Council archive · source document
150401_Cg_Ldp_D_Tristania Drive LP101-301 · 132010.811.03
Attached to the e-mail 132010.811.03 Change to approval 22 Tristania Drive Marcus Beach.
PROPOSED 2 DUPLEXES - 20 & 22 TRISTANIA DRIVE MARCUS BEACH LOCATION MAP ars DRAWING SCHEDULE LP101 LOCATION MAPS, SCHEDULES & GENERAL NOTES. LP201 LANDSCAPE PLAN LP301 LANDSCAPE DETAILS PROJECT EXTENTS scate 1:250 100 105. UNIT 1 FRL T1975 Bed 3 Garage FrLi28 NIT 2 FFL 11975 Bed 3 UNIT FFL 11975 Bed 3 Garage Frvizs IT4 FFL 11975 Bed 3 Garage FrLi2s 120 125 oct} — Driveway Carport CO GR NLON OUP P 07 5478 3353 E [email protected] PLANT SCHEDULE CONTAINER C) SYMBOL CODE SPECIES/ DESCRIPTION SIZE/HEIGHT QTY TREES PAN TEC PANDANUS TECTORIUS 45LTR 4 SHRUBS Mi MAG LIT MAGNOLIA GRANDIFLORA 25LTR 26 KAY PARRIS (as) ACM SMI ACMENA SMITHII 200MM 51 (HA) HEL BIH HELICONIA BIHAI CLAW 2 300MM 43 (8) LIC ELE LICUALA ELEGANS 300MM 7 (4) LEP HOP LEPIDOZAMIA HOPE! 300MM 7 (zF) ZAM FUR ZAMIA FURFURACEA 200MM 16 GROUNDCOVERS ASP BUL ASPLENIUM BULBIFERUM 200MM 15 AUS DUL AUSTROMYRTUS DULCIS 200MM 5 He He ADJ AUS ADJUGA AUSTRALIS 140MM 114 | PLANTED AT 400MM C/S GROUNDCOVER MIX 1 SS SX \ MIX OF THE FOLLOWING PLANTS SPREAD EVENLY IN SPECIES ~\ CLUMPS OF SIX. N S LOM CON LOMANDRA CONFERTIFOLIA 200MM 25 PLANTED AT 500MM C/S ADJ AUS ADJUGA AUSTRALIS 140MM 25 PLANTED AT 500MM C/S DIA CAE DIANELLA CAERULEA 200MM 25 PLANTED AT 500MM C/S NOTE: ALL QUANTITIES TO BE CONFIRMED ON SITE BY CONTRACTOR. ALL TREES TO BE CERTIFIED BY A QUALIFIED ARBORIST AND TO BE NATSPEC COMPLIANT. QUALIFIED ARBORIST TO SELECT NATSPEC COMPLIANT TREES AT NURSERY AND CHECK ON DELIVERY TO SITE. TREES TO BE PRUNED AND TRAINED AS PER SPECIFICATIONS OUTLINED IN NATSPEC: GUIDE TO SPECIFYING TREES. GENERAL NOTES NOTE: THIS LANDSCAPE PLAN PACKAGE MUST BE READ IN CONJUNCTION WITH THE OPERATIONAL WORKS LANDSCAPING DECISION NOTICE. ALL WORKS TO BE DONE IN ACCORDANCE WITH THE APPROPRIATE AUSTRALIAN STANDARDS, THE PLANNING SCHEME LANDSCAPE CODE, IN ACCORDANCE WITH COUNCIL'S PLANNING POLICY, AND ALL OTHER RELEVANT STANDARDS. SITE WORKS THE CONTRACTOR SHALL: e INSTALL SILT CONTROL FENCING AS REQUIRED. e REMOVE ALL UNWANTED MATERIAL FROM SITE. e CONFIRM ALL DIMENSIONS ON SITE PRIOR TO CONSTRUCTION. e SEEK INSTRUCTION FROM SUPERINTENDENT WHERE LEVEL DISCREPANCIES AND POOR SOIL STRUCTURE OCCURS. e PRIOR TO LANDSCAPING WORKS COMMENCING ON-SITE, A PRE-START MEETING IS TO BE HELD WITH COUNCIL'S DELEGATE. SERVICES e THE CONTRACTOR SHALL CONFIRM THE LOCATION OF ALL SERVICES WITH RELEVANT AUTHORITIES PRIOR TO PLANTING AND EXCAVATION. e ALL TREES MUST BE PLANTED A MIN. OF 1.5M FROM WATER SUPPLY SYSTEMS