Skip to the record
Beware of cheap imitations.

Original source · versioned page text

MCU14/0028 Appendix 3 chicken-meat-guidelines

of 56

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

A 2.4           Example calculation – S-factor formula

Example 1
Consider a proposed new 200 000 bird facility, consisting of five tunnel-ventilated sheds.

Step 1 – Location of sensitive land uses

The site is located 1200 m west of a small village. A number of farm houses are sited on properties
adjoining the proposed meat chicken farm site—the nearest is located 770 m to the north, another
900 m to the west and another 850 m to the south. The local government has been consulted
regarding the boundary of residential zonings for the village. The meat chicken farm site, village
boundary zone and neighbouring farm houses have been located using a GPS unit with +/- 5 m
accuracy.

The S1 factors are:
 50 for the boundary of the village zone—this is a non-rural zone.
 30 for the three neighbouring farm houses (sensitive land uses) to north, south and west.

Step 2 – Determination of surface roughness factor S2

The property is located in an area of flat to undulating topography, with mixed farming and forestry
land the dominant land uses. The forestry land has not been logged for many years, with logging or
clearing unlikely to occur in the near future. The land between the proposed meat chicken farm and
the farmhouse to the north is undulating with an established 100 m thick continuous timber belt
along the northern boundary within the property. Forestry land extends from the eastern boundary
of the property to the boundary of the village zone. The land between the proposed meat chicken
farm site and the farmhouses to the south and west is flat to undulating with scattered clumps of
trees and a few trees along fences.

   The surface roughness used for the village would be heavy timber (S2S = 0.77) due to the well-
    established continuous stand of forestry and the fact that it is unlikely to be cleared.
   The surface roughness used for the farmhouse to the north would be level wooded country
    (S2S = 0.85) due to the undulating nature of the terrain plus the continuous belt of established
    timber within the property in those directions.
   The surface roughness used for the farmhouses to the south and west of the proposed
    development would be limited ground cover/short grass (S2S = 1.0) due to the flat to undulating
    nature of the terrain and the lack of a continuous, thick tree cover.

Step 3 – Determination of terrain weighting factor S3

The terrain of the area is flat to undulating, thus the terrain weighting factor S3 = 1.

Step 4 – Calculation of required separation distances

The required separation distance for the farmhouse to the north:
 Check S2*S3 – > 0.68
 D = (200000/1000)0.63 * 30 * 0.85 *1.0 = 718 m

This is less than the actual distance of 770 m.

   The required separation distance for the farmhouses to the west and south:
   Check S2*S3 - > 0.68
   D = (200000/1000)0.63 * 30 * 1.0 *1.0 = 845 m


Queensland Guidelines Meat Chicken Farms                                                     52
Log in to download the original file

MCU14_0028 Appendix 3 chicken-meat-guidelines.pdf · 360 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.