07/1993 - Op Works - landscaping, carparking, access, frontage works, stormwater, erosion & sediment control [As Published] · 142007.1993
(>
VY
£ a
a _—
i —
+ Qo —
a 550 of/hang —
1800 o/hang —
+—# +——___# — 600 ofhang
ALUMINIUM FRAMED WINDOWS COLORBOND CUSTOM ORB TIMBER PURLINS AND RAFTERS _—
AND DOORS FIXED TO ROOF SHEETING TO MANUF. @ 900 CRS TO ENGINEERS, —_—
MANUFACTURER'S SPEC AND SPEC FIXED TO N3 DESIGN AND DETAIL.
N3 RATING NON-CYCLONIG RATING PBO LINING TO U/SIDE OF
HWD RAFTERS - SEALED AND RAFTERS ¢—_—___—_———_ HWD RAFTERS - SPANRIB ROOF SHEETING TO
PAINTED WHERE EXPOSED SEALED AND PAINTED MANUF. SE le N3
NON-CYCLON!
gm ABOVE NGL a
PITCH + —
JOINERY _ | oT
| UNIT 2 : 250mm GRATED DRAIN
| LIVING DINING et CONCRETE
| DRIVEWAY
Ht 1000mm GLAZED 7 2
BALUSTRADE B
TIMBER FRAMED FLOORS ae
: TO ENGINEERS DETAILS :
UPPER FLOOR @ RL 23.84 | : i +H He page Ga FEE ID RR BRT So ip
2 * —r Pp pl ee a nnn = = Cae LEO
eee 7 | Wh DPC UNDER TIMBER : [ “EP: ss : we : w .
a Wak ene ot FRAME & SLAB. . her
JOINERY - . Vg EY _ _ CONTINUE CEILING Det
ao wpe SP ee LINING UNDER SLAB ean
i RC BLOCK WALL TO oe
ENGINEERS DESIGN wey:
| AND DETAIL. PBD piv
BED 1 LINING TO WALL po oo
| BED 2 ae ee II OX SYP NYNYNYN
TIMBER FRAMED pte . CLAN CCAS
FLOORS TO DPC TO MANUF. we TAY SS ~~
LOWER FLOOR @ RL 20.94 ENGINEERS DETAILS SPECIFICATIONS I. G CY 7 ENGINEERS DESIGN AND
@RL 20, 7 KES SY -ERRACE SLAB even
@RL 20.89
RC SLAB, BLOCK RETAINING WALL
AND FOOTING TO ENGINEERS DESIGN
AND DETAIL.
ar H/
MN) ig
ANAS!
HWD TIMBER DECK WITH HWO
SHOTEDGE DECKING AS PER orem te Wy To AG. DRAINAGE PIPE. MIN. 100mm
| es vr Xx KK 90 X 19mm SHOTEDGE HWD
OY KS ~ S TIMBER BATTENS BETWEEN
NEIGHEOUR FENCING | RRA KS» 7, » We, » BLOCK WALLS
> f
NGL AT SECTION
; 75 x 75 SHS POST A
VCS
VRRIRIRISINS y I
FIRE RATED PARTITION WALL RC FOOTING STO ENGINEERS
TO MIN. FRL 60/60/60. DESIGN AND DETAIL.
SELECT CR FINISH
SECTION A-A - TYPICAL
SCALE 1:50
Southern Cross a
D e S I n & D r a ft | Nn g These drawings have been prepared for Building Permit application only. It is the Builders/owners responsibility
to further interpret the design and drawings to detail the project for construction.
Comme rcial * Industrial * residentia building . Builder shail verify all ‘acations of services, dimensions and jevels prior to construction.
Suite/4 80 Sixth Ave Maroochydore Gesigners' Setout dimensions on site shall be confirmed by builder before commencement of construction and ordering.
Ph: 5479 5313 Fax: 5479 5314 asecciation of Amend setout if necessary to comply with council by-laws and setback distances.
QBSA Lic 1110414 queensiand Ine. During construction the building shall be maintained in a stable condition and no part shall be overstressed.
ee
£
—_
£
a
2
a
GRANT STREET
RL 24.754 Ri 24.008 Ri 24.767
RL 24.634 — RL 24.630
My RL 24.027 oo \ \ XS XS XY RX Sx
: ROR NININ NINE
Sot
CARPORT SLAB @ RL 23.79
190mm RC BLOCK RETAINING
WALLS AND FOOTINGS TO
ENGINEERS DETAILS.
AG. DRAINAGE PIPE. MIN. 100mm
AMENDMENTS
27.08.07 Raised carport slab RL
& added 400mm step in slab.
Updated driveway profile
19.09.07 Moved Unit 800mm towards rear
boundary.
Raise Unit 200mm and lower
carport slab 250mm.
Updated driveway profile.
Changed truss roof to rafter
and purlins with raked ceiling.
Changed wall between Bed 2 &
Terrace from timber frame to
RC block.
PROJECT INFORMATION Title: SECTION A-A
Drawn: JL
provectTvpe | AESDENTIAL | [Signed
LOT NUMBER: Date: 19/9/07
STREET: Scale: 1:50_Al 40f8
SUBURE:
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1993 - Op Works - landscaping, carparking, access, frontage works, stormwater, erosion & sediment control [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.