AND SEWAGE SYSTEMS, MIN 8M FROM OVERHEAD STREET LIGHTING, MIN 2.5M FROM ELECTRICITY OR TELEPHONE POLES OR PILLARS AND MIN 3.5M FROM POWERLINES. DRAINAGE e ENSURE DRAINAGE WORKS CORRELATE WITH ADJACENT LAND AND SPECIFIED FINISHED LEVELS. e SUPPLY 100MM @ 'AG' PIPE CENTRALLY LOCATED WITHIN A 300x300MM DRAINAGE GRAVEL TRENCH ENCASED WITH GEOTEXTILE FABRIC TO ALL GARDEN BEDS AND CONNECT TO STORM WATER. GENERAL PLANTING PLANT STOCK IS TO BE APPROVED BY CONTRACTOR AND QUALIFIED ARBORIST PRIOR TO ACCEPTANCE OF DELIVERY. MULCH BED AREAS SHOULD NOT EXCEED A 1:3 GRADE. WHERE SLOPES ARE GREATER THAN 1:3 INSTALL BIODEGRADABLE MULCH RETAINING NETTING. WHERE SLOPES ARE GREATER THAN 1:3 INSTALL JUTE MESH PRODUCT TO MANUFACTURERS SPECIFICATION. CULTIVATE SUBGRADE TO A DEPTH OF 300MM AND TREAT WITH 150MG/M2 OF GYPSUM. INSTALL SPECIFIED TOPSOIL (MINIMUM 300MM) AND CROWN BED AT CENTRE. MULCH GARDEN BEDS TO A DEPTH OF 100MM WITH HOOP PINE BARK MULCH OR APPROVED SIMILAR AS SPECIFIED IN DETAIL. ENSURE MULCH THE FINISHED MULCH LEVEL |S SET DOWN SLIGHTLY FROM ADJOINING SURFACES SUCH AS THE KERB SO THAT MULCH IS CONTAINED. EXISTING GARDEN BEDS TO BE CULTIVATED SHOULD BE AT KERB HEIGHT. EXCESSIVE SOIL TO BE REMOVED. e NO SYNTHETIC, GRANULAR BLENDED FERTILIZERS TO BE USED ON SITE. SLOW RELEASE ORGANIC TREE TABLETS SHALL BE USED AT ESTABLISHMENT. e ALL PLANTINGS SHALL INCORPORATE THE INCLUSION OF A SLOW RELEASE NATIVE PLANT FERTILIZER (AS PER MANUFACTURERS SPECIFICATION) AND THE USE OF A SOIL MOISTURE RETENTION ADDITIVE (AS PER MANUFACTURERS SPECIFICATION), PLACED ADJACENT TO THE PLANT ROOT BALL AT THE TIME OF PLANTING. e GARDEN BEDS WITH EXISTING VEGETATION SHOULD BE CULTIVATED AND REWORKED WHERE POSSIBLE BY HAND TOOL WITHIN ROOT ZONES) TO A MINIMUM DEPTH DEPTH OF 150MM. GARDEN BEDS TO BE LOWERED TO KERB LEVEL WHERE POSSIBLE. GARDEN BED HEIGHTS TO BE MAINTAINED FOR EXISTING VEGETATION. TOPSOIL ¢ GENERALLY ALLOW FOR AMELIORATED SITE TOPSOIL TO, GARDEN BEDS, STREET VERGES AND SWALES IN ACCORDANCE WITH SOIL TEST REPORT. e INSTALL APPROVED IMPORTED TOPSOIL (TO COMPLY WITH AS4419) TO ALL GARDEN BEDS IF AMELIORATED SITE TOPSOIL IS NOT AVAILABLE. * WHERE SITE SOIL IS TO BE USED AS TOPSOIL, AMELIORATE SITE SOIL AS SPECIFIED BY THE SOIL TESTING LABORATORY. ALL SOIL STOCKPILES ARE TO BE MAINTAINED TO CONTROL WEEDS ROUTINELY AND GUARD AGAINST DISPERSION BY WIND OR WATER. STOCKPILES SHALL BE LIMITED TO A MAX. HEIGHT OF 2m AND MAY REQUIRE COVERING OR RETAINING. STOCKPILES ARE NOT PERMITTED WITHIN CLOSE PROXIMITY TO RESIDENTIAL PROPERTIES. ¢ GENERALLY SOIL TO BE USED SHALL COMPLY WITH THE FOLLOWING SPECIFICATION: (1) FRIABLE AND MODERATELY