Council archive · source document
Approved Plans MCU16/0049 & OPW16/0109
Plans and drawings: the text below has words only, no drawings.
LINETYPE LEGEND -
BANK BOTTOM NOOSA COUNCIL
BANK TOP
APPROVED PLAN
BATTER
CROWN E MCU16/0049 & OPW16/0109
l
GUTTER
GRAVEL M Design
BITUMEN
KERB a 6 DEC 2016 PO Box 290
Peregian Beach QLD 4573
CONCRETE BSA No. 1066058
ELECTRICAL
WATER
IL
By 48
Un . 7 8
0
.3 .16
n Contact: Michael Broeren
ity 49 49 t. 07 5471 2721
DAM/POOL
SEWER
DRAINAGE
wa
te
r
d t. 0422 969 645
w. www.m-designs.com.au
50
TREELINE
GARDEN
TELSTRA .3
MH
8 LL 49.57 6
.6 .51 68
a
BUILDING 50 49 49 49.
PAVING 5
.5
RETAINING WALL
50
WALL
GUARDRAIL
H
50
4
.4 49
.8
5
.9
2
49 .80
S
6 5
t
FENCE
.7 499.9 © COPYRIGHT 2016 - M DESIGN
BDY
IO 50 4 4 50 THE IDEAS AND CONCEPTS
MAJOR CONTOUR .2 8 BM: Nail in Kerb CONTAINED WITHIN THIS DOCUMENT
MINOR CONTOUR
LL 50.89 50
50
.0 RL: 50.08
r AND THE DOCUMENT ITSELF REMAIN
THE INTELLECTUAL PROPERTY OF M
50
.9
3 e DESIGN AND MAY NOT BE COPIED
OR REPRODUCED IN PART OR IN
PROPOSED VISITOR PARKING .7
5 Ke WHOLE WITHOUT EXPRESSED
e
STORMWATER GRATE rb WRITTEN PERMISSION FROM
50 & MICHAEL BROEREN OF M DESIGN.
SW STORMWATER MANHOLE 1 G
REFER TO FLOOR PLAN .5 ut
APPROX SIZE & LOCATION 51 .93 te
t
158
26.07.16
05.09.16
07.10.16
r
159
DATE
S SEWER MANHOLE
50 7
51 1351.1
15 3°0
EJ ELECTRICITY JUNCTION 6 1 4
BOX RP48112 .8 .2 .4
TELSTRA PIT 51 4 PP 51 50 59
.8 569m² .0 0'0 .
RELOCATED LDR'Y CBD, AMENDED GFA,
WM WATER METER 51 94 0 50
H HYDRANT " 8
TELSTRA
51
.3
STOP VALVE .9
5 1 51 .6
3
DESCRIPTION
51 .5 7 51
51
AMENDED SITE COVERAGE
POWER POLE .7
RE-ISSUE FOR APPROVAL
LIGHT POLE
51
BENCH MARK 0
.0 5
52 1.7
CLIENT REVIEW
5
52 PROPOSED SINGLE GARAGES
2 REFER TO FLOOR PLAN
.2
52 APPROX SIZE & LOCATION
9 4
.2 .1
52 52 2
REV
.8
G
52
A
0
I
9 .9
.2
52 51
0 NS
6 .2
.1 52
PROPOSED 2 PROPOSED VISITOR PARKING
38 Elanda Street, Sunshine Beach QLD
5 0
.0
INGROUND POOL 52 REFER TO FLOOR PLAN
24 "
.7 '20
APPROX SIZE & LOCATION
REFER TO FLOOR PLAN
1
37 °01
APPROX SIZE & LOCATION .5
52
UNIT 2 1
43
.1
0 53
.2
8 52
.6
51
0"
PROPOSED TWO
3° 7
22 .72
'3
PROPOSED DUPLEX
UNIT 1
01
8
STOREY RESIDENCES
37
.7
51
REFER TO FLOOR PLAN
3 APPROX SIZE & LOCATION
CP .5
9 .5
Geoff Connan
51 52 4
BUP9902 .8
52
Project Address:
51
.3
6
9
CP
.9 BUP5193
0 51
.5
51
1
For:
31 5.0 PROPOSED PRIVATE
03 92
.3 °0
NOT FOR CONSTRUCTION
51 0' 5
OUTDOOR SPACE sheet title:
40 51
.8 APPROX SIZE & LOCATION
" SITE PLAN
north 52
5
135 51
.3
.3
4 job no: drawn by:
RP48112 52 1626 LBW
SITE PLAN
6
1 : 200 .7 date: 28/11/2016
51
10:31:56 AM
0 2 4 6 8m
1:200 scale (A3): drawing no:
1 : 200 1.1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 9 pages
Page 2
8000 1
7980
5.1 4.1
6000 2000 1980 6000
SETBACK SETBACK
2
600
223° 00' 58" 37.73 m
l l
co co
SETBACK
BIN
SETBACK
1500
ENCLOSURE
2000
ROOF OVER
2000
CLOTHES LINE
VISITOR l
DP co SCR
e t
PARKING SCR
DP2 t
DP2 ps GRASS
l l
co co
BUILDING OVER
AWNING ABOVE DP
DRIVEWAY ENTRY BUILDING OVER DP
ROCK FACE WALL
r e
52000 MEALS
l
UNIT 1 PAVERS 1 4.2
co l UP
co
DECK OVER
TV
t
DW
2
GARAGE WM
LIVING 2
TELESCOPIC SLIDING GATES
DRY STORE
KITCHEN
S
5.1 LT 5.1
HP
STAIR WC3
L'DRY FR
HB WATER FEATURE
FEATURE STONE GRAVEL
HB
313° 00' 08" 15.09 m
FR
L'DRY STAIR
HP
WC3
VERANDAH ROOF OVER
a
LT
4.1 1 DRY KITCHEN
GARAGE WM
STORE LIVING
DECK OVER
SK DW
PAVERS PLUNGE
d
TV POOL
l
l co UP
co
132° 59' 28" 15.09 m
UNIT 2
n
MEALS BAL 2
DRIVEWAY
l l
co co
E l a
AWNING ABOVE DP
ENTRY DP2 t
DP
TIMBER PALING FENCE
DP2
BUILDING OVER
ps GRASS
VISITOR SCR SCR
l
SETBACK
PARKING DP co
2000
SETBACK
2000
CLOTHES LINE
1500
ROOF OVER
BIN
l ENCLOSURE
co l
co
43° 00' 48" 37.72 m
600
2 PLOT RATIO SITE COVERAGE
1
= 45.4% GFA LEVEL 1 = 193.227m²
4.2 = 34%
rth
5.1
LEVEL 1 2 x 62.51m²
LEVEL 2 = 203.434m²
no
= 125.02m² = 35.7%
-
NOOSA COUNCIL LEVEL 2 2 x 66.85m²
= 133.70m² LANDSCAPE = 239.8m²
APPROVED PLAN
LEVEL 1 TOTAL 2 x 130.24m² 60% SOFTSCAPE
MCU16/0049 & OPW16/0109 = 258.72m²
1 : 100 6 DEC 2016 0 1 2 3 4m
1:100
ISSUE: NOT FOR CONSTRUCTION ABBREVIATION LEGEND sheet title:
