Original source · versioned page text
Revised Architecturals ISSUE 5 - received 10.03.21
Original PDF page 11, section 1. The text section number identifies this passage in the reader.
28,180
450 11,990 9,030 5,040 1,670
1,690 9,700 600
50
350
2,340
2,340
50 350 4,275 350 4,275 350 50
1,940
50mm STEPDOWN
TO ALFRESCO
1,360
1,470
2,910
1,550
1,906
1,906
2,213
670
6,470
SINK BATH
4,720
1,850
WASTE WASTE 4,593 3,670
4,120 3,505
565
3,220
2,440
3,350
VANITY
WASTE FW
3,725
SINK FLOOR DOES NOT FALL TO WASTE
2,350
WASTE
4,010
WC
1,000
5,550
WASTE FW
1,300
SHR
VANITY
6,250
FLOOR DOES NOT FALL TO WASTE
3,370
VANITY
VANITY WASTE WASTE
WASTE
1,794
6,970
7,020
1,000
WC
19,550
19,550
10,990 WASTE 1,670
10,740 13,380 SHR
6,350 10,120 12,010 13,080
12,630 900
4,580
1,755 2,045
31,
3,470
706
9,660
1,400
TUB 1,290
WASTE
BOLD LINE REPRESENTS THE
EXTERIOR PERIMETER OF THE DWELLING
1,520 450
740
50mm STEPDOWN
1,170
TO PORCH
5,060 OA
350
NOTE:
GARAGE DOOR REBATE
NO STEPDOWN TO GARAGE
80
ROLL EGDE TIMBER PLUMBER/DRAINER TO VERIFY ALL DIMENSIONS
FRAME
PRIOR TO POSITIONING ALL UNDERSLAB POINTS.
6,440
DOOR JAMB DOOR JAMB MEASURMENTS MAY VARY.
6,240
5,060
FLOOR WASTE FIXTURES TO BE POSITIONED
BRICK 4,860
AT THE TIME OF CONSTRUCTION.
4,720
SLAB PLAN DETAIL NOT TO SCALE
TERMITE PROTECTION:
SCALE 1:100 TERMITE PROTECTION IS A VISUAL BARRIER SYSTEM
WITH APPROVED COLLARS AT PENETRATIONS IN
470 2,300 470 ACCORDANCE WITH AS.3600.1 - 2000
4,670 3,240 11,760
440
450 1,350 5,140 2,300 12,230 6,440 270
28,180
NOTES PLAN LEGEND CLIENT:
PLEASE READ CAREFULLY
10. Protection against subterranean termites shall be in accordance with AS
THIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO IN THE
G. LEWIS & S. PASSEY
1. Written dimensions take precedence over scale. 3660-Pt 1 2001. Provided treatment: Visual Barrier System to perimeter with afl = above floor level ref = refrigerator prov. CONTRACT & SPECIFICATIONS AND I UNDERSTAND CHANGES
2. Builder to verify all dimensions and levels prior to commencement of construction. approved collars/barriers at slab penetrations. hd = head at 2100 afl. mw = microwave prov. HEREAFTER MAY NOT BE POSSIBLE. THESE PLANS SUPERCEDE ALL
3. All internal dimensions stated are frame size - excluding linings. 11. HWS unit (constant flow) with 5 star energy efficiency rating to comply fw = floor waste dw = dishwasher prov. OTHER PREVIOUS PLANS OR SKETCHES.
Lot 4, 297 Lawnville Road
4. This building has been designed in accordance with AS 1684.2 - 2006 (Residential with "Sustainable Buildings" QDC pt 29, AS/NZs 6400:2005. = smoke detector pty = pantry
timber framed construction). 12. Rainwater tanks, lighting and plumbing fixtures & fittings to comply with QDC vb = vanity basin wm = washing machine prov. BLACK MOUNTAIN
Stroud Homes Pty Ltd 5. Supplier may substitute lintels for those of equal strength to span ratio. PART 29 & 25, 'Sustainable Buildings' QDC pt 29 & 25 AS/Nzs 300.1.2003 obs = obscure glazing ghw = gas hot water unit
ABN: 49 107 897 736 QBSA Lic No: 1083367 6. All structural sizes to be read in-conjunction with structural engineers drawings & AS/NZS 6400:2005. mb = meter box tr = towel rail MODEL: JOB
OWNER/S No. 20L297LA
details. 13. Lift off hinges to all WC doors to comply with Australian Standards. dp = downpipe trh = toilet roll holder Montego 329 Skillion
107 Sugar Road Telephone: Email: 7. Articulation joints to complay with 3.3.1.8 BCA Vol 2. 14. Stair construction to comply with Pt 3.9.1 and balustrades to comply with pt ohc = overhead cupboard HC = garden tap
WITNESS DATE
Maroochydore 07 5444 2521 Daniel.chapman 8. Mechanical Ventilation to comply with 3.8.5 Bca Vol 2. 3.9.2 BCA Vol 2. ISSUE/DATE: SHEET
QLD Mobile: @stroudhomes. No.
9. Smoke alarms to comply with 3.7.2 BCA Vol 2 (wired-in) 15. DCP & flashings to comply with Pt 3.3.4 BCA Vol 2
4558 0402 864 305 com.au C 2016 REPRODUCTION IN PART OR WHOLE IS STRICTLY FORBIDDEN
ISSUE 5 : 8/03/2021 11 OF 12
GSPublisherVersion 0.0.100.100