App A - Acoustic Report - Minor Change - 12.08.2025

of 173

Page text read automatically using OCR, there may be inaccuracies

Sunshine Beach Surf Club                                                                             Reference: #1721d1-C
Belmore Terrace, Sunshine Beach QLD 4567                                                           Date: 12 November 2024
Entertainment Noise Assessment

4 Results and Discussion
 4.1 Summary of findings
 No major acoustical issues were identified during testing.                                          G51 Check Item 47 ☐


 Compliance should be monitored at the CEMLs where possible. The
 purpose of this is to provide flexibility to the licensee with regard to the
 specific configuration of the venue, provided that the limits at the CEMLs
 are not exceeded. This approach also aims to minimise cumbersome
 noise conditions, such as “XX dBA when X doors and X windows are
 closed, etc.”.



 4.2 Recommended close external noise limits
 Presented below are the summarised noise limits at the CEMLs, based upon the calculations
 provided in Appendix B – Calculation Summaries. The limits presented indicate the calculated
 level limit for the venue operating configuration as described in Section 3.7. Measurements
 should be made at the CEML in either dBA (before 10:00PM) or dBC (after 10:00PM) using
 ‘Fast’ time weighting.


                                 Table 6. Calculated noise limits at the CEMLs
 Close external monitoring    Limiting representative       Maximum noise limit at CEML
 location (CEML) [3]          affected premises
                                                            Before 6:00PM,         Before 10:00PM,       After 10:00PM,
                                                            dBA [1]                dBA [1]               dBC [2]
 L2                           RAP.1                         61                     56                    58
 L3                           RAP.2                         61                     56                    55
   L6                          RAP.4                          55                     56                   63
G51 Check Item 48 ☐
[1]
    Measured in dBA using a ‘Fast’ Time Weighting.
[2]
    Measured in dBC or dBZ using a ‘Fast’ Time Weighting.
[3]
    CEML locations are marked in Figure 8 and photos provided in Appendix D – Detailed Measurement Locations.



 4.3 Recommended specific licensed premises area noise limits
 Presented below are the summarised noise limits at the SLPAs, based upon the calculations
 provided in Appendix B – Calculation Summaries. The limits presented indicate the calculated
 level limit for the venue operating configuration as described in Section 3.7. Measurements
 should be made at the SLPA in either dBA (before 10:00PM) or dBC (after 10:00PM) using
 ‘Fast’ time weighting.




Live It Acoustics | Controlled Document v1.0                                                                         Page 28

Log in to download the original (App A - Acoustic Report - Minor Change - 12.08.2025.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.