FREE DRAINING. (2) COMPLIES WITH AS4419. (3) ACCEPTABLE CONDUCTIVITY AND PH LEVELS FOR INTENDED PLANT SPECIES TO BE PLANTED. (4) IS FREE OF FIRE ANTS. (5) IS FREE FROM NUT GRASS (CYPERUS ROTUNDUS). MINIMUM DEPTH OF TOPSOIL FOR A GARDEN BED IS 300MM. MINIMUM DEPTH OF TOPSOIL FOR A TURFED AREA IS 50MM. EXISTING TREES TO BE RETAINED e EXISTING TREES TO BE RETAINED AND PROTECTED AS NOMINATED INDICATIVELY ON PLANS. LOCATIONS TO BE CONFIRMED ON SITE BY CONTRACTOR. ALL CULTIVATION WORKS WITHIN PROTECTION ZONES (CANOPY) TO BE PREPARED BY HAND TOOLS ONLY(NON MECHANICAL MEANS) AND IN ACCORDANCE WITH PROTECTION GUIDLINES. ANY REQUIRED TRIMMING OR PRUNING WORK TO BE CARRIED OUT IN ACCORDANCE WITH AS 4373 (OR ANY LATER VERSION OF THIS STANDARD). FOR FURTHER DETAIL ON EXISTING TREE REQUIREMENTS REFER TO COUNCILS DECISION NOTICE. VEGETATION REMOVAL e REFER TO COUNCIL DECISION NOTICE FOR FOR REQUIREMENTS. MULCH e ALLMULCH PROPOSED TO BE USED ON SITE SHALL BE FREE OF FOREIGN MATTER INCLUDING ANTHROPOGENIC WASTE, ROCK, SOIL, SEDIMENT CONTAMINATION, WEEDS AND STICKS. e _ALLLANDSCAPE PLANTING AREAS OR INDIVIDUAL PLANTED TREES/SHRUBS ARE REQUIRED TO BE MULCHED TO A MINIMUM DEPTH OF 100MM. e INSTALL HOOP PINE BARK MULCH OR APPROVED SIMILAR TO ALL LANDSCAPE PLANTING AREAS AND INDIVIDUAL PLANTED TREES/SHRUBS. PAVING & HARD SURFACES e REFER TO ARCHITECTURAL DRAWINGS. GARDEN EDGES e ALUMINIUM EDGING TO BE AMBER PRODUCT TYPE: 'THE LINK EDGE' OR SIMILAR IN LOCATION SHOWN ON PLANS WITH 300MM SPIKES AT 3 PER 3M LENGTH. REFER TO DETAIL. e CONCRETE EDGING TO BE 150MM WIDE IN LOCATIONS SHOWN ON PLANS. INTEGRALLY COLOURED COLOUR TYPE TO MATCH INTERNAL PEDESTRIAN PAVEMENT AREAS. INTERNAL TURF AREAS e TURF TYPE: ZOYSIA MATRELLA. ' LAID ON 100MM OF TYPE A TOSOIL AS DETAILED. EXTERNAL TURF AREAS e TYPE: CYNODON DACYLON 'COUCH' LAID ON 100MM OF TYPE A TOSOIL AS DETAILED TO ALL VERGE AREAS THAT HAVE BEEN DISTURBED. GARDEN BOULDERS INSTALL 500-1000MM DIAMETRE NATURAL ROUNDED BOULDERS IN LOCATIONS SHOWN ON DRAWINGS. TYPE OF BOULDER TO BE MALENY BUSH ROCK SOURCED FROM PARTON EXCAVATIONS 190 ENSEBEY ROAD MALENY 4552, CONTACT - RAY PARTON - PH 0414842378 OR SIMILAR. IRRIGATION e THESE LANDSCAPE PLANS ASSUME ALL LANDSCAPED AREAS INCLUDING INTERNAL TURF WILL BE IRRIGATED AUTOMATICALLY TO APPROPRIATE STANDARDS AND INSTALLED BY A SUITABLY QUALIFIED PERSON TO THE MANUFACTURERS SPECIFICATION AND HAVE A MINIMUM 12 MONTH WARRANTY. GENERAL e FOR MORE DETAIL REFER TO THE ARCHITECT'S, AND ENGINEERS DRAWINGS. e PLANTING SHOWN REFLECTS THE DESIGN INTENT, EXACT NUMBERS AND LOCATIONS WILL REQUIRE CONFIRMATION ON SITE BY THE SUPERINTENDENT. ANY CHANGES TO BE