SK SINK
M Design
© COPYRIGHT 2016 - M DESIGN Proposed Duplex: REV DESCRIPTION DATE LT LAUNDRY TUB HP HOT PLATE FLOOR PLAN -
THE IDEAS AND CONCEPTS
PO Box 290 A CLIENT REVIEW 26.07.16 WM WASHING MACHINE, BY OTHERS FR REFRIGERATOR
Peregian Beach QLD 4573
CONTAINED WITHIN THIS For:
B CLIENT REVIEW 12.08.16 DRY CLOTHES DRYER, BY OTHERS DW DISHWASHER
LEVEL 1
DOCUMENT AND THE DOCUMENT
ITSELF REMAIN THE INTELLECTUAL Geoff Connan C CLIENT REVIEW 24.08.16 LIN LINEN pst POST, TO STRUCT ENGINEERS DETAILS job no: drawn by:
PROPERTY OF M DESIGN AND MAY D FOR APPROVAL 25.08.16 SHR SHOWER col COLUMN, TO STRUCT ENGINEERS DETAILS
E RE-ISSUE FOR APPROVAL 30.08.16 1626 LBW
NOT BE COPIED OR REPRODUCED VB VANITY BASIN DP 100mm DOWNPIPE
IN PART OR IN WHOLE WITHOUT Project Address: F CHANGED WINDOWS 31.08.16
HB HAND BASIN DP2 150mm DOWNPIPE date:
G RE-ISSUE FOR APPROVAL 05.09.16
BSA No. 1066058 EXPRESSED WRITTEN PERMISSION MR MIRROR GU GUTTER, TO HYD ENGINEERS DETAILS 14.07.16
Contact: Michael Broeren
FROM MICHAEL BROEREN OF 38 Elanda Street, H AMENDED GFA & SITE COVERAGE, REMOVED
LAUNDRY, RELOCATED WC3
30.09.16
TR TOWEL RAIL BAL 1 BALUSTRADE, TYPE TBC
M DESIGN. scale (A3): drawing no:
t. 07 5471 2721 Sunshine Beach QLD I RELOCATED LDR'Y CBD, AMENDED GFA, 07.10.16 WC WATER CLOSET BAL 2 FRAMELESS GLASS BALUSTRADE
t. 0422 969 645 AMENDED SITE COVERAGE SG SHOWER GRATE SCR VERTICAL TIMBER SCREEN 1 : 100 2.1
Page 3
1
5.1
6500 4.1 7980
6000 500 1980 6000
2
SETBACK SETBACK
SETBACK
DP
2000
450
LINE OF WALL BELOW
LINE OF ROOF OVER
KLIP-LOK @1°
t
ps BAL 1 LINE OF ROOF OVER t
DP2
LINE OF ROOF OVER DP2 ps
WC 1 VO
ID AWNING DP
DP ROBE ROBE
BAL 2
WALKWAY
DECK 1 4.2
BAL 2
BAL 2
t ENS 1 VB VB
ENS 2
ps SCR
ROBE
2 BED 1 TR VO WC 2
ID TR BED 2
5.1 SG 5.1
SG
SHR STAIR SHR KLIP-LOK @1°
SHR SHR
STAIR
SG SG
VO
t ID BED 2
ROBE
4.1 1 ps BED 1 TR WC TR
SCR
ENS 2
LINE OF ROOF OVER
ENS 1 VB VB
BAL 2
DECK BAL 2
WALKWAY
BAL 2
ROBE ROBE
BAL 1
VO DP
ID AWNING DP
WC 1 t
LINE OF ROOF OVER DP2 ps
t LINE OF ROOF OVER
ps
DP2
KLIP-LOK @1°
LINE OF ROOF OVER
SETBACK
450
LINE OF WALL BELOW
2000
DP
2
PLOT RATIO SITE COVERAGE
= 45.4% GFA LEVEL 1 = 193.227m²
= 34%
rth
4.2 LEVEL 1 2 x 62.51m²
LEVEL 2 = 203.434m²
o
1
n
5.1
= 125.02m² = 35.7%
-
LEVEL 2 2 x 66.85m²
NOOSA COUNCIL
= 133.70m² LANDSCAPE = 239.8m²
APPROVED PLAN TOTAL 2 x 130.24m² 60% SOFTSCAPE
LEVEL 2 MCU16/0049 & OPW16/0109 = 258.72m²
1 : 100 6 DEC 2016 0 1 2 3 4m
1:100
ISSUE: NOT FOR CONSTRUCTION ABBREVIATION LEGEND sheet title:
SK SINK
M Design
© COPYRIGHT 2016 - M DESIGN Proposed Duplex: REV DESCRIPTION DATE LT LAUNDRY TUB HP HOT PLATE FLOOR PLAN -
THE IDEAS AND CONCEPTS
PO Box 290 A CLIENT REVIEW 26.07.16 WM WASHING MACHINE, BY OTHERS FR REFRIGERATOR
Peregian Beach QLD 4573
CONTAINED WITHIN THIS For:
B CLIENT REVIEW 12.08.16 DRY CLOTHES DRYER, BY OTHERS DW DISHWASHER
LEVEL 2
DOCUMENT AND THE DOCUMENT
ITSELF REMAIN THE INTELLECTUAL Geoff Connan C CLIENT REVIEW 24.08.16 LIN LINEN pst POST, TO STRUCT ENGINEERS DETAILS job no: drawn by:
PROPERTY OF M DESIGN AND MAY D FOR APPROVAL 25.08.16 SHR SHOWER col COLUMN, TO STRUCT ENGINEERS DETAILS
E RE-ISSUE FOR APPROVAL 30.08.16 1626 LBW
NOT BE COPIED OR REPRODUCED VB VANITY BASIN DP 100mm DOWNPIPE
IN PART OR IN WHOLE WITHOUT Project Address: F CHANGED WINDOWS 31.08.16
HB HAND BASIN DP2 150mm DOWNPIPE date:
G RE-ISSUE FOR APPROVAL 05.09.16
BSA No. 1066058 EXPRESSED WRITTEN PERMISSION MR MIRROR GU GUTTER, TO HYD ENGINEERS DETAILS 14.07.16
Contact: Michael Broeren
FROM MICHAEL BROEREN OF 38 Elanda Street, H AMENDED GFA & SITE COVERAGE, REMOVED
LAUNDRY, RELOCATED WC3
30.09.16
TR TOWEL RAIL BAL 1 BALUSTRADE, TYPE TBC
M DESIGN. scale (A3): drawing no:
t. 07 5471 2721 Sunshine Beach QLD I RELOCATED LDR'Y CBD, AMENDED GFA, 07.10.16 WC WATER CLOSET BAL 2 FRAMELESS GLASS BALUSTRADE
t. 0422 969 645 AMENDED SITE COVERAGE SG SHOWER GRATE SCR VERTICAL TIMBER SCREEN 1 : 100 2.2
Page 4
1
5.1
4.1
2
2600 450 600 600
600 DP GU
DP2 ROOF BELOW
600
t
ps
t
600
ps
1640
GU DP
LINE OF WALL BELOW
DP
600
LINE OF BEAM BELOW
