COLOUR 3

Unit 2

4
poner RENDERED FC SHEETING FIXED TO

70mm TIMBER F
COLOUR 3

LOWER FLOOR@RL 20.96

100 X 100 HWD TIMBER POSTS.
COLOUR 3

LOWER FLOOR @ RL 20.94

TIMBER FRAMED STAIRS WITH __|
SS WIRE BALUSTRADE

 

    

SCALE 1:100

Unit

COLORBOND CUSTOM ORB ROOF
SHEETING TO MANUF. SPEC FIXED
TO N3 NON-CYCLONIC RATING.

COLOUR 1

i
a!

     
  

   
 

  
   
  

ELEVATIONA

  

 

 

RAME.

N3 RATING

1 Unit 2

RENDERED FC SHEETING FIXED
TO 70mm TIMBER FRAME.
COLOUR 3

 
 
 
  
 
      

    
   

 

 

FIRE RATED PARTITION WALL
TO MIN. FRL 60/60/60.

-— 1000mm GLAZE
BALUSTRADE

SELECT CR FINISH. COLOUR 3

SCALE 1:100

Sheet roof, gutters
& downpipes.
Custom Orb
cladding

Timber batten
screens

Rendered sheeting
, walls & exposed
timber

(truss tails, posts,

ELEVATION C

COLORBOND
"Windspray”

or equal colour

DULUX

; "Ferry"

or equal colour

OULUX
"Clay Bake”

or equai colour

 

beams & battens)

 

Schedule of External Colours

= Foe

ul bition a

 

“er

      
    
 

 

 

 

 

   

 

90x 19mm SHOTEDGE HWD TIMBER
BATTEN SCREEN. COLOUR 2

SUSPENDED RC SLAB TO
ENGINEERS DESIGN AND DETAIL

RC BLOCK WALLS WITH SELECT
GR FINISH. COLOUR 3

SOLAR HOT WATER SYSTEM AS
PER BUILDER'S CONTRACT.
POSITION TO BE VERIFIED

COLORBOND FASCIA AND
GUTTER. COLOUR 4

+—— ALUMINIUM FRAMED WiNDOWS

AND DOORS FIXED TO
MANUFACTURER'S SPEC AND
N3 RATING

COLORBOND CUSTOM ORB
CLADDING TO MANUF. SPEC FIXED
TO N3 NON-CYCLONIC RATING.
COLOUR 1

  
 

 

|

|

Line O

COLORBOND CUSTOM ORB ROOF
SHEETING TO MANUP. SPEC FIXED
TO N3 NON-CYCLONIC RATING.
COLOUR 1

     
        
  
 
  
 
 
 
  
 
 
 
 
  
   
  

Property

ef

ALUMINIUM FRAMED WINDOWS AND
DOORS FIXED TO MANUFACTURER'S
SPEC AND N3 RATING

RENDERED FC SHEETING FIXED TO
70mm TIMBER FRAME.
HWD RAFTERS AND BATTENS - SEALED AND COLOUR 3

PAINTED WHERE EXPOSED. COLOUR 3

GRANT STREET

ly

|
|
/

COLORBOND CUSTOM ORB ROOF
SHEETING TO MANUF. SPEC FIXED
TO N3 NON-CYCLONIC RATING.

 

 

RENOERED FC SHEET FIXED TO
70mm TIMBER FRAME.
COLOUR3 ———

TERRACE SLAB @ RL 20.89
RC BLOCK WALLS WITH SELECT CR
FINISH. COLOUR 3

90 x 49mm SHOTEDGE HWD TIMBER
BATTEN SCREEN. COLOUR 2

DETAILS ON SHEET 7

TIMBER FRAMED STAIRS WITH
SS WIRE BALUSTRADE

COLORBOND CUSTOM ORB
CLADDING TO MANUF. SPEC FIXED

 
 

90 x 19mm SHOTEDGE HWD

    

  

Property Line ( )

 

 

TO N3 NON-CYCLONIC RATING.
TIMBER BATTEN SCREEN.
ELEVATION B ~~ me
2
£
a
é COLORBOND CUSTOM ORB ROOF eo
$ 400 SHEETING TO MANUF. SPEC FIXED 1 —
| g or ore TON3 NON-CYCLONIC RATING. pot _—
COLOUR 1 _
ALUMINIUM FRAMED WINOOWS AND RENDERED FC SHEETING FIXED TO _— —

     
   
   

70mm TIMBER FRAME.
COLOUR 3

DOORS FIXED TO MANUFACTURER'S HWD RAFTERS AND BATTENS - SEALED AND

_ PITCH
JOINERY.

