level established at 150mm above natural ground level.
        minimum period of 6 weeks.
                                                                                                                                                                                              During installation a water probe is to be used to ensure all sandy soil content is evenly distributed around
        2. ADVANCED TREE NOTES
                                                                                                                                                                                              the root ball negating any air pockets and consolidation of the soil mix. A soil berm is to be constructed just
        All advanced trees 25L or greater are to be certified as either Natspec or AS2303 compliant.
                                                                                                                                                                                              outside the trees root ball and left intact for the 12 months watering and maintenance program.
        Contractor to sight and supply certification to superintendent prior to accepting trees from the
        nursery. Contractor is to review all tree stock at unloading and prior to planting to ensure the                                                                                      Refer to Details 1 & 2 below regarding the typical planting and guying.
        following: Trunk is not burried below flare in trunk at top of roots; There is no sign of root girding;                                                                               A regular weekly and then monthly watering program must be undertaken which fills inside the soil berm
        Tree is self supporting; Tree is of good form and health; When bag is removed roots are not circling                                                                                  along with crown watering during the establishment period. The root hormone Auxinone is to be applied at
        or pot bound. Trees that fail these criteria should not be planted and are to be returned to nursery.                                                                                 2 week intervals for a period of 3 months to assist in root development. Liquid fertiliser is to be added at
        Trees are to be planted 20-30mm above finish level to allow for settling. Rip side of root ball prior to                                                                              alternative weeks during the 3 month period and monthly thereafter.
        planting to loosen roots.
        3. IMPLEMENTATION                                                                                                                                                                     During the 12 month establishment period the condition of the Pandanus trees will be monitored for
        Ensure all planting procedures result in healthy plant species within the prevailing soil, climatic and                                                                               foliage and root development as well as pest and disease.
        management environment of this project. Refer to Details 1 to 3 of the landscape design.                                                                                              All the above works are to be carried out in accordance with horticultural industry best practices and
        The following minimum is expected:                                                                                                                                                    overseen by a suitably qualified and experienced arborist or horticulturist familiar with the requirements
                                                                                                                         FIGURE 11:
        - Excavate a hole for each plant twice the diameter of the rootball and 100mm deeper than the root                                                                                    needed to achieve success with large tree transplant operations. A NATSPEC Certificate shall be issued by a
        ball. Break up the base of the hole to a further depth of 100mm and loosen the sides of the hole.                EXAMPLE OF A STATELY
                                                                                                                                                                                              qualified arborist to Council declaring the Pandanus are free from disease, in good general health and
        - Remove the plant from the container, tease out roots and place in final position, ensure it is central         PANDANUS TREE                                                        vigour and free from injury.
        and plumb. Ensure the root ball is level with the finished surface of the soil surrounding the hole or           AS A FEATURE PLANT
        bed.
        - Ensure correct placement of fertiliser and/or water retention additive as per manufacture's
        specification and requirements.
        - Backfill with topsoil as specified. Lightly tamp and water thoroughly to eliminate any air pockets.
                                                                                                                               01        DETAIL 1: TYPICAL GUYING                                                                02
                                                                                                                                                                                                                                       DETAIL 2:
        Ensure that topsoil is not placed over the top of the rootball or where base of trunk flares.
        Thoroughly water plants immediately after planting and at such times during the contract period as                    L-05       OF PALMS AND PANDANUS TREES                                                            L-05   TYPICAL PLANTING OF X-GROUND PLANTS
        required. All plant stock will require a minimum of 10ltrs of water at the time of planting.
                                                                                                                                                                                                                                       Notes:
        Collect all empty plant containers daily during planting operations and remove from site.                                                                                                                                      - Place the rootball on a firmed base to achieve required FSL.
                                                                                                                                                                                                                                       - Thoroughly water the root ball immediately after planting.
        Keep soil level and flush so that watering will not not push soil in around trunk of tree.                                                                                                                                     - Number of stakes will vary with pot size. Refer plant schedule.
        Any watering berms are to be made of mulch only.                                                                                                                                                                               - Cultivate sides of excavated hole 50mm.
        Do not vary the plant locations from those specified on the drawings unless otherwise directed by
        the Superintendent. Should it be necessary to vary the locations and spacing for any reason,
        immediately apply for directions by the Superintendent.
        4. PLANT ESTABLISHMENT                                                                                                                                                PALM COLLAR:
                                                                                                                                                                                                                                       Deep watering pipe
        The Establishment Period commences at the date of Practical Completion of Works.                                                                                      Guy ropes tied to palm
                                                                                                                                                                              collar. Refer Inset Detail A
                                                                                                                                                                                                                                       Raise plant 100mm above
                                                                                                                                                                                                                                       finished surface level.
        During the Establishment Period maintain best horticultural practices including (but not limited to)                         INSET DETAIL A                                                                                    Mulch - pull away from
        the following items where required: watering, weeding, fertilising, pest and disease control,                                PALM GUYING:                                                                                      base of trunk
                                                                                                                                     Fix Palm Collar as                       TURNBUCKLE:
        mulching, pruning, rubbish removal and keeping the site neat and tidy. Rectify defects that become                           specified to                             Refer notes.                                             Form an earthen basin
                                                                                                                                                                                                                                       around base of plant.
        apparent in the works under normal use.                                                                                      manufacturers
                                                                                                                                     recommendations. Guy                                                                              Topsoil blend
        5. PLANT REPLACEMENT                                                                                                         at 2/3 height of trunk.
                                                                                                                                                                              FIXING:
        Replace failed or damaged plants. This does not include vandalised or stolen plant material - these                                                                   Refer Notes.