LINE OF WALL BELOW
LINE OF WALL BELOW
LINE OF BEAM BELOW
1 4.2
TRIMDEK @2°
t
ps
2 2
GU
5.1 5.1
GU
TRIMDEK @2° TRIMDEK @2°
LINE OF WALL BELOW
ROOF BELOW
TRIMDEK @2°
t
4.1 1 ps
LINE OF BEAM BELOW
LINE OF WALL BELOW
600
LINE OF WALL BELOW
DP
1640
t
ps
600
t DP
ps LINE OF WALL BELOW
600
DP2
ROOF BELOW
DP GU
2
rth
4.2
o
1
n
5.1
ROOF PLAN - PROPOSED
0 1 2 3 4m
1 : 100 1:100
ISSUE: NOT FOR CONSTRUCTION sheet title:
M Design
© COPYRIGHT 2016 - M DESIGN Proposed Duplex: REV DESCRIPTION DATE
PO Box 290
THE IDEAS AND CONCEPTS
CONTAINED WITHIN THIS For: G RE-ISSUE FOR APPROVAL 05.09.16
-
ROOF PLAN
Peregian Beach QLD 4573 I RELOCATED LDR'Y CBD, AMENDED GFA, 07.10.16
DOCUMENT AND THE DOCUMENT
ITSELF REMAIN THE INTELLECTUAL Geoff Connan AMENDED SITE COVERAGE NOOSA COUNCIL job no: drawn by:
PROPERTY OF M DESIGN AND MAY
NOT BE COPIED OR REPRODUCED APPROVED PLAN 1626 LBW
IN PART OR IN WHOLE WITHOUT Project Address: date:
BSA No. 1066058 EXPRESSED WRITTEN PERMISSION
38 Elanda Street,
MCU16/0049 & OPW16/0109 14.07.16
FROM MICHAEL BROEREN OF
Contact: Michael Broeren
t. 07 5471 2721
M DESIGN.
Sunshine Beach QLD 6 DEC 2016 scale (A3): drawing no:
t. 0422 969 645 1 : 100 2.3
Page 5
8M HEIGHT LIMIT 2
5.1
CL2 HIGHTLIGHT GLAZING
FC CLADDING, TIMBER COVER STRIPS
2700
FC CLADDING, TIMBER COVER STRIPS
LEVEL 2
350
CL1
COLUMN
2700
BIN STORE
LEVEL 1
FEATURE ENTRY DOOR GARAGE TILT A DOOR, FINISH TO
WITH GLAZED MATCH TIMBER CLADDING
SIDELIGHT
NORTH ELEVATION
1 : 100
1 8M HEIGHT LIMIT
CLOTHES LINE & SCREEN SHOWN DASHED FOR CLARITY 5.1
FC CLADDING, TIMBER COVER STRIPS
FEATURE FC AWNING
FC CLADDING, TIMBER COVER STRIPS
POST
CL2
2700
WATER FEATURE
FC CLADDING, TIMBER COVER STRIPS
LEVEL 2
350
CL1
COLUMN
2700
BIN STORE
TIMBER CLADDING
LEVEL 1
VERTICAL SCREEN
EAST ELEVATION
1 : 100
0 1 2 3 4m
1:100
ISSUE: NOT FOR CONSTRUCTION sheet title:
M Design
© COPYRIGHT 2016 - M DESIGN Proposed Duplex: REV DESCRIPTION DATE
PO Box 290
THE IDEAS AND CONCEPTS
CONTAINED WITHIN THIS For: A CLIENT REVIEW 26.07.16 -
ELEVATIONS
Peregian Beach QLD 4573 C CLIENT REVIEW 24.08.16
DOCUMENT AND THE DOCUMENT
ITSELF REMAIN THE INTELLECTUAL Geoff Connan D FOR APPROVAL 25.08.16 NOOSA COUNCIL job no: drawn by:
PROPERTY OF M DESIGN AND MAY E RE-ISSUE FOR APPROVAL 30.08.16
NOT BE COPIED OR REPRODUCED F CHANGED WINDOWS 31.08.16 APPROVED PLAN 1626 LBW
IN PART OR IN WHOLE WITHOUT Project Address: I RELOCATED LDR'Y CBD, AMENDED GFA, 07.10.16
date:
BSA No. 1066058 EXPRESSED WRITTEN PERMISSION
AMENDED SITE COVERAGE
MCU16/0049 & OPW16/0109 14.07.16
FROM MICHAEL BROEREN OF 38 Elanda Street,
Contact: Michael Broeren
t. 07 5471 2721
M DESIGN.
Sunshine Beach QLD 6 DEC 2016 scale (A3): drawing no:
t. 0422 969 645 1 : 100 4.1
Page 6
2
8M HEIGHT LIMIT 5.1
CL2
FC CLADDING, TIMBER COVER STRIPS
2700
LEVEL 2
350
CL1
WEATHERBOARD CLADDING
2700
LEVEL 1
PLUNGE POOL
SOUTH ELEVATION
1 : 100
1
5.1
CLOTHES LINE & SCREEN SHOWN DASHED FOR CLARITY
8M HEIGHT LIMIT
FC CLADDING, TIMBER COVER STRIPS FEATURE FC AWNING
CL2
POST
2700
FC CLADDING, TIMBER COVER STRIPS
SEMI FRAMELESS GLASS POOL FENCE
FC CLADDING, TIMBER COVER STRIPS
LEVEL 2
350
CL1
COLUMN
2700
BIN STORE
LEVEL 1
VERTICAL SCREEN
TIMBER CLADDING WEATHERBOARD CLADDING
WEST ELEVATION
1 : 100
0 1 2 3 4m
1:100
ISSUE: NOT FOR CONSTRUCTION sheet title:
M Design
© COPYRIGHT 2016 - M DESIGN Proposed Duplex: REV DESCRIPTION DATE
PO Box 290
THE IDEAS AND CONCEPTS
CONTAINED WITHIN THIS For: A CLIENT REVIEW 26.07.16 -
ELEVATIONS
Peregian Beach QLD 4573 C CLIENT REVIEW 24.08.16
DOCUMENT AND THE DOCUMENT
ITSELF REMAIN THE INTELLECTUAL Geoff Connan D FOR APPROVAL 25.08.16 NOOSA COUNCIL job no: drawn by:
PROPERTY OF M DESIGN AND MAY E RE-ISSUE FOR APPROVAL 30.08.16
NOT BE COPIED OR REPRODUCED F CHANGED WINDOWS 31.08.16 APPROVED PLAN 1626 LBW
IN PART OR IN WHOLE WITHOUT Project Address: I RELOCATED LDR'Y CBD, AMENDED GFA, 07.10.16
date:
BSA No. 1066058 EXPRESSED WRITTEN PERMISSION
AMENDED SITE COVERAGE MCU16/0049 & OPW16/0109 14.07.16
FROM MICHAEL BROEREN OF 38 Elanda Street,
Contact: Michael Broeren M DESIGN.
