COLOUR 3
Unit 2
4
poner RENDERED FC SHEETING FIXED TO
70mm TIMBER F
COLOUR 3
LOWER FLOOR@RL 20.96
100 X 100 HWD TIMBER POSTS.
COLOUR 3
LOWER FLOOR @ RL 20.94
TIMBER FRAMED STAIRS WITH __|
SS WIRE BALUSTRADE
SCALE 1:100
Unit
COLORBOND CUSTOM ORB ROOF
SHEETING TO MANUF. SPEC FIXED
TO N3 NON-CYCLONIC RATING.
COLOUR 1
i
a!
ELEVATIONA
RAME.
N3 RATING
1 Unit 2
RENDERED FC SHEETING FIXED
TO 70mm TIMBER FRAME.
COLOUR 3
FIRE RATED PARTITION WALL
TO MIN. FRL 60/60/60.
-— 1000mm GLAZE
BALUSTRADE
SELECT CR FINISH. COLOUR 3
SCALE 1:100
Sheet roof, gutters
& downpipes.
Custom Orb
cladding
Timber batten
screens
Rendered sheeting
, walls & exposed
timber
(truss tails, posts,
ELEVATION C
COLORBOND
"Windspray”
or equal colour
DULUX
; "Ferry"
or equal colour
OULUX
"Clay Bake”
or equai colour
beams & battens)
Schedule of External Colours
= Foe
ul bition a
“er
90x 19mm SHOTEDGE HWD TIMBER
BATTEN SCREEN. COLOUR 2
SUSPENDED RC SLAB TO
ENGINEERS DESIGN AND DETAIL
RC BLOCK WALLS WITH SELECT
GR FINISH. COLOUR 3
SOLAR HOT WATER SYSTEM AS
PER BUILDER'S CONTRACT.
POSITION TO BE VERIFIED
COLORBOND FASCIA AND
GUTTER. COLOUR 4
+—— ALUMINIUM FRAMED WiNDOWS
AND DOORS FIXED TO
MANUFACTURER'S SPEC AND
N3 RATING
COLORBOND CUSTOM ORB
CLADDING TO MANUF. SPEC FIXED
TO N3 NON-CYCLONIC RATING.
COLOUR 1
|
|
Line O
COLORBOND CUSTOM ORB ROOF
SHEETING TO MANUP. SPEC FIXED
TO N3 NON-CYCLONIC RATING.
COLOUR 1
Property
ef
ALUMINIUM FRAMED WINDOWS AND
DOORS FIXED TO MANUFACTURER'S
SPEC AND N3 RATING
RENDERED FC SHEETING FIXED TO
70mm TIMBER FRAME.
HWD RAFTERS AND BATTENS - SEALED AND COLOUR 3
PAINTED WHERE EXPOSED. COLOUR 3
GRANT STREET
ly
|
|
/
COLORBOND CUSTOM ORB ROOF
SHEETING TO MANUF. SPEC FIXED
TO N3 NON-CYCLONIC RATING.
RENOERED FC SHEET FIXED TO
70mm TIMBER FRAME.
COLOUR3 ———
TERRACE SLAB @ RL 20.89
RC BLOCK WALLS WITH SELECT CR
FINISH. COLOUR 3
90 x 49mm SHOTEDGE HWD TIMBER
BATTEN SCREEN. COLOUR 2
DETAILS ON SHEET 7
TIMBER FRAMED STAIRS WITH
SS WIRE BALUSTRADE
COLORBOND CUSTOM ORB
CLADDING TO MANUF. SPEC FIXED
90 x 19mm SHOTEDGE HWD
Property Line ( )
TO N3 NON-CYCLONIC RATING.
TIMBER BATTEN SCREEN.
ELEVATION B ~~ me
2
£
a
é COLORBOND CUSTOM ORB ROOF eo
$ 400 SHEETING TO MANUF. SPEC FIXED 1 —
| g or ore TON3 NON-CYCLONIC RATING. pot _—
COLOUR 1 _
ALUMINIUM FRAMED WINOOWS AND RENDERED FC SHEETING FIXED TO _— —
70mm TIMBER FRAME.
COLOUR 3
DOORS FIXED TO MANUFACTURER'S HWD RAFTERS AND BATTENS - SEALED AND
_ PITCH
JOINERY.
——— COLORBOND FASCIA
AND GUTTER.