                                                                                                                                                                                                                                                                                                           300
        will be replaced prior to practical completion or at the superintendents direction.                                                                                                                                            Water retention
                                                                                                                                                                                                                                                                                                                           1
                                                                                                                                                                                                                                       additive
        6. MULCH                                                                                                                                                                                                                       Fertiliser: Do not
                                                                                                                                                                                                                                                                                                                       1

        All mulch is to be free of deleterious or extraneous matter such as soil, weeds, rocks, and twigs. The                                                                                                                         allow contact with
                                                                                                                                                                                                                                       roots.                                        width (w)
        finish level of the mulch is to be level with the finish level of all adjacent surfaces after settlement




                                                                                                                                                                                                                                                                                                                 150
                                                                                                                                                                                                                                       10-20mm
        allowances of the topsoil and mulch. Ensure all mulch is placed clear of plant stems to avoid rotting                                                                                                                          drainage gravel
        at ground level. Mulch is to be Hoop Pine Curls or chipped forest mulch (a combination of wood,                                                                                                                                Sub-soil drain - refer detail.
        leaves and bark) or approved equal. Refer to the arborist's report and notes on Sheet 20313-L05
                                                                                                                          NOTES:                                                                                                       Rootball anchor
        regarding the mulch for the existing trees to remain.                                                             All metal work to be hot dipped galvanised.                                                                                                                  2xw
                                                                                                                          Turnbuckles to be HDG, eye to eye type, 8mm dia. with lock nut.
                                                                                                                          All guy ropes are to be tensioned evenly to ensure pandanus is maintained
                                                                                                        -
                                                                                                        -
                                                                                                                          in an upright position.                                                                                      400ltr to X-Ground
                                                                                                                                                                                                                                       SCALE 1:20 @ A1    scale 1:20
                                                                                                APPROVED PLANS            Wire guy rope to be 5mm dia. and secured with HDG 'D' clamps.                                                Note: The feature tree Pandanus tectorius
        PLANTING NOTES FOR THE 'VERTICAL GARDEN':                                                  OPW21/0104             Rope to be fixed with Duckbill Anchors.
                                                                                            NOOSA COUNCIL 24 JUNE 2021    Duckbill Tree Anchors to be appropriate size as recommended by manufacturer.                                 to be certified free of any pests and diseases.
        REFER TO SHEET 20313-L-03.                                                                      -

                                                                                                                                                                              SCALE 1:10 @ A1


                                                                                                                                                                                                             Revision      Date         Amendment                       Drawn         Checked

PLANTING NOTES                                                                                 SCALE FOR DETAILS:
                                                                                               AS SHOWN
                                                                                                                                                                                                                 A      10/05/2021     For Approval                       MB            CS