Sunshine Beach QLD 6 DEC 2016 scale (A3): drawing no:
t. 07 5471 2721
t. 0422 969 645 1 : 100 4.2
Page 7
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0049 & OPW16/0109
6 DEC 2016
[OCR of page images]
KJ
NOOSA COUNCIL
APPROVED PLAN
MCU16/0049 & OPW16/0109
6 DEC 2016
CROSSOVER TO BE IN
ACCORDANCE WITH COUNCIL
SPECIFICATIONS 125 SLAB.
00 SLAB ON GROUND TO DRIVEWAY.
NOTE: APPROX 800mm OF LOOSE SAND HAS BEEN FOUND ON THIS SITE, THIS MATERIAL IS TO
BE EXCAVATED AND REPLACED AND COMPACTED IN LAYERS TO A MINIMUM UNIFORM DENSITY
OF 98% COMPACTION. ALL FOOTINGS ARE THEN TO BE FOUNDED IN MATERIALS OF MINIMUM SAFE
BEARING CAPACITY l00kPa, ANY FILL MATERIAL BENEATH SLAB IS TO BE COMPACTED IN
LAYERS TO A MINIMUM UNIFORM DENSITY OF 98% STANDARD COMPACTION.
fot
(| LAYER F72 MESH 30 TOP COVER.
\ - - -
-|
|
|
7
Td
7
a
PFI [| [| [| [| [00 SLAB ON GROUND TO EXTERNAL AREAS.
| LAYER F72 MESH 30 TOOP COVER.
R FBI EB
7 |
P| LIE IL JL = LILICIL fe = 2 Ey |
a 7 7 PFI |
PFI | Pry —-——f| ~~ Ie a | | (2)
Y 3 m7 |p 7 | | ~ |
lo al | |b — | | | 450 MASS CONCRETE PIERS
| | QD pass | | ty | | MIN 300 PAST U/S OD POOL °
TI | |_| wes 1 | re [— EXCAVATION.
ce | _ _ RG? wo ao
r 4 @25e=qI 0%; eS I | | _ | |
—_ _ a Ors < K
[ abe = IE = Fle gp APR ql | | |
[2 ASAP > Oh Vig 9 x] | | |
v a) | — 4E— <0 FBI |
| el | — Ay | | | Cs
| | | | L —~—__yG___sAL Of
| | q - 5
ofl Pt B22 PL__B?_ L Lj fe SSS SS Sse ore
[CALL LE = EEE A eee |
l raz TT Pc WS SS SH SRG Fi
oe a
SFI
FBI of:
wv | ye
| 7 AY
b Se
TJ |
a _ TJ Cp
ol EB
| |
PFI
( | (al |O
|| |
a _
5
- EB
PFI
FOUNDATION DESIGN IS BASED ON REPORT No. 16/0258 BY GLOBAL TESTING PTY LTD.
REFER TO THIS REPORT FOR SOIL CONDITIONS EXPECTED ON SITE.
IF ACTUAL SOIL
CONDITIONS VARY SIGNIFICANTLY FROM THOSE IN THE REPORT. CONTACT ENGINEER FOR
RE-APPRAISAL OF FOOTING DESIGN,
CONFIRM ALL STEPS AND FALLS WITH ARCHITECTS DRAWINGS.
CJ - FULL HEIGHT CONTROL JOINT TO MASONRY.
FOOTING
PLAN
EXCAVATION FOR POOL SHALL NOT EXTEND BELOW A LINE DIPPING
AT 45° AWAY FROM THE NEAREST UNDERSIDE CORNER OF ANY
FOOTINGS. CONTACT ENGINEER IF UNCERTAIN.
BUILDER TO VERIFY LOCATION OF ALL SERVICES ON SITE
PRIOR TO ORDERING MATERIALS OR COMMENCING WORK.
LOCATION OF POOL TO BE VERIFIED ON SITE.
RIENMAC pty tt
CONSULTING CIVIL € STRUCTURAL ENGINEERS
SUNSHINE COAST OFFICE:
A.B.N, 52 010 666 430
A.C.N, 010 666 430
SUITE 5, FIRST FLOOR, SAINT CIRINO, 137 BRISBANE ROAD,
(PO BOX 144) MOOLOOLABA @LD 4557
Fax:- (07) 5444 1158
Phone:- (07) 5478 2500
Email:- [email protected]
Website: -
www ,rienmac biz
CLIENT:
GEOFF CONNAN
PROJECT:
PROPOSED DUPLEX
38 ELANDA STREET
SUNSHINE BEACH QLD 4567
DRAWING TITLE:
FOOTING PLAN
This drawing is not_to be copied or amended without written permission from Rienmoc Consul
PETER RIENECKER - RPEQ 2088
Designed: PLR|SCALES: 1:100
Engineer: PLR|DRAWN: LR |DATE: 15 NOV lé
LOT 158 |
COUNTY OF MARCH, PARISH OF WEYBA
NOOSA SHIRE COUNCIL 16436 52 P
REAL PROPERTY DESCRIPTION ¢ COUNCIL: JOB NUMBER DWG No. ISSUE
DO NOT SCALE OFF DRAWINGS. | AS |SHEET 2 OF 13 |CHECKED: PLR
Page 8
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0049 & OPW16/0109
6 DEC 2016
[OCR of page images]
| LAYER F72 FABRIC.
30 TOP COVER.
FORM KEY IN EDGE OF Ist POURED SLAB COAST
FACE OF SLAB WITH BOND PREVENTATIVE.
BOLSTER CUT SLAB (3Wx30D), FILL (eg. HYDROSEAL, FORMOIL).
