Council archive · source document
Amended plans received 14.11.25 · 51983.3225.25
Plans and drawings: the text below has words only, no drawings.
PROVIDE POWER TO HP & VRF ELECTRICAL LEGEND
STAIR WELL LIGHTING TO INTERCONNECTED NO PROVISION FOR SOLAR
MAINS POWER - SUB BOARD/METER BOARD
BETWEEN LEVELS WITH 1 SENSOR PER LEVEL DATA CONNECTION BY OTHERS
LANDING. 3 WAY SWITCHING. SETTINGS ON/FF
PROVIDE POWER TO VRF UNITS TYP. PROVIDE POWER TO PROVIDE POWER
AUTO. LIGHTS ON 10 MINUTE TIMER CEILING FAN
REFER MECH DRAWINGS FOR DETAILS VRF TO LED MIRROR
EX EX MB RISER EX 240VAC DOWNLIGHT
3F
SMOKE DETECTOR - HARD WIRED
HEAD
VRFH
VRFH
VRFH
AB WALL LIGHT (TYPE VARIES REFER SCHEDULE)
VRF AB
EXHAUST FAN
D 3F 3F
D - DENOTES DUCTED TO OUTSIDE
AB
PROVIDE POWER 1650 TELEPHONE SOCKET OUTLET
TO LED MIRROR PENDANT LIGHTING
BY OWNER LIGHT / HEATER / EXHAUST
RH EXHAST 1650
W CT AB
HEAD
EX SPOT LIGHT
OV
EX
BULKHEAD
LED 3 LIGHT DIMABLE REFER TO SCHEDULE
HEAD
RH
2 2 DENOTES TWO WAY SWITCH
VRFH
TELEVISION ANTENNA OUTLET
REF
AB DOUBLE SOCKET OUTLET W = WEATHER PROOF
100V
PROVIDE POWER DOUBLE SOCKET OUTLET 100V
TO LED MIRROR
PROVIDE POWER TO SINK
DOUBLE SOCKET OUTLET (RECESSED BOX)
WASTE DISPOSAL.
RCP/Electrical - GF RCP/Electrical - 1F RCP/Electrical - 2F SINGLE SOCKET OUTLET
1 : 100 1 : 100 1 : 100 HARD WIRED SINGLE SOCKET OUTLET
ISO
ISOLATION SWITCH
POWERPOINT LOCATION HEIGHTS IN MM RECESSED FLOOR BOX DOUBLE SOCKET
W = EXTERNAL/WEATHER RATED
RISER LIGHT SWITCH ON STAIR LANDING BELOW LED
WALL SWITCHES 1100
NOTE COMMENTS RE 3 WAY AUTO/SENSOR
LIGHTING TO STAIRWELL LED STRIP LIGHT W = WEATHER PROOF
POWERPOINTS UNO 300
PROVIDE POWER TO MECHANISED ROOF TOP HATCH MOTORISED WINDOW BLINDS
ABOVE BENCH POWEROINTS (AB) 1100
W
AB
DISHWASHER POWERPOINT 750
ELECTRICAL SCHEDULE
HEAD
MICROWAVE POWERPOINTS (AB) 1500
TYPE COUNT
HEAD
MICROWAVE POWERPOINTS (BB) 700 BUNKER LIGHT WALL MOUNTED 2
FRIDGE POWERPOINTS 1850 CEILING FAN - REFER TO SCHEDULE 7
W DATA POINT 5
RANGEHOOD 1750
EX DATA POINT 3
VRFH
TV / DATA 300
2. DOUBLE GPO 1
DOUBLE GPO - USB 27
DOUBLE GPO - WEATHER PROOF 3
AB AB NOTES
EXHAUST FAN - CEILING MOUNTED 1
NOTE DESCRIPTION EXTERNAL SPOTLIGHT 2
PROVIDE POWER
TO LED MIRROR
RCP/Electrical - 4F CT COOKTOP ELECTRIC EXTERNAL WALL LIGHT 4
EX HARD WIRED SINGLE GPO 1
1 : 100 MB METER BOARD
RCP/Electrical - 3F OV OVEN
LED DOWNLIGHT 57
REF REFRIGERATOR SPACE PENDANT LIGHT - PROVISION ONLY 2
1 : 100 VRF VRF SYSTEM AIR CONDITIONING SINGLE GPO (CLIPSAL ICONIC) 7
VRFH SMOKE DETECTOR - HARD WIRED 9
TV OUTLET 2
NOTE - FINAL DETAILS FOR VRF A/C PENDING
Revision Description Date Issued By Building Class: 1 Sheet Name:
PROJECT DESCRIPTION
DESIGN & VERSION
CLIENT: B. & S. MAGANAY Climate Zone: 2
A1 CONCEPT PLAN 24.07.2025 MD
Wind: N4 (EQUIV)
ELECTRICAL PLANS
11/11/2025 1:49:48 PM
B1 PRELIMINARY DESIGN 29.07.2025 MD NAME ON TITLE: SHELLEY JEANETTE MAGNAY
B2 GENERAL AMENDMENTS 28.08.2025 MD ADDRESS: 3/30 HASTINGS STREET NOOSA HEADS BAL: LOW Project #: Sheet #: Rev:
C1 DETAILED DESIGN 16.09.2025 MD Soil Class: P
D1
E1
GENERAL AMENDMENTS
CONTRACT DRAWINGS
06.11.2025
11.11.25
MD
MD Lot 3 on GTP 1154 Corrosion: C5 1070 A08 E1
© QBCC Lic no. 15143813 Noosa Shire Council Acoustic: n/a Drawn By: MD Checked By: T.J. Scale: As indicated
See the original
The page text is free to read. Viewing or downloading an original file needs an account.