MADE TO THE LANDSCAPE PLAN MUST BE APPROVED BY THE LANDSCAPE ARCHITECT AND SUPERINTENDENT. ALL STRUCTURES TO BE APPROVED BY THE APPROPRIATE GOVERNMENT DEPARTMENTS PRIOR TO ANY CONSTRUCTION TAKING PLACE. ALL LANDSCAPE PLANS PRESENTED ASSUME THAT ALL SURVEY AND BASE INFORMATION IS ACCURATE AND TO SCALE. THE CONTRACTOR SHALL CHECK THE LANDSCAPE PLANS PRESENTED FOR ANY DISCREPANCIES WITH THE EXISTING SITE CONDITIONS OR OTHER DRAWINGS PRESENTED PRIOR TO ANY CONSTRUCTION WORK TAKING PLACE. IF DISCREPANCIES DO OCCUR THESE SHALL BE HIGHLIGHTED AT ONCE TO THE SUPERINTENDENT PRIOR TO ANY CONSTRUCTION TAKING PLACE. MAINTENANCE TASKS 1. IRRIGATION AND WATERING e EVERY 2-3 DAYS DURING THE ESTABLISHMENT PERIOD. e ONCE A WEEK THERE AFTER. 2. MOWING e AS REQUIRED TO MAINTAIN A TIDY AND EVEN GRASS HEIGHT. 3. WEED REMOVAL AND WICK WIPING e AS REQUIRED TO REDUCE COMPETITION AND SEEDING. 4. REMULCHING e AS REQUIRED TO MAINTAIN A CONSISTENT DEPTH UNTIL PLANTS ARE ESTABLISHED. 5. MONITORING e PROVIDE A MONTHLY REPORT ON COMPLETED TASKS. MAINTENANCE e MAINTAIN WHOLE OF LANDSCAPE WORKS FOR ESTABLISHMENT PERIOD OF 13 WEEKS FROM DATE OF PRACTICAL COMPLETION OF LANDSCAPE WORKS. e ALLLANDSCAPED PUBLIC AREAS MUST BE MAINTAINED TO THE APPROVED STANDARD, IN ACCORDANCE WITH CURRENT PROVISIONS AND SPECIFICATIONS OF COUNCIL'S DEVELOPMENT DESIGN PLANNING SCHEME POLICY. DATE 01.04.15 01.04.15 31.03.15 27.03.15 rwDoU ISS DESCRIPTION CHKD | CLIENT PROJECT LANDSCAPE DOCUMENTATION PACKAGE PROJECT. NO. DWG. NO. ISSUE FOR OF WORKS APPROVAL "c| AL TUM CONSTRUCTIONS |2 DUPLEXES - 20 & 22 TRISTANIA |LOCATION MAPS, SCHEDULES & | 353 FOR CONSULTANT REVIEW Mc DRIVE MARCUS BEACH GENERAL NOTES wesw) LP101 D © COPYRIGHT tis pRAWING Is COPYRIGHT AND THE PROPERTY OF CONLON GROUP PTY. LTD. AND MUST NOT BE RETAINED, COPIED/REPRODUCED OR USED WITHOUT WRITTEN AUTHORITY. FOR OPERATIONAL WORKS APPROVAL
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
Benth Seat
i + a4. | i
Loe ge.
saya
ee : \ . . : fra .
I 18th High \ ef | Water =
41 | Fence: J.
: \ Tan Je
Fehcé ag ae
Type 2 Up’ <4. :
Blpck
Retaming
Wall:
al
a
4} +f ~~} +f
i: UNIT 1 UNIT 2 UNIT 3 UNIT 4 1.8
0 FFL 11.975 FFL 11.975 FFL 11.975 FFL 11.975 yo 8
O Wo
3 Existing Bed 3 Bed 3 Bed 3 Bed 3 Jes
| Stormw. tery
Existing II Pipe
Building. | (
| 7 |3
|
|
11.5 I
|
|
—_I Exist
Bath Building.
12.0
== |
4m Wide |
Overland
Existing Flow Path | Garage Garage Garage
Building.
carage FFL 12.5 __ FFL 12.5 FFL 12.5
| [a
| FFL 12.5 | |
_I
Meter Box Dp
be
k— Existing
<i Boundary , <2 /
Driveway | Line , |
AS AS AS l2}escage Siri? AS
5
QD
m
LEGEND
EXISTING TREES
TO BE RETAINED AND PROTECTED. REFER TO
GENERAL NOTES.
