Revised Architecturals ISSUE 5 - received 10.03.21

of 19

Page text shows just the words. Original shows the document exactly as it was published.

Original PDF page 9, section 1. The text section number identifies this passage in the reader.

                                                                                                                                                                            TRUSSES AT 900mm CENTRES
                                                                                                                                                                        TO MANUFACTURER'S SPECIFICATIONS                                                                                                       SHEET METAL ROOF
                                                                                                                                            450                                                                                                                                                            AT 12.5 DEG.PITCH FIXED TO
                                                                                                                                                                                                                                                                                                        MANUFACTURER'S SPECIFICATIONS

                                                                                                                                    OVERHANGS
                                                                                                                                 FROM FACE OF WALL


                                                                                       from slab to underside of truss

                                                                                                                                                                                                                                                                                                                                                     4.5mm FC.SHEET TO
                                                                                                                         window height                                                                                                                                                                                                                  TIMBER FRAMING
                                                                                                    2,740




                                                                                                                                                                           BATH                                                                                                                 BED 3
                                                                                                                             2,100




                                                                                                                                   BRICK VENEER CLADDING                                                                  SECTION XX                                                                            CONCRETE FOOTINGS & SLAB
                                                                                                                                   WEEPHOLES EVERY THIRD                                                                  SCALE 1:50                                                                           TO ENGINEERS SPECIFICATION
                                                                                                                                   PERPEND AT FLASHING COURSE

                                                                                                                                                                                                                                                             TERMITE PROTECTION IS A VISUAL BARRIER SYSTEM WITH
                                                                                                                                         N3 WIND DESIGN RATING                                                                                                      APPROVED COLLARS AT PENETRATIONS
                                                                                                                                                                                                                                                                     IN ACCORDANCE WITH AS.3600.1 - 2000




                                                                   NOTES                                                                                                                                                                               PLAN LEGEND                                                                                                                                     CLIENT:
                                                                                                                                                                                                                                                                                                                                PLEASE READ CAREFULLY
                                                                                                                                                            10. Protection against subterranean termites shall be in accordance with AS
                                                                                                                                                                                                                                                                                                                     THIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO IN THE
                                                                                                                                                                                                                                                                                                                                                                                               G. LEWIS & S. PASSEY
                                                                   1. Written dimensions take precedence over scale.                                            3660-Pt 1 2001. Provided treatment: Visual Barrier System to perimeter with            afl = above floor level    ref = refrigerator prov.             CONTRACT & SPECIFICATIONS AND I UNDERSTAND CHANGES
                                                                   2. Builder to verify all dimensions and levels prior to commencement of construction.        approved collars/barriers at slab penetrations.                                        hd = head at 2100 afl.     mw = microwave prov.               HEREAFTER MAY NOT BE POSSIBLE. THESE PLANS SUPERCEDE ALL
                                                                   3. All internal dimensions stated are frame size - excluding linings.                    11. HWS unit (constant flow) with 5 star energy efficiency rating to comply                fw = floor waste           dw = dishwasher prov.                         OTHER PREVIOUS PLANS OR SKETCHES.
                                                                                                                                                                                                                                                                                                                                                                                          Lot 4, 297 Lawnville Road
                                                                   4. This building has been designed in accordance with AS 1684.2 - 2006 (Residential           with "Sustainable Buildings" QDC pt 29, AS/NZs 6400:2005.                                  = smoke detector      pty = pantry
                                                                      timber framed construction).                                                          12. Rainwater tanks, lighting and plumbing fixtures & fittings to comply with QDC          vb = vanity basin          wm = washing machine prov.                                                                                  BLACK MOUNTAIN
                    Stroud Homes Pty Ltd                           5. Supplier may substitute lintels for those of equal strength to span ratio.                PART 29 & 25, 'Sustainable Buildings' QDC pt 29 & 25 AS/Nzs 300.1.2003                 obs = obscure glazing      ghw = gas hot water unit
                    ABN: 49 107 897 736 QBSA Lic No: 1083367       6. All structural sizes to be read in-conjunction with structural engineers drawings &       AS/NZS 6400:2005.                                                                      mb = meter box             tr = towel rail                                                                                MODEL:                          JOB
                                                                                                                                                                                                                                                                                                                   OWNER/S                                                                                       No.     20L297LA
                                                                      details.                                                                              13. Lift off hinges to all WC doors to comply with Australian Standards.                   dp = downpipe              trh = toilet roll holder                                                                             Montego 329 Skillion
                    107 Sugar Road   Telephone:   Email:           7. Articulation joints to complay with 3.3.1.8 BCA Vol 2.                                14. Stair construction to comply with Pt 3.9.1 and balustrades to comply with pt           ohc = overhead cupboard    HC = garden tap
                                                                                                                                                                                                                                                                                                                   WITNESS                                 DATE
                    Maroochydore     07 5444 2521 Daniel.chapman   8. Mechanical Ventilation to comply with 3.8.5 Bca Vol 2.                                    3.9.2 BCA Vol 2.                                                                                                                                                                                                 ISSUE/DATE:                     SHEET
                    QLD              Mobile:      @stroudhomes.                                                                                                                                                                                                                                                                                                                                                   No.
                                                                   9. Smoke alarms to comply with 3.7.2 BCA Vol 2 (wired-in)                                15. DCP & flashings to comply with Pt 3.3.4 BCA Vol 2
                    4558             0402 864 305 com.au                                                                                                                                                                                        C   2016 REPRODUCTION IN PART OR WHOLE IS STRICTLY FORBIDDEN
                                                                                                                                                                                                                                                                                                                                                                                 ISSUE 5 : 8/03/2021                      9 OF 12
GSPublisherVersion 0.0.100.100
Log in to download the original file

Revised Architecturals ISSUE 5 - received 10.03.21.pdf · 2.0 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.