L-04


13 NOOSA DRIVE NOOSA HEADS QLD 4567                                                                                                                   FIGURE 12:
                                                                                                                                                      EXAMPLE OF THE GUYING OF AN
20313           GOLDEN BREED                                                                                                                          ADVANCED PANDANUS AFTER
                                                                                                                                                      REPLANTING IN A NEW LOCATION

Page 5

         SPECIFICATIONS / EXTENT OF WORKS                                                      SPECIFICATIONS / GENERAL NOTES                                                                                   MATERIALS AND FINISHES (CONTINUED)
         Contractor to ensure they have the latest issue of the documents prior to tendering   1. FALLS:                                                                                                        Topsoil:                     For new garden beds. Also refer to Detail 2.
         and construction. Where there is conflicting information, contact the Landscape       Grade all turf and planting areas evenly away from structures and towards legal
         Architect.                                                                                                                                                                                             Garden edge:                 100x38mm Treated pine garden edging
                                                                                               drainage points of discharge. Ponding is not accetable.
                                                                                                                                                                                                                                             surround with 500x38x38mm treated pine pegs at
                                                                                                                                                                                                                                             1200mm centres.
                                                                                               2. SOIL:
         LANDSCAPE WORKS ARE TO INCLUDE THE FOLLOWING:                                         All soils (both the site topsoil and imported topsoil) to comply with AS 4419.                                   Gravel and weed-mats:        To areas as indicated on Sheet 20313-L-02.
                                                                                               Topsoil for garden areas to be a min. 300mm depth. Topsoils are to be tested for                                 Gravel area                  One bicycle rack (stainless steel hoop) for 2 bicycles
          1. Co-ordination with other Trades and conduit installation where applicable         horticultural suitability and receive appropriare amelioration if required. All topsoil
          2. Excavation and Drainage of planting areas                                                                                                                                                          and 1 bicycle rack           has to be installed.
                                                                                               must be free from noxious weeds, rocks, roots, nut grass, rubbish or other deleterious                           with concrete footing        Allow 1.8m space for the length of a bicycle (horizontal
          3. Topsoil - Supply and incorporation                                                material. Place all topsoils in the areas directed and specified. Prevent excess
          4. Edging to planting areas                                                                                                                                                                                                        parking) and 1m space for the width of 2 bicycles.
                                                                                               compaction during construction works. Stripped site soil needs to be stored in piles                                                          Refer to Figure 5 for an example of a hoop.
          5. Shaping of garden areas                                                           no greater than 2m high x 3m wide.
          6. Containerised Plant Material - Supply and installation
          7. Supply and installation of a "vertical garden" - refer to Sheet 20313-L-03                                                                                                                         Stakes / guys                Where necessary for tree and Pandanus planting
                                                                                               3. WEEDS:
          8. Organic Garden Mulch - Supply and Spread                                          Eradicate all weeds with an approved herbicide as per manufacturer's                                             Retaining walls              Refer to Arborist's report and "Tree Protection
          9. Install gravel path & bicycle hoop with concrete footing                          recommendations.                                                                                                 for 2 trees in the back      Methodology"by Kurt Brown,
         10 Install drainage material and weed-mats as required
                                                                                                                                                                                                                garden                       dated 22/02/2021,
         11 Install root barriers as per engineer's details                                    4. MULCH FOR NEW PLANTING AREAS:                                                                                                              and to the Development Layout Plan
         12 Supply and install a timber bench                                                  Supply and place Hoop Pine Curls or chipped forest mulch (or approved equal) in a                                                             by 360 Civil Consulting.
         13. Watering as required according to rainfall, weather and soil conditions           75mm thick layer evenly over all garden beds. Mulch to be free from rubble and
         14. Maintenance of landscape works: 12 months for general landscaping works           rubbish, soil, weeds and sticks. Keep mulch 75mm min. away from stems of plants and                              Root barriers for existing   Refer to Arborist's report and "Tree Protection
             (not including the "vertical garden").                                            150mm away from trees to avoid collar rot.                                                                       trees on site                Methodology"by Kurt Brown,
                                                                                                                                                                                                                                             dated 22/02/2021,
                                                                                               5. SOIL / MULCH FOR EXISTING TREES:                                                                                                           and to the Development Layout Plan
                                                                                               Refer to Arborist's report by Kurt Brown, dated 22/02/2021, regarding the existing                                                            by 360 Civil Consulting.
                                                                                               trees. Remove all material and non-historic soil from the Tree Protection Zone.
                                                                                                                                                                                                                Root barriers for the        Install root barrier near the proposed Atlantis cells as
        MATERIALS AND FINISHES                                                                 Supply mature forest blend mulch to a depth of 150mm minimum on the Tree
                                                                                                                                                                                                                proposed hedge of            indicated on Sheet 20313-L02.
                                                                                               Protection Zone on all trees.
        'Vertical Garden':             Refer to Sheet 20313-L-03 regarding the proposed                                                                                                                         Metrosideros                 Refer to supplier's installation guidelines.
                                       'vertical garden' along the fence line                                                                                                                                   'Thomasii' in the back
                                                                                               6. PLANTS:
                                       including proposed structures, all necessary timber                                                                                                                      garden
                                                                                               All plants to be healthy, robust and free of any pests and myrtle rust. Refer to sheet
                                       screws and other fixtures,                              20313 - L-04 for further planting specifications.                                                                Boulders for front garden    Supply and install 3 local boulders in the front garden
                                       pots, potting mixes and fertiliser.
                                                                                                                                                                                                                                             in a natural looking way in approximate locations as
                                                                                               7. RIVER GRAVEL AND STEPPING STONES:                                                                                                          shown on Sheet 20313-L-02.
                                                                                                                                                                                                                                             Boulders to be 300 to 700mm diameter and placed firmly
                                                                                               areas where indicated. If any stepping stones are supplied, they are to be set firmly in                                                      into the ground (dug in to one third.)
                                                                                               mortar and spaced evenly, with a comfortable step length.
                                                                                               Grade subbase evenly away from building at a minimum grade of 1:20.                                              Boulders for back garden     Supply and install 3 local boulders in the front garden
           03       DETAIL 3: TYPICAL GARDEN BED                                                                                                                                                                                             in a natural looking way in approximate locations as
          L-05                                                                                 8. FENCES AND PERGOLA:
                                                                                                                                                                                                                                             shown on Sheet 20313-L-02.
                                                                                               To be constructed by others.
                                                                                                                                                                                                                                             Boulders to be 300 to 500mm diameter and placed firmly
                                                                                                                                                                                                                                             into the ground (dug in to one third.)

