Original source · versioned page text
Appendix F- State Code 1
2. highly acoustically absorbent material
treatment for the total area of the soffit above
balconies or elevated outdoor play areas.
PO48 Development including: No acceptable outcome is provided. Not applicable.
1. indoor education areas and indoor play
areas in a childcare centre or educational
establishment; or
2. sleeping rooms in a childcare centre; or
3. patient care areas in a hospital located
above ground level, is designed and
constructed to achieve the maximum internal
acoustic level in reference table 3 (items 3.2-
3.4).
Air, light and vibration
PO49 Private open space, outdoor education AO49.1 Each dwelling or unit has access to a Not applicable.
areas and outdoor play areas are protected private open space which is shielded from a
from air quality impacts from a state-controlled state-controlled road by a building, solid gap-
road. free fence, or other solid gap-free structure.
OR
AO49.2 Each outdoor education area and
outdoor play area is shielded from a state-
controlled road by a building, solid gap-free
fence, or other solid gap-free structure.
PO50 Patient care areas within hospitals are AO50.1 Hospitals are designed and constructed Not applicable.
protected from vibration impacts from a state- to ensure vibration in the patient treatment area
controlled road or type 1 multi-modal corridor. does not exceed a vibration dose value of
0.1m/s1.75.
AND
AO50.2 Hospitals are designed and constructed
to ensure vibration in the ward of a patient care
State Development Assessment Provisions v3.0
State code 1: Development in a state-controlled road environment Page 15 of 18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.