——— COLORBOND FASCIA

AND GUTTER.
COLOUR 1

UPPER FLOOR @ RL 23.84

CEILING
JOINERY.

100 X 100 HWD TIMBER
POSTS. COLOUR 3

LOWER FLOOR @ RL 20.94

BOUNDARY
FENCE

 

PITCH _
JOINERY

COLORBOND FASCIA
ANO GUTTER.
COLOUR 1

UPPER FLOOR @ RL 23.84
“CEILING

JOINERY

100 X 100 HWD TIMBER:
POSTS. COLOUR 3

BOUNDARY
FENCE

   

SPEC AND N3 RATING

 
     
 
 
  

 

 

gm ABOVE NGL

  
    
  
  
    

90 x 19mm SHOTEDGE HWD

i

TIMBER BATTEN SCREEN.

COLOUR 2

    

~ Southern Cross

 

ELEVATION D

Il

  

   
    
   
 
    

rend

PAINTED WHERE EXPOSED. COLOUR 3

GRANT STREET

 

COLORBSOND CUSTOM ORB ROOF
SHEETING TO MANUF. SPEC FIXED
TO N3 NON-CYCLONIC RATING.
COLOUR 1

 

 

 

— Oe

Ati

COLORBOND CUSTOM ORS
CLADDING TO MANUF. SPEC FIXED
TO N3 NON-CYCLONIC RATING.
COLOUR 1

Notes:
Des i g n & D r a ft i nN These drawings have been prepared for Building Permit application only. It is the Bullders/owners responsibility
to further interpret the design and drawings to detail the project for construction.
Commercial * industrial * residential building designers’ Builder shall verify all locations of services, dimensions and ‘evels prior to construction.
Suite/4 80 Sixth Ave Mar ochydore Setout dimensions on site shall be confirmed by builder before commencement of construction and ordering.
oochy;
Ph: 5479 5313 Fax: 5479 5314 association of Amend setout if necessary to comply with council by-laws and setback distances. STREET: Grant St
QBSA Lic 1110414 queenaland Inc. During construction the building shall be maintained in a stable condition and no part shall be overstressed.

Member

  
 

 

RENDERED FC SHEET FIXED TO
70mm TIMBER FRAME.
COLOUR 3

 

TERRACE SLAB @ RL 20.89
RC BLOCK WALLS WITH SELECT CR
FINISH. COLOUR 3

90 x 19mm SHOTEDGE HWD TIMBER
BATTEN SCREEN. COLOUR 2

 

 

HOODS. REFER
DETAILS ON SHEET 7

 

NOTES:

STAIRS TO COMPLY WITH BCA 3.9.1.3 AND 3.9.1.4
HANDRAILS AND BALUSTRADES TO

COMPLY WITH 3.9.2.3 (QLD)

(MIN 1000 HIGH AND 125 BETWEEN RAILS)

TIMBER FRAMED STAIRS WITH
SS WIRE BALUSTRADE

ROOF WATER TO BE DISCHARGED TO
ON-SITE WATER STORAGE TANKS
AS PER HYDRAULIC ENGINEERS

SCALE 1:100 DETAILS AND SPEC
N3
AMENDMENTS STRUCTURAL DESIGN BASED UPON
27.08.07 Raised carport slab RL NON-CYCLONIC N3 FOR WIND SPEEDS
& added 400mm setp in slab TO 41 mis.

Updated driveway profile
LINTELS SPECIFIED REFER ENGINEERS

19.09.07 Moved Unit 800mm towards rear REPORT. ALL WET AREAS TO COMPLY
boundary. WITH B.C.A. 3.8.1 LINE U/SIDE OF
Raise Unit 200mm and lower EXTERNAL COVERED AREAS WITH F/C
carport slab 250mm. SHEETING.
Updated driveway profile.
Add fixed s1azing panel above HATCHINGS AND FITTINGS ARE INDICATIVE

Changed truss roof on Upper level ONLY. REFER BUILDERS SPECIFICATION

to rafter & purlins with raked ceiling.
Changed wall between Bed 2 &
Terrace from timber frame to

RC block and changed door sizes.

TERMITE PROTECTION:
AS PER AUSTRALIAN STANDARDS AS3660. 1/2000

PROJECT INFORMATION ite: ELEVATIONS/COLOURS
2 JL

PROJECT TYPE: [ RESIDENTIAL |
CLIENT: Matthew & Joanne Exley

LoTMMeER [9

Noosa Heads

Date: 19/9/07

Scale: 1:100 At
(Revision: 2. | 2

 

 

Used in these records

About this file

File size
3.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_1993 - Op Works - landscaping, carparking, access, frontage works, stormwater, erosion & sediment control [As Published].pdf · 3.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.