JOINT TO 30mm BELOW SURFACE WITH
FOSROC EXPANDITE THIOFLEX 600G.
é
300 SUBGRADE TO BE COMPACTED TO 98%
STANDARD COMPACTION (TEST El.! ASI284).
EDGE THICKENING (ET)
TYPICAL TO ALL EDGES OF DRIVEWAY SLAB,
DISCONTINUE FABRIC 40mm FROM END.
100
50 SAND BED AND
SS SS”
FE “SOON Seay ry
CUT EVERY 2nd WIRE DIRECTLY UNDER
JOINT ¢ DEPRESS FABRIC LOCALLY.
0
\09
1
3 BAR FIITM.
50 BOTTOM COVER.
KEYED JOINT (KJ)
TOOLED JOINT (TJ)
ALTERNATIVELY: SAW CUT SLAB 3Wx30D WITHIN
24 HOURS OF CASTING SEAL AS ABOVE.
WATERPROOF MEMBRANE.
| LAYER F82 FABRIC.
30 TOP COVER.
F.S.L
3 BAR FIITM.
50 BOTTOM COVER.
RIO TIES @600 CRS.
F.B. DETAILS
DRIVEWAY SLAB ON GROUND DETAILS
NOOSA COUNCIL
APPROVED PLAN
MCU16/0049 & OPW16/0109
6 DEC 2016
BARRIER/SEM|-MOUNTABLE
KERB AND CHANNEL. }
FOOTPATH
300
NONSLIP
FINISH.
CONSTRUCTION
JOINT,
MOUNTABLE KERB
AND CHANNEL, ~~“
FOOTPATH
PROPERTY BOUNDARY
2700 MIN
ALTERNATIVE PROFILE.
DRIVEWAY
CROSSING PLAN
DRIVEWAY NOTES:
|. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL.
2, CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES,
3. CONCRETE DRIVEWAY TO BE 125mm THICK EXCLUDING ANY FINISH
TREATMENTS, eg, STAMPED CONCRETE FINISH.
4, CONCRETE SURFACE TOLERANCE TO BE 0-5mm, OVER 3 METRE
SECTIONS.
5. CONCRETE N25 IN ACCORDANCE WITH ASI379 AND AS3600.
6, REINFORCEMENT FABRIC TO ASI304, 50 TOP AND EDGE COVER, LAP
FABRIC 250.
7, APPROVED MATERIALS FOR CONSTRUCTION:- CONCRETE or ASPHALT.
8. EXPANSION JOINTS TO BE l0mm WIDE, FULL DEPTH CLOSED CELL CROSS
LINKED POLYETHYLENE FOAM (85-|50kg/m3) OR COMPRESSED
GRANULATED CORKBOARD, INSTALLATION TO MANUFACTURERS
INSTRUCTIONS.
9. ALL DIMENSIONS IN MILLIMETERS.
10. ONE ACCESS POINT TO BE CONSTRUCTED TO EACH LOT AS PER
STANDARD DRAWING.
Il. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF
CURVE,
12. ALL SERVICES NEED TO BE LOCATED PRIOR TO EXCAVATION.
42
DRIVEWAY DETAILS AND 3|7
NOTES TAKEN FROM COUNCIL =i
RESIDENTIAL DRIVEWAY Sis F72 MIN FABRIC.
DRAWING R-0050. 7
22;
et 3
SAND BED.
BARRIER,
SEMI-MOUNTABLE,
MOUNTABLE KERB ¢
CHANNEL OR INVERT
CROSSING,
DRIVEWAY CROSSING
SAW CUT AND BREAKOUT
BACK OF KERB AND
CHANNEL.
190 BLOCKWALL VY
\7) 4
NI2 VER BARS @400 CRS. LAP
500 WITH NI2 FROM FOOTING——7-*|
NI2 HOR BARS @400 CRS. LAP
450 WHERE REQ'D AND AT
CORNERS. lo
BLOCK WALL TO BE ON EDGE OF
FOOTING WHEN ON BOUNDARY.
3 BAR F8TM TOP &
BOTTOM. RIO LIGS
@600 CRS. C
3/NI2 Z BARS EACH
FACE 400 LEGS.
300
MAX
Z
2
FOOTING STEP
DETAILS
ABN. 52 010 666 430
CONSULTING CIVIL &
SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO,
[37 BRISBANE ROAD,
(PO BOx 144)
MOOLOOLABA @LD 4557
RIENMAC ery ito
A.C.N. 010 666 430
STRUCTURAL ENGINEERS
P:- (07) 5478 250d
F:- (07) 5444 lI58
Email:- info@rienmac. biz
[email protected]!
Web:- www.rienmac. bi:
CLIENT:
GEOFF CONNAN
PROJECT:
PROPOSED DUPLEX
38 ELANDA STREET
KKK
SUNSHINE BEACH @LD 4567
DETAIL
PETER RIENECKER - RPEQ 2088
a REAL PROPERTY DESCRIPTION # COUNCIL:
ts—o LOT 158
COUNTY OF MARCH, PARISH OF WEYBA
S NOOSA SHIRE COUNCIL
3B DRAWING TITLE:
| DETAILS
Qo oO
350 Designed: PLR ~~ Drawn: LR
SCALES: 1:20
SF | DETAI LS Engineer: PLR |DATE: 15 NOV 16
permnision fram Rlenmae Coaultng Engreers “| JOB NUMBER DWG No, | ISSUE
| DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 8 OF [3 |CHECKED: PLR
Page 9
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0049 & OPW16/0109
6 DEC 2016
[OCR of page images]
. Site 569m? NOTE:
: j dD ‘A Roof 277 m2 DEPENDING ON GROUND CONDITIONS AND_ IF
| = : REACTIVE SOIL IS FOUND ALL PENETRATIONS
! : 4 Drivewa 84 rm? ,
2 s y , VERTICAL AND HORIZONTAL SHALL BE DRAWING SCHEDU LE
Landscape 284 om PROVIDED WITH SWIVEL JOINTS AND
New impervious 361m? EXPANSION JOINTS. ALL SUBSURFACE DRAINS 3190-1 COVER SHEET
REQUIRE EXPANSION JOINTS AT 10m SPACING.
CATCHMENT AREAS 3190-2 STORMWATER DRAINAGE PLAN
STREET ADDRESS: NOTE:
THE NEW IMPERVIOUS AREA IS COMPARED TO THE 3190-3 STORMWATER CALCULATIONS
GREENFIELD SITE.