TURF
REFER TO GENERAL NOTES FOR DETAIL.
PROPOSED TREES
REFER TO GENERAL NOTES, DETAILS AND PLANT
SCHEDULE.
PROPOSED HEDGE
REFER TO GENERAL NOTES, DETAILS AND PLANT
SCHEDULE.
PROPOSED SHRUBS
REFER TO GENERAL NOTES, DETAILS AND PLANT
SCHEDULE.
PROPOSED GROUNDCOVERS
REFER TO GENERAL NOTES, DETAILS AND PLANT
SCHEDULE.
CONCRETE GARDEN EDGE
REFER TO GENERAL NOTES AND DETAIL.
ALUMINIUM GARDEN EDGE
REFER TO GENERAL NOTES AND DETAIL.
GARDEN BOULDERS
REFER TO GENERAL NOTES.
ORGANIC STEPPER
REFER TO BUILDER'S DETAILS.
CONCRETE PAVEMENT
REFER TO BUILDERS DETAILS.
12.0 15° 08' 00"
12.0
12.5
en ae eT 80
oe — — — — — —_ ——
CO N L O N O1.04.15 nad FOR OP WORKS APPROVAL ore oy PROJECT LANDSCAPE DOCUMENTATION PACKAGE PROJECT. NO. DWG. NO. ISSUE
Ooms OR OP Woke APPROVAL wc| ALTUM CONSTRUCTIONS 2 DUPLEXES - 20 & 22 TRISTANIA LANDSCAPE PLAN 353 6) LP201 D
GROUP SSUES FRESE MS DRIVE MARCUS BEACH m0
P07 5478 3353 E [email protected] © COPYRIGHT tuis nrawine Is COPYRIGHT AND THF PROPERTY OF CONI ON GROUP PTY. 1 TD. AND MUST NOT BF RETAINED. COPIEDIRFPRONUCEN OR USED WITHOUT WRITTEN AUTHORITY
FOR OPERATIONAL WORKS APPROVAL
Page 3
HESSIAN 50MM WIDTH
PLAN VIEW - STAKE
POSITIONING AND HESSIAN
LOOP - EXAMPLE WHEN
PREVAILING WIND IS SOUTH
EAST
1M WIDE MULCHED COLLAR
NOTES:
ROOT BARRIER TO BE APPLIED UNLESS
OTHERWISE SPECIFIED TO IRC APPROVAL.
IRRIGATION SYSTEM AS SPECIFIED.
INSTALL PVC AG-PIPE SUBSOIL DRAINAGE AS
SPECIFIED REFER TO DETAIL.
STAKE SIZES FOR PLANT SIZES:
SIZE STAKE
45LITRE 50X50MM
JOOLITRE 75X75MM
200/400LITRE 100X100MM
ADVANCED TREE AS SPECIFIED. REFER TO
MULCHED GARDEN BED AS
SPECIFIED.
"LINK EDGE' 5MM ALUMINIUM EDGE.
TURF AS SPECIFIED.
Yi
—- iy
100MM OF TOPSOIL AS SPECIFIED. Yi Y ij
A
EXISTING SUBGRADE. ——+
300MM SPIKES AT 2 PER 1M.
MULCHED GARDEN BED AS
DETAILED.
SUBGRADE. ——+
NOTE
FSL
150mm CULTIVATED SUBGRADE.
300mm TOPSOIL AS SPECIFIED.
MULCH AS SPECIFIED SET 10MM
BELOW EDGING.
150X150MM CONCRETE EDGE WITH WOOD
FLOAT FINISH. ENSURE EDGE FINISHES
FLUSH WITH ADJACENT FSL, 20MPA TO
APPROVED LCC STANDARDS.
e ALIGNMENT OF THE EDGE ISA
CONTINUOUS WAVE OR STRAIGHT LINE
AS SHOWEN ON DRAWINGS, CURVES
ARE LAID OUT SO THAT RADII ARE
SMOOTHLY CONCRETED.
CONTROL JOINTS ON 2M CENTRES AND
AT THE APEX OF THE CURVES.
EDGES ARE TROWEL FINISHED TO THE
APPROVED PROFILE.
COMPACTED SUBGRADE TO
APPROVED LCC STANDARDS.
SUBGRADE MATERIAL IS FREE FROM EXTRANEOUS MATERIAL THAT
PREVENTS EVEN COMPACTION AND CAUSES SUBSIDENCE.
