Original source · versioned page text
Revised Architecturals ISSUE 5 - received 10.03.21
Original PDF page 5, section 2. The text section number identifies this passage in the reader.
1,200
70
960
450
220
820
PORTICO
D.P
18-09DH 18-09DHD.P tiled 06-24SW 06-24SW - 2 18-09DH
70
70
70
70
70
D.P D.P D.P
70
220
1,170
MH
lintel
lintel
1,970
1,520
ed
1,520
rak iling
2400 x 1500
AREAS: SQ METRES:
LIVING 241.9 ce 350 x 470 brick piers 4
D.P
GARAGE 44.0 3 1
X
220 6,000 220
350
PORCH 6.0 2
ALFRESCO 35.90
21-48 PANEL LIFT
DOUBLE GARAGE
6,960
FLOOR PLAN
DOOR - AUTO
meter box
gable roof
plain concrete
6,440
6,000
6,000
6,240
6,240
6,240
6,240
6,240
TOTAL = 327.8 m2 SCALE 1:100
4,720
4,720
220 9,610 70 1,870 70 1,000 70 1,970 70 1,000 70 5,150 70 950 70 3,580 220 1,670
220 21,970 70 3,580 220
530 600 70 70
70 5,000 90 2,280 70 3,200 70 3,400 70 70 3,400 70 70 830 950 900 70 2,610 220
530 600 70
2,300 470 70 3,400 70 70 3,400 70 70 830 950 70 3,580 220 1,670
HC
D.P
5,140 14,530
18-09DH 18-09DH
220
220
220
1,350 4,670 3,240 11,760 6,440 270
27,730
NOTES PLAN LEGEND CLIENT:
PLEASE READ CAREFULLY
10. Protection against subterranean termites shall be in accordance with AS
THIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO IN THE
G. LEWIS & S. PASSEY
1. Written dimensions take precedence over scale. 3660-Pt 1 2001. Provided treatment: Visual Barrier System to perimeter with afl = above floor level ref = refrigerator prov. CONTRACT & SPECIFICATIONS AND I UNDERSTAND CHANGES
2. Builder to verify all dimensions and levels prior to commencement of construction. approved collars/barriers at slab penetrations. hd = head at 2100 afl. mw = microwave prov. HEREAFTER MAY NOT BE POSSIBLE. THESE PLANS SUPERCEDE ALL
3. All internal dimensions stated are frame size - excluding linings. 11. HWS unit (constant flow) with 5 star energy efficiency rating to comply fw = floor waste dw = dishwasher prov. OTHER PREVIOUS PLANS OR SKETCHES.
Lot 4, 297 Lawnville Road
4. This building has been designed in accordance with AS 1684.2 - 2006 (Residential with "Sustainable Buildings" QDC pt 29, AS/NZs 6400:2005. = smoke detector pty = pantry
timber framed construction). 12. Rainwater tanks, lighting and plumbing fixtures & fittings to comply with QDC vb = vanity basin wm = washing machine prov. BLACK MOUNTAIN
Stroud Homes Pty Ltd 5. Supplier may substitute lintels for those of equal strength to span ratio. PART 29 & 25, 'Sustainable Buildings' QDC pt 29 & 25 AS/Nzs 300.1.2003 obs = obscure glazing ghw = gas hot water unit
ABN: 49 107 897 736 QBSA Lic No: 1083367 6. All structural sizes to be read in-conjunction with structural engineers drawings & AS/NZS 6400:2005. mb = meter box tr = towel rail MODEL: JOB
OWNER/S No. 20L297LA
details. 13. Lift off hinges to all WC doors to comply with Australian Standards. dp = downpipe trh = toilet roll holder Montego 329 Skillion
107 Sugar Road Telephone: Email: 7. Articulation joints to complay with 3.3.1.8 BCA Vol 2. 14. Stair construction to comply with Pt 3.9.1 and balustrades to comply with pt ohc = overhead cupboard HC = garden tap
WITNESS DATE
Maroochydore 07 5444 2521 Daniel.chapman 8. Mechanical Ventilation to comply with 3.8.5 Bca Vol 2. 3.9.2 BCA Vol 2. ISSUE/DATE: SHEET
QLD Mobile: @stroudhomes. No.
9. Smoke alarms to comply with 3.7.2 BCA Vol 2 (wired-in) 15. DCP & flashings to comply with Pt 3.3.4 BCA Vol 2
4558 0402 864 305 com.au C 2016 REPRODUCTION IN PART OR WHOLE IS STRICTLY FORBIDDEN
ISSUE 5 : 8/03/2021 5 OF 12
GSPublisherVersion 0.0.100.100