48 ELANDA STREET COMPARED TO THE PREVIOUS BUILDING THE NEW 3190-4 | EROSION & SEDIMENT CONTROL PLAN (ESC)
IMPERVIOUS CATCHMENT AREA SHALL BE UNDER
SUNSHINE BEACH NOOSA COUNCIL — —
REAL PROPERTY DESCRIPTION:
6 DEC 2016 m
CLIENT NAME: —_
|
G & B CONNAN \ ©
m | =
| 3
|
a : -
mo = = 2.
\=
pane, | se m
ooo: : ~ »
| 3
38 ELANDA ST a f1 ogy
DAVID LOW WAY ee So = \ — =
/ 54,68: —— - —- = — 52:16 52:29 52.29. -~ 51.86 51.51 a a) }
ELANDA ST 51.36151.59 52 62.20 52.23 3T98 51.95 * 51.845. +50.93 on
= x92. 5 IN
y~ a oe ‘ N,
: . + | i
51.7 V ——_—= \
9a J \ ny i = a =“
usS l 5 f ) [ XX 5
135g ay | B80, 4 | Uo UNIT2 | oe. 17)
PACIFIC AV RP48112 . S68 al _ ‘. 7 \. @
298 | ___/ "Fels sz2h'] Bl Vso a ROOF PLAN
{| = 7
| @
|
|
51.35 |
WILDFLOWER ST
51.76
aL ST \
| cp
BUP5193
— _ | \
m
SIGNED BY THE PRINCIPAL AND
SENIOR DESIGN ENGINEER
DR.—ING. REINHOLD KOENNING
LOCALITY MAP RPEQ7023
SCALE: NTS MSC, PHD, MEAUST, AHSCA
DATE AS PER TITLE BLOCK
SITE PLAN & EXISITNG SERVICES
DISCLAIMER — ENSURE ORIGINAL SIZE DRAWING IS USED
FOR ASSESSMENT, TENDERING AND CONSTRUCTION.
LEGEND GENERAL NOTES WATER SUPPLY Amd Description Date
Ron Water 3 Diameter 1. DO NOT SCALE FROM THESE DRAWINGS. 1. WATER SUPPLY DIAMETERS ARE NOTED IN "ID" UNLESS NOTED OTHERWISE
Existing Water t.0.8, Cleanout to surface 2, DO NOT RELY ON THESE DRAWINGS FOR ALIGNMENT AND LEVELS OF EXISTING INFRASTRUCTURE. 2. PIPEWORK SHALL BE IN ACCORDANCE WITH AS4020, FOR EXAMPLE: ABS (ACRYLONITRITE STYTRENE), PP (POLY PROPYLENE), PE
s Existing Sewer cu Capped junction 3, ITIS THE OBLIGATION OF THE CONTRACTOR AND/OR PLUMBING CONTRACTOR TO SURVEY ALL EXISTING SERVICES PRIOR TO (POLYETHYLENE) OR COPPER U.N.O.
Existing Storm water cv Conrol valve CONSTRUCTION. 3. WATER SUPPLY PIPEWORK SHALL BE @20 U.N.O. EXCEPTION: ONE FITTING ONLY MAY BE 915, MAX. LENGTH 3000 MM. HOT WATER PIPEWORK|
HD Existing House drain cs Cleaners sink 4. THE PLUMBING CONTRACTOR IS OBLIGED TO OBTAIN REAL SIZE PRINT OUTS (A1 U.N.O.) FOR THE PREPERATION OF TENDER. ANY SHALL BE LAGGED, HOT WATER RECIRCULATING LINES TO BE INSULATED WITH 20MM "ARMAFLEX" OR SIMILAR.
Sanitary Drainage Se Duct weceas panel CLAIMS REFERED TO AS "DRAWING COPIES" NOT READABLE SHALL BE REFUSED. 4, PROVIDE TEMPERING VALVES ON HOT WATER TO PERSONAL HYGIENE FIXTURES.
Grey Water DCV Double cheek valve 5. ALL KITCHEN, LAUNDRY & BATHROOM FITTINGS AND TOILETS SHALL COMPLY WITH THE MINIMUM WELS WATER RATING LEVEL 4 5, UNDERGROUND COPPER PIPEWORK SHALL BE "KEMLAGGED" OR OTHERWISE PROTECTED. UNDERGROUND PIPEWORK NOT UNDER
TTT TTT a ee. Een Eccentric Enlarger STAR (FORMER AAAA WATER CONSERVATION RATING AS PER AS/NZ6400). CONCRETE SLAB MAY BE POLYPIPE CLASS PN20. ONE SIZE LARGER THAN SHOWN.
oS = Foe ater Elev Dge Evevated Drainage 6. PROVIDE FLOW RESTRICTOR VALVES TO TAPS AND SHOWER ROSES WHERE REQUIRED. 6. EXPOSED PIPEWORK IN AMENITIES AREAS, SHALL BE CHROME PLATED.
Storm Water Drainage Fo Foleo ceiling 7. THE FLOW SHALL NOT EXCEED A MAXIMUM OF 9L/MIN. 7. SUBMETERS SHALL COMPLY WITH APPROVED DEVICES. REFER LOCAL AUTHORITY REGULATIONS. SUBMETERS SHALL BE LOCATED IN
Woon eee Fire FH Fire Hydrant 8. WATER SUPPLY AND SANITARY DRAINAGE HAS BEEN DESIGNED AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE Q'LD COMMON AREAS ONLY.
Agi Drain FHR Fire hose reel STANDARD SEWERAGE LAW, Q'LD STANDARD WATER SUPPLY LAW, THE NATIONAL PLUMBING, DRAINAGE CODE AS 3500, THE meus Noles Dale
FFL Finished floor level Q'LAND DEVELOPMENT CODE QDC, THE FIRE HYDRANT CODE AS2419, ALL RELEVANT AUSTRALIAN STANDARDS, AND THE BACKFLOW PREVENTION
Rain Water Ri ot Ce Hs eptor t REQUIREMENTS OF THE LOCAL AUTHORITY. 1. PROVIDE HOSE CONNECTION VACUUM BREAKERS TO ALL HOSE COCKS PROVIDE RPZD TO ANY IRRIGATION CONNECTIONS, For Development Approval
ain Water Riser GP Gully pt 9. THESE DRAWINGS ARE DIAGRAMMATIC ONLY AND SHALL BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURAL AND/OR HAZARD ZONES. For Building Approval x 26-10-16
Cold Water Riser GMH Gully Man Hole DRAWINGS, OTHER CONSULTANTS DRAWINGS, SPECIFICATIONS AND OTHER WRITTEN INSTRUCTIONS THAT MAY BE ISSUED 2. PROVIDE APPROVED BACK FLOW PREVENTION TO FIRE SERVICES, HYDRANT SUPPLY (TESTABLE SINGLE CHECK VALVE U.N.O.), For Tender
Down Pipe gv Gate valve DURING THE COURSE OF THE CONTRACT. ANY DISCREPANCIES SHALL BE REFERRED TO THE SUPERVISING OFFICER FOR ALL FIRE HOSE REELS WHICH MAY BE USED FOR OTHER THAN FIRE FIGHTING SHALL BE EQUIPPED WITH DOUBLE CHECK VALVES For Construction
Stack HW Hot water tion branch DECISION BEFORE PROCEEDING WITH THE WORK. CONTRACTOR'S SHALL VERIFY ALL FIXTURE LOCATIONS, INVERT LEVELS, (DCV) U.N.O. As Constructed
Vent Pipe HD House drain SURFACE LEVELS, AND COVER TO PIPES ARE CORRECT AND OBTAINABLE PRIOR TO COMMENCEMENT OF THE WORK. THE EXACT
@) © Group Vent HL High level LOCATION OF EXISTING, AND PROPOSED SERVICES, SHALL BE VERIFIED WITH THE RELEVANT AUTHORITY, OR OTHER TRADES AS COVERS & FRAMES
® Group Ven ic inspection Chamber APPLICABLE. FIRE STOP COLLARS TO BE USED ON ALL PLASTIC PIPEWORK PENETRATING FIRE RESISTANT CONSTRUCTION. COVERS & FRAMES.