(02\ TYPICAL DETAIL ALUMINIUM EDGE
(03\ TYPICAL DETAIL CONCRETE MOWING EDGE
PLANTING PLAN, SCALE 1:10 SCALE 1:10
REFER TO TABLE FOR STAKE SIZES. STAKES TO
BE F14 HW NON-TREATED STAKES FREE FROM
KNOTS AND WARPS ETC. STAKES TO BE DRIVEN
IN TO HEIGHT TO ENSURE STAKE DOES NOT
DAMMAGE LOWER LIMBS. STAKES TO BEDRIVEN
CENTRALLY POINTED AND DRIVEN VERTICALLY
INTO GROUND OUTSIDE OF ROOTBALL. LOCATE
<;]-————— PLAN VIEW.
50MM WIDTH HESSIAN SECURED LOOSELY TO
TREE AND FIXED TO STAKE WITH GALVANIZED
FLAT HEAD NAILS. HEIGHT OF TIE TO BE ONE
THIRD TO ONE HALF THE OVERALL HEIGHT OF
TREE. REFER TO PLAN VIEW.
100MM DEEP MULCH COLLAR TAPERED DOWN IN
CENTRE TO FORM WATERING BASIN.
y POTS. SHRUBS AND GROUNDCOVERS AS
| TREE PIT TO BE EXCAVATED TO DEPTH OF SPECIFIED.
ROOTBALL, BACKFILLED WITH 50% SOIL AND
POU D. MAXIMUM 2% ORGANIC CONTENT, FIRMING SPECIFIED SET VERTICAL REFER TO
MUU {la © PROSESSNEY PLANS AND PLANT SCHEDULE
nes < SCARIFY ALL SIDES OF PLANTING PIT. AND
< BS ENSURE ALL SIDES ARE POROUS. RIP CLAY 100MM OF MULCH AS SPECIFIED.
SURFACES. ENSURE MULCH 25MM MIN
DEPTH WATER CRYSTALS AS SPECIFIED. APPLIED PER ITTLLILT- CLEAR OF PLANT STEM.
DEPTH. MANUFACTURERS RECOMMENDATIONS. AVOID a | MINIMUM 300MM DEPTH OF FIABLE IMPORTED
| PLACING UNDER ROOT BALL. mn ae = TOP SOIL OR AMENDED SITE SOIL AS
SPECIFIED (LIGHTLY COMPACTED ONLY, MAX
SLOW RELEASE FERTILISER AS PER . (| 2% ORGANIC CONTENT).
MANUFACTURERS SPECIFICATION. e
° Ge Ne SLOW RELEASE NATIVE FERTILISER AS PER
CULTIVATE SUBGRADE TO 150mm DEPTH. be aa MANUFACTURERS RECOMMENDATIONS.
foe WATER CRYSTALS AS PER MANUFACTURERS
EXISTING SUBGRADE. x SPECIFICATION (AVOID PLACING UNDER ROOTBALL).
CULTIVATE SUBGRADE TO A DEPTH
OF 150MM.
GENERALLY 2X WIDTH EXISTING SUBGRADE.
OF ROOTBALL
(01\ PLANTING DETAIL ADVANCED TREES (04\ PLANTING DETAIL SHRUBS AND GROUNDCOVERS
ay, SCALE 1:20 \Y SCALE 1:20
C O N [ O N DATE ISS DESCRIPTION CHKD | CLIENT PROJECT LANDSCAPE DOCUMENTATION PACKAGE PROJECT. NO. DWG. NO. ISSUE
O04 16 G FOR OP WORKS APPROVAL wc | ALTUM CONSTRUCTIONS 2 DUPLEXES - 20 & 22 TRISTANIA LANDSCAPE DETAILS 353 - LP301 D
31.03.15 B FOR CONSULTANT REVIEW MC
G R O U p 27.03.15 A FOR CONSULTANT REVIEW MC DRIVE MARCUS BEACH AT AS SHW
P 07 5478 3353 E [email protected]
© COPYRIGHT tis pRAWING Is COPYRIGHT AND THE PROPERTY OF CONLON GROUP PTY. LTD. AND MUST NOT BE RETAINED, COPIED/REPRODUCED OR USED WITHOUT WRITTEN AUTHORITY.
FOR OPERATIONAL WORKS APPROVAL
Used in these records
150401_CG_LDP_D_TRISTANIA DRIVE LP101-301.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.