COLOUR 1
UPPER FLOOR @ RL 23.84
CEILING
JOINERY.
100 X 100 HWD TIMBER
POSTS. COLOUR 3
LOWER FLOOR @ RL 20.94
BOUNDARY
FENCE
PITCH _
JOINERY
COLORBOND FASCIA
ANO GUTTER.
COLOUR 1
UPPER FLOOR @ RL 23.84
“CEILING
JOINERY
100 X 100 HWD TIMBER:
POSTS. COLOUR 3
BOUNDARY
FENCE
SPEC AND N3 RATING
gm ABOVE NGL
90 x 19mm SHOTEDGE HWD
i
TIMBER BATTEN SCREEN.
COLOUR 2
~ Southern Cross
ELEVATION D
Il
rend
PAINTED WHERE EXPOSED. COLOUR 3
GRANT STREET
COLORBSOND CUSTOM ORB ROOF
SHEETING TO MANUF. SPEC FIXED
TO N3 NON-CYCLONIC RATING.
COLOUR 1
— Oe
Ati
COLORBOND CUSTOM ORS
CLADDING TO MANUF. SPEC FIXED
TO N3 NON-CYCLONIC RATING.
COLOUR 1
Notes:
Des i g n & D r a ft i nN These drawings have been prepared for Building Permit application only. It is the Bullders/owners responsibility
to further interpret the design and drawings to detail the project for construction.
Commercial * industrial * residential building designers’ Builder shall verify all locations of services, dimensions and ‘evels prior to construction.
Suite/4 80 Sixth Ave Mar ochydore Setout dimensions on site shall be confirmed by builder before commencement of construction and ordering.
oochy;
Ph: 5479 5313 Fax: 5479 5314 association of Amend setout if necessary to comply with council by-laws and setback distances. STREET: Grant St
QBSA Lic 1110414 queenaland Inc. During construction the building shall be maintained in a stable condition and no part shall be overstressed.
Member
RENDERED FC SHEET FIXED TO
70mm TIMBER FRAME.
COLOUR 3
TERRACE SLAB @ RL 20.89
RC BLOCK WALLS WITH SELECT CR
FINISH. COLOUR 3
90 x 19mm SHOTEDGE HWD TIMBER
BATTEN SCREEN. COLOUR 2
HOODS. REFER
DETAILS ON SHEET 7
NOTES:
STAIRS TO COMPLY WITH BCA 3.9.1.3 AND 3.9.1.4
HANDRAILS AND BALUSTRADES TO
COMPLY WITH 3.9.2.3 (QLD)
(MIN 1000 HIGH AND 125 BETWEEN RAILS)
TIMBER FRAMED STAIRS WITH
SS WIRE BALUSTRADE
ROOF WATER TO BE DISCHARGED TO
ON-SITE WATER STORAGE TANKS
AS PER HYDRAULIC ENGINEERS
SCALE 1:100 DETAILS AND SPEC
N3
AMENDMENTS STRUCTURAL DESIGN BASED UPON
27.08.07 Raised carport slab RL NON-CYCLONIC N3 FOR WIND SPEEDS
& added 400mm setp in slab TO 41 mis.
Updated driveway profile
LINTELS SPECIFIED REFER ENGINEERS
19.09.07 Moved Unit 800mm towards rear REPORT. ALL WET AREAS TO COMPLY
boundary. WITH B.C.A. 3.8.1 LINE U/SIDE OF
Raise Unit 200mm and lower EXTERNAL COVERED AREAS WITH F/C
carport slab 250mm. SHEETING.
Updated driveway profile.
Add fixed s1azing panel above HATCHINGS AND FITTINGS ARE INDICATIVE
Changed truss roof on Upper level ONLY. REFER BUILDERS SPECIFICATION
to rafter & purlins with raked ceiling.
Changed wall between Bed 2 &
Terrace from timber frame to
RC block and changed door sizes.
TERMITE PROTECTION:
AS PER AUSTRALIAN STANDARDS AS3660. 1/2000
PROJECT INFORMATION ite: ELEVATIONS/COLOURS
2 JL
PROJECT TYPE: [ RESIDENTIAL |
CLIENT: Matthew & Joanne Exley
LoTMMeER [9
Noosa Heads
Date: 19/9/07
Scale: 1:100 At
(Revision: 2. | 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1993 - Op Works - landscaping, carparking, access, frontage works, stormwater, erosion & sediment control [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.