07/1993 - Op Works - landscaping, carparking, access, frontage works, stormwater, erosion & sediment control [As Published] · 142007.1993
Rev
HYVDRAULIGES
HA
LOTS 9 & 10 GRANT STREET
NOOSA HEADS
FOR
MATTEW & JOANNE EXLEY
GENERAL NOTES
Water Supply and Sanitary Drainage has been designed and shall be constructed in
accordance with the Q'ld Standard Sewerage tow, Q'ld Standard Water Supply Law,
the Nationa! Plumbing and Drainage Code AS 3500., all relevant Australian Standards,
and the requirements of the Local Authority.
These Drawings are diagrammatic only and shall be read in conjunction with all relevant
Architectural and other consultants drawings and specifications and other written
instructions that may be issued during the course of the contract.
Any discrepancies sholl be referred to the supervising officer for decision before
proceeding with the work.
Contractor shall verify all fixture locations, invert levels, surface levels, and
cover to pipes are correct and obtainable prior to commencement of the work.
The exact location of existing, and proposed services, shall be verified with
the relevant Authority, or other trades as applicable.
Fire stop collars to be used on all plastic pipework penetrating fire resistant
construction.
SANITARY DRAINAGE
Underground pipework shall be 100 dia. PVC DWV, min grade 1:60 U.N.O.
Suspended Pipework shal! be PVC class Dw.
Trade waste pipework to grease trap suspended shall be “Coesprene” or
HOPE. Underground shall be vitreous clay or HDPE.
Trade waste pipework to oil separator shall be HDPE, or Vitreous clay with
“Nitrite” rubber rings.
CLeanouts or inspection openings brought to surface in poved or concrete
areas, or within buildings to have brass caps.
STORMWATER DRAINAGE
Underground pipework shail be 100 dia PVC class SW min grade 1:100 U.N.O.
Downpipes shal} be 100 Dia PVC class SW.
Rainwater outlets (RWO) ond planter outlets (PO) shall be “Gatic Wade” or similar,
with membrane clamp where required.
WATER SUPPLY
Pipework shall be copper tube type B. UNO. Water supply pipework shall be 20 dia
U.N.O. Except one fitting only may be 15 dia. mox. length 3000 mm.
Hot water pipework shall lagged.
Hot water recirculoting lines to be insulated with 20mm "Armafiex” or similar.
Provide tempering valves on hot water to personal hygiene fixtures.
Underground copper pipework shall be "Kemlagged” or otherwise protected.
Underground pipework not under concrete slab may be polypipe class PN20.
one size larger than shown.
Exposed pipework in amenities areas, shall be chrome plated.
Where water meters are installed within tennancies, provide remote readout
adjacent to Electrical meters, or in a position as indicated by the Architect.
BACKFLOW PREVENTION
Provide hose connection vacuum breakers to all hose cocks
Provide RPZD to any irrigation connections.
COVERS & FRAMES
Covers subject to vehicular traffic to be 535 dia, cast iron, medium duty UNO.
Covers in grassed or conc. areas to be 535 dia. cast iron, concrete infil! light duty.
Covers in paved areas to be 600 sq. Infill to match paving pattern.
Covers in tiled areas to be as for paved areas with brass edging.
Concrete infill covers to be stamped “SWD” or "SEW" as appropriate.
Covers & Frames to be "Faston” or equal approved.
GRATINGS
Gratings for storm water to be “faston, Gatic” or approved equal.
Duty to match manufacturers recommendations for loading condition.
Trench grate to be transverse bar.
