Original source · versioned page text
20.025_20 Cooran Court Jetty & RevWall_Form 15_C4
Attached to the e-mail Combined Application MCU21/0112 & OPW21/0183 - DA Form 1 - State Consent Letter - Form 15 - Title seach - Survey Plan - 20 Cooran Crt, Noosa Heads.
Department of Housing and Public Works
Form 15—Compliance certificate
for building design or
Version 4 – July 2017
specification
NOTE: This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the
Building Regulation 2006.
RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether building work
complies with the BCA or a provision of the Queensland Development Code (QDC). A building certifier (Class B)
can not give a certificate regarding QDC boundary clearance and site cover provisions.
1. Property description Street address (include no., street, suburb/locality and postcode)
This section need only be 20 Cooran Court
completed if details of street
address and property description Noosa Heads QLD Postcode 4567
are applicable.
E.g. in the case of Lot and plan details (attach list if necessary)
(standard/generic) pool design/shell Lot 228 N21857
manufacture and/or patio and
carport systems this section may In which local government area is the land situated?
not be applicable. Noosa Council
The description must identify all
land the subject of the application.
The lot and plan details (e.g.
SP/RP) are shown on title
documents or a rates notice.
If the plan is not registered by title,
provide previous lot and plan
details.
2. Description of Structural components associated with a new domestic jetty, including hardwood
component/s certified timber piles, timber framing, Eco5000 Ultralife decking; aluminium handrail.
Clearly describe the extent of work
covered by this certificate, e.g. all Structural components associated with a new timber revetment wall, including
structural aspects of the steel roof concrete encased treated timber posts and sleepers
beams. Excludes:
Methods of construction including temporary bracing and propping
Structural support to proposed swimming pool.
Existing structures on the site
3. Basis of certification AS1170 SAA Loading Code
Detail the basis for giving the
certificate and the extent to which AS1720 Timber Structures
tests, specifications, rules,
standards, codes of practice and other AS2159 Piling Code
publications, were relied upon.
AS 4678 Earth-retaining structures
AS4997 Guidelines for the Design of Maritime Structures
Design Guide 05: Timber service life design (Wood Solutions, 2012)
The Coastal Protection and Management Regulation 2017: relevant Parts and
Schedule 3
4. Reference documentation Long View Consulting Engineers Drawings 20.025 [S001 – S005] – C4
Clearly identify any relevant
documentation, e.g. numbered
(Construction Issue)
structural engineering plans.
LOCAL GOVERNMENT USE ONLY
Date received Reference Number/s
See the original
The page text is free to read. Viewing or downloading an original file needs an account.