Fduct Vent iL invert Level 1. COVERS SUBJECT TO VEHICULAR TRAFFIC TO BE 2535 CAST IRON, MEDIUM DUTY U.N.O.
Induct Vent io inspection opening 2. COVERS IN GRASSED OR CONC. AREAS TO BE 535 CAST IRON, CONCRETE INFILL LIGHT DUTY.
Hot Water Riser K&C Kalk w Gheprel 2 ©° Surface SANITARY DRAINAGE 3. COVERS IN PAVED AREAS TO BE 600 SQ. INFILL TO MATCH PAVING PATTERN. Hvd li wet
; Kae Kerb & Channe 1. UNDERGROUND PIPEWORK SHALL BE 100 PVC DWV, AND UPVC WHERE EXPOSED, MIN GRADE 1:60 U.N.O. 4. COVERS IN TILED AREAS TO BE AS FOR PAVED AREAS WITH BRASS EDGING. yaraulic
Om Fire Dropper NRV Non return valve 2, SUSPENDED PIPEWORK SHALL BE PVC CLASS DWV. 5. CONCRETE INFILL COVERS TO BE STAMPED "SWD" OR "SEW" AS APPROPRIATE.
(8) Fire Riser PB Path box 3. TRADE WASTE PIPEWORK TO GREASE TRAP SUSPENDED SHALL BE "COESPRENE" OR HDPE. \-
PLV Pressure limiting valve 4. UNDERGROUND SHALL BE VITREOUS CLAY OR HDPE. - Rei +A MliEAust AHISCA
Vv Valve PO Planter outiet 5. TRADE WASTE PIPEWORK TO OIL SEPARATOR SHALL BE HDPE, OR VITREOUS CLAY WITH'NITRILE” RUBBER RINGS. GRATINGS . . contact: Reinhold Koenning MicAus
he Hose Cock Ree Real propery aoe, hn 6. CLEANOUTS OR INSPECTION OPENINGS BROUGHT TO SURFACE IN PAVED OR CONCRETE AREAS, OR WITHIN BUILDINGS TO HAVE 1. CeO S SO COROT NON TER TO BE "FASTON, GATIC" OR APPROVED EQUAL DUTY TO MATCH MANUFACTURERS RECOMMENDATIONS Moffat Beach, QLD, 4551
RPZD Reduce Pressure Zone device BRASS CAPS, SEALED AND SCREWED. . email: [email protected]
een Eccentric Enlarger RWO Rai i tlet 2. TRENCH GRATE TO BE TRANSVERSE BAR. PH: (07) 5491 4333
en Fnlarcer RWH Rain water head 3. FLOOR WASTE GRATES TO BE CHROME PLATED BRASS CLIENT
9 sD Sanitary Drainage STORMWATER DRAINAGE
oO / et Saoce ‘evel 1. UNDERGROUND PIPEWORK SHALL BE 2100 PVC CLASS SW MIN GRADE 1:100 U.N.O. G & B CONNAN
ORG Overflow Relief Cully s/t Safe Tray 2. DOWNPIPES SHALL BE @100 PVC CLASS SW, U.N.O ON HYDRAULIC PLANS. FIRE SERVICE
Wat Si) Storm water drain 3. RAINWATER OUTLETS (RWO) AND PLANTER OUTLETS (PO) SHALL BE "GATIC WADE" OR SIMILAR, WITH MEMBRANE CLAMPS WHERE 1. ALL HYDRANT PIPEWORK TO BE IN ACCORDANCE WITH AS2419-2005 CLAUSE 6.8. ARCHITECT :
[JDO we water, td Tropped Tundish REQUIRED. 2, ALL HYDRANT PIPEWORK TO BE IDENTIFIED IN ACCORDANCE WITH AS1345. M DESIGN
“ TG Test gate 4. GULLY PITS SHALL BE CONCRETE BODY IN TRAFFICABLE AREAS AND POLY IN NON TRAFFICABLE AREAS U.N.O. 3. ALL HYDRANTS AND FIRE HOSE REELS SHALL HAVE A MINIMUM CLEARANCE (IN ALL DIRECTIONS) OF 100MM AROUND THE HANDWHEEL. \ J
sk Sink ty und ote tronverse bor 5. POLLUTION CONTROL MANAGEMENT SHALL COMPLY WITH THE RELEVANT STATE GOVERNMENT AND LOCAL POLCY 4. ALL HYDRANTS TO BE FITTED WITH THE VALVE OUTLET AT RIGHT ANGLES TO THE FACE OR WALL BEHIND IT. THE VAVLE OUTLET IS TO BE /proJect: 38 ELANDA STREET >
LT Laundry Tub Tat Trench grate longitudinal bar 6. WE DO NOT SUPPORT NOR DO WE SPECIFY FRONT HIGH GUTTERS TO BE USED FOR EAVES GUTTER SYSTEMS. HORIZONTAL OR SLOPING AT A MAXIMUM OF 35 DEGREES BELOW HORIZONTAL. SUNSHINE BEACH
GI aundry Tu TMV. Thermostatic. mbang. valve IF THE OWNER/DEVELOPER/BUILDER OPTS FOR FRONT HIGH GUTTERS THE FULL LIABILITY MOVES TO WHO EVER MADE THAT 5. EXTERNAL FEED HYDRANTS SHALL BE POSITIONED WITHIN 20M OF A ROAD, HARDSTAND OR THE LIKE TO WHICH THE FIRE AUTHORITY PUMP DUPLEX
Washing Vv Tempering valve DECISION AND CONSTRUCTION HYDRAULIC WILL NOT BE LIABLE FOR ANY FAILURE OF THE ROOF DRAINAGE SYSTEMS AT ANY TIME IN APPLIANCE HAS ACCESS.
fol wm Machine u/g Underground FUTURE EXTERNAL HYDRANTS SHALL BE POSITIONED NOT LESS THAN 10M FROM THE BUILDING UNLESS PROTECTED BY A CONSTRUCITON HAVING DRAWING TITLE:
S EWG Floor Waste Cull u/s Under slab / A FIRE RESISTANCE LEVEL OF NOT LESS THAN 90/90/90 EXTENDING AT LEAST 2M EITHER SIDE OF THE HYDRANT OUTLET, AND WHICH EVER
cor mest way Were Unless noted otherwise IS THE LESSER, 3M FROM THE GROUND LEVEL ADJACENT TO THE HYDRANT OR THE HEIGHT OF THE BUILDING.