            FSL                                                                                                                                                                                                 Bench in                     Supply and install one timber bench. Refer to Figure 6
                                                            Mulch                                                                                                                                               back garden                  as example. Footing as specified by the supplier.
                                                                                                                                                                                                                                     B
                                                            - to 100mm depth                                                                                                                                    (marked 'B')                 Timber bench may need to be stained with an approved
                                                                                                                                                                                                                                             outdoor oil as specified by the supplier.
                                                           Soil blend or site topsoil
                                                           - to 300mm depth

                                                           Cultivated subgrade - to
                                                           150mm depth




                                                            Notes:
           Garden bed profile scale                         -Refer Materials & Finishes
           1:10 @ A1                                        Schedule for fertiliser                                                                                                                       FIGURE 14: EXAMPLE OF A
                                                            application requirements                                                                                                                      'COURTYARD SEAT' BY GOSSI
                                                                                               FIGURE 13: EXAMPLE OF A BICYCLE                                                                            PARK & STREET FURNITURE
                                                                                               HOOP BY MOODIE PRODUCTS
                                                                                                                                                                                        Revision      Date                  Amendment        Drawn      Checked

LANDSCAPE SPECIFICATIONS                                                                                                                                                                    A      18/05/2021              For Approval        MB         CS


L-05


13 NOOSA DRIVE NOOSA HEADS QLD 4567                                                                                             -
                                                                                                                                -
                                                                                                                       APPROVED PLANS
                                                                                                                          OPW21/0104
                                                                                                                                                             SCALE
20313            GOLDEN BREED                                                                                      NOOSA COUNCIL 24 JUNE 2021
                                                                                                                                -
                                                                                                                                                             AS SHOWN