         5.2.2 Maximum Values of Light Technical Parameters
Excerpt from Standard Table 3.2 Maximum Values of Light Technical Parameters
                  Vertical illuminance levels
                               (Ev)                          Threshold increment (TI)            Sky glow
                                Lx
 Zones
                                                                              Default
                                                                                                  Upward
               Non-curfew               Curfew                %            adaptation level
                                                                                                 light ratio
                                                                               (Lad)
   A0          See Note 1                  0                   N/A              N/A                 0
   A1                2                    0.1                  N/A              N/A                 0
   A2                5                     1                   20%               0.2               0.01
   A3               10                     2                   20%                1                0.02
   A4               25                     5                   20%                5                0.03
   TV         See Table 3.4               N/A                  20%               10                0.08
   V                N/A                    4                 Note 2            Note 2             Note 2
   R1               N/A                    1                   20%               0.1              Note 3
   R2               N/A                    2                   20%               0.1              Note 3
   R3               N/A                    4                   20%               0.1              Note 3
   RX               N/A                    4                   20%                5               Note 4
NOTES:
1 For A0, Ev shall be as close to zero as practicable without impacting safety considerations.
2 Refer to AS/NZS 1158.1.1.
3 Refer to AS/NZS 1158.3.1.
3 Refer to AS/NZS 1158.4.
4 N/A means ‘Not Applicable’.
5 For an internally illuminated sign in an A2 zone, Lad =< 0.25 cd/m2.

Excerpt from Standard Section 3.3.5.7 (c)

Internally illuminated surfaces shall have an ULR of not greater than 50% and the
design shall include facilities to mitigate upward waste light.

Excerpt from Standard Table 3.3 Maximum Luminous Intensities Per Luminaire
 Zone                                                Luminous intensity (I), cd
                           Non-curfew L1              Non-curfew L2              Curfew
 A0                        See Note                   See Note                   0
 A1                        2 500                      5 000                      500
 A2                        7 500                      12 500                     1 000
 A3                        12 500                     25 000                     2 500
                                                                                                               rubidium
 A4                        25 000                     50 000                     2 500
 TV                        100 000                    150 000                    0
NOTE: For A0, I shall be as close to zero as practicable without impacting safety
considerations.


Excerpt from Standard Table 3.5 Maximum Average Luminance of Surfaces (cd/m²)

   Application                                      Environmental zones
   conditions          A0                   A1              A2                 A3                 A4
  See Clause
                       0.1                  0.1              150               250               350
     3.3.5.4
Excerpt from Standard Section 3.3.5.4
                                                                                                               light




Where the graphical content or colours can change, the dwell time of the image shall be 10 seconds or
more, and the average luminance shall change by less than 30% on the change of the image.


7|Page                                  www.rblight.com.au
Log in to download the original file

Attachment 9- Lighting Impact Assessment.pdf · 30.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.