GS Bn _- Basin aver Supely 7. FIRE AUTHORITY BOOSTER CONNECTIONS SHALL BE INSTALLED WITHIN 8M OF A ROAD, HARDSTAND OR THE LIKE TO WHICH THE FIRE Hi
AUTHORITY PUMP APPLIANCE HAS ACCESS.
C_)} sth Both Shr Shower 8. MATERIALS: <@100 CLASS 16 POLY / TYPE B COPPER IN GROUND. COVER SHEET )
TYPE B COPPER ABOVE GROUND.
. C) HWS Hot water system >/=@100 CLASS 18 BLUE BRUTE IN GROUND.
Eq FHR Fire Hose Reel FIRELITE ILG / TYPE B COPPER RISER/S
La «= ME_—s Water Meter CS Cleaners Sk 9. DO NOT USE GALVANISED FOR UNDERGROUND PIPE WORK.
Design | RK. | checked | ae [Date 28-10-16 | Dwg. No. AMD.
SCALE: 1 : 200 ON At UNo.| 1 of 5 3190-1 J
RPD:— LOT 158 RP 48112
Page 10
-
NOOSA COUNCIL
APPROVED PLAN
MCU16/0049 & OPW16/0109
6 DEC 2016
[OCR of page images]
NOOSA COUNCIL
APPROVED PLAN
MCU16/0049 & OPW16/0109
6 DEC 2016
159
mo
RP48112 se
CP Z133
BUP9902
7 _
o
e 49.30
PROVIDE 450X600 GRATED TRANSFER | ~ 49. 16
CHAMBER AND DISCHARGE VIA Soff m
#100 TO KERB&CHANNEL. REFER
DETAIL FOR KERB CONNECTION
#100 FROM ROOF DRAINAGE 50.55
JOIN ALL DOWN PIPES OF UNIT 2
t ARE PROPOSED FOR THIS /
iT 5 rT” DEVELOPMENT
v
L yA,
135
RP48112
INGROUND
PROPOSED
POOL
c
NO_ INFILTRATION MEASURES AS PER DETAIL
I
NOTE: / KERB & CHANNEL
L / )
ee Eis | /
2
PROVIDE 150 WIDE LIENAL
|
|
|
| ‘ N
\ \ 100uPVC
| L
TO THIS DRAINAGE LINE AND “S
DISCHARGE TO KERB&CHANNEL A > )
6
i Z = %O L
IL49.510
: \ | 6py deg L/sec
= en eS rrr rr H.66
W MUU LLL — a ee ee ee
_ NX 100uPVC 49.51 o.
lL °F Q20 FLOW=9.8L/sec | | 49.68
lL = P 8 / 3off #100 TO
SSS rt |
L \
DRAINAGE CHANNEL WITH | Be. —N
TRAFFICABLE, HEAVY DUTY, \ *O, Da
~~ CLASS D GRATE AND DISCHARGE Pe a
/ VIA 100 TO TRANSFER CHAMBER Ss
fh) —“(i—i—i—s—OOS—SM NN
Lt —_— SS
, / . e ce
sn
/ ° .
la a Ro
0 >= / mn ®
\ crwrererererererersnrr = = / 4 S
/ Q20 FLOW=9.8L/se aA oO ;
* ~ oeree: —_——_ _————— | ( “ SIGNED BY THE PRINCIPAL AND
° 5 4 DY SENIOR DESIGN ENGINEER
F q DR.—ING. REINHOLD KOENNING
E 3 7 dA RPEQ7023
\ 7 Co MSC, PHD, MEAUST, AHSCA
100 FROM ROOF DRAINAGE DATE AS PER TITLE BLOCK
JOIN ALL DOWN PIPES OF UNIT 1
TO THIS DRAINAGE LINE AND
DISCHARGE TO KERB&CHANNEL " DISCLAIMER — ENSURE ORIGINAL SIZE DRAWING IS USED
© FOR ASSESSMENT, TENDERING AND CONSTRUCTION.
[Amd Description Date
CP ;
BUP5193 +
m
m
m1 Issue Notes Date
For Development Approval
For Building Approval x 28-10-16
For Tender
p>
|§ For Construction
2000min o 5 As Constructed
Hot Dip Galvanised Kerb Fo
adaptor to match kerb
profile 8
J | +
(Py 7 r .
leh
—_ U U Hydraulic 3:
125 x 75 x 6mm Galvanised Notes: . Y~ >
MS section 1. UFVC ‘pipe to be 100mm heavy duty DWV contact: Reinhold Koenning MicAust AHSCA
class
. . PO Box 181
. sage 2. All steel works to be hot dip galvanised 4 2
Connection ‘itting 3. All joints on PVC pipe to be sealed with Moffat Beach, QLD, 4551 RPEQ# 7023
reter Detal solvent weld cement (type N or P), or emar [email protected]
__75min__75min rubber ring joint. ca PH: (07) 5491 4333
A :
. G & B CONNAN
VILLE
L Fitting for connection of #100 ARCHITECT :
cs IS uPVC pipe to 125 x 75 x 6mm
€ lS. MS section \ M DESIGN y,
06
s at (PRosect: 38 ELANDA STREET »
SECTION A - A SUNSHINE BEACH
Hot dip MS connection DUPLEX
A fitting or approved equivalent.
pipes to sealed with silicone or DRAWING TITLE:
DETAIL A mortar into fittings.
TYPICAL CROSS SECTION OF STORMWATER TO KERB STORMWATER i
NOT TO SCALE DRAINAGE PLAN )
Design RH, Checked | Ch [Date 28—10—16 | Dwg, No. AMD,
\ Scale: 1: 100 ON At UNo.| 2 of 5 3190-2 J
RPD:— LOT 158 RP 48112
Used in these records
Approved Plans MCU16/0049 & OPW16/0109.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file