Floor waste grates to be chrome plated brass
LEGEND
Non potable water 4 Diameter
Existing water C.0.8, Cleanout to surface
Existing sewer CJ Capped junction
Existing storm water cv Conrol valve
Existing house drain cs Cleaners sink
Sanitary Drainage cw Cold Water
Vent Pipe DAP Duct access panel
Cold Water bev Double check valve
Een Eccentric Enlarger
Hot water . Elev Dge Evevated Drainage
Storm Water Drainage Enl Enlarger
Fire FC False ceiling
Agi Drain FH Fire Hydrant
FHR Fire hose reel
. FFL Finished floor jevel
Cold Woter Riser FU Fixture units
a]
Down Pipe GIT Grease Interceptor trap
@y=— 9 Stack GP Gully pit
. GMH Gully Man Hole
Ce) o Vent Pipe gv Gate valve
o HW Hot water
Group vent HCB House connection branch
) © Educt vent HD House drain
®) ° HL High Sevel
@ Induct vent Ic Inspection Chamber
Ox") ° Hot water riser IL Invert Level
Fire Dropper io inspection opening
. . jos Inspection Opening to Surface
0 Fire Riser K&C Kerb & Channel
8} 6 * MH Monhole
8°) Non potable riser NRV Non return valve
_. — t t PB Path box
Wi) water meter PLY Pressure limiting valve
PO Planter outlet
v Valve RPB Reai Property Boundary
a
— he Hose Cock REDD Real Property description
. educe Pressure Zone device
ee een Eccentric enlarger RWO Rain water outlet
--—<ch-= en Enlarger RWH Rain water head
sD Sanitary Drainage
@) ORG Overflow Relief Gully SL Surface Level
34 Squore
lo wo Water s/t Safe Tray
Closet swd Storm water drain
. t/td Trapped Tundish
sk Sink TG Test gate
td Tundish
iT Laundry tub Tah Trench grate transverse bar
. TG Trench grate longitudinal bar
wm Washing TMV, Thermostatic mixing vaive
Machine Vv Tempering valve
EWG Floor Waste u/g Underground
gully u/s Under’ slab
. U.n.o. Unless noted otherwise
Bn Basin WS Water supply
Bath
Shr Shower
FHR Fire Hose Reel C)
cs Cleaners Sk
HWS Hot water system
Bulje> of
PROPOSED
DEVELOPMENT
enity Ct
-
eT
L..
Ternpering valve
max 50°C
NP
NP eee NP
mark “NON POTABLE’
Irrigation
Note:
NP npl
z
o
tps. |
STORMWATER HARVESTING STRATEGY
Attungg Hts
Angier St
Viewland Br
Dishwasher
Provide mosquito safe
overflow and infiow screening
Slow leak
Pump
HC
stormwater
system
to be determined
zone
Stormwater
pit
Harvesting
Roof water
Sludge valve
optional
limiting volve within
path box
Capilary bleed tubing
discharge point from
first flush device, or
in garden 1m away
Rainhead with leaf!
screen and mosquito
screen if applicable
|
floating ball
valve
Mox SO0OkPa pressure!
RPB Towns
Lots 9 & 10 on SP1/79879
DRAWINGS
1743
1743-0-1
— GENERAL NOTES & LEGEND
— STORMWATER OPERATIONAL WORKS
Pollution Control Management Plan (PCMP):
1. To be responsibility of Management
2. To list all in flow filtering devices like leaf eaters
at DP’s and other filters
3. To keep and maintain a log of cleaning
4. To clean devices including first flush storage tank
—as to manufactures specification
—minimum quarterly, but monthly in rainy season
—after each major rainfall event
To inspect and clean tanks minimum once yearly
To install and maintain pump and fixtures for
reuse/watering/irrigation as to manufactures specification
ao
Description
Hl
Issue Notes Date
For Development Approval
For Construction
s Constructed
TO85r#
CATCHMENT AREAS
(TOTAL OF BOTH
PROPERTIES)
Construction Hydraulic
contact: Reinhold Koenning MicAust RPEQ No 7023
PO Box 1176
Buddina QLD 4575
email: [email protected]
www.conh
PH: 5444 8645
FX: 5444 8224
MATTEW & JOANNE EXLEY
ARCHITECT“ OUTHERN CROSS
D N & DKA N
PROPOSED RESIDENTIAL
LOTS 9 & 10 GRANT STREET
NOOSA HEADS
DRAWING TITLE:
Note: PROJECT:
All kitchen, laundry & bathroom fittings and toilets
to comply with the AAA Water Conservation Rating
System as defined by AS/NZS6400.
Provide flow restrictor valves where necessary
to taps and shower roses. The flow shall not
exceed a maximum of 9L/min
GENERAL NOTES &
LEGEND
Sel ear e |
: iF
1743 )
RPD:— Lots 9 & 10 on SP179879
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1993 - Op Works - landscaping, carparking, access, frontage works, stormwater, erosion & sediment control [As Published]Related documentApplication case desk ↗