Wastewater Report
7.0 Design Drawings level
Inspection Port to be installed
This plan is Site Specific for 411 Black Pinch Rd, Cootharaba. between AES Pipes - see
AES pipe pack sand
Appendix Page 11
under
for installation instructions
12.6m
12m
Inlet
1350mm
Inspection Port
Low Vent
4760mm
300mm
Area A
Ground level
Area B Infiltration Extension Area
12.6m x 3410m x 150mm system sand.
Entire bed base is to be ripped
250mm parallel to AES Pipes
Inspection Port to be installed
Gypsum applied at 1kg / m2.
at furthest point from Influent
Note: See Site Plan for position and orientation. to AES Pipes - see Appendix Page 11
for installation instructions
NOT to Scale
Inspection Port
AES pipe Imported sand (course washed)
150mm
Inspection Port 300mm Backfill with site soil min 150mm cover over sand
IMPORTANT DIRECTION and mound soil over bed to prevent water access.
Do not install from this design until it is
300mm Stamped and Approved by the Local Authority. Natural Ground Level
300mm
Council may make changes to this design as part 150mm approx 6% Inspection Port
8/9 of the approval process. Only install from Stamped
9/9300mm 150mm
Sand Approved Plans and refer to the Approval Permit for 150mm
possible changes. Note: See Site Plan for position and orientation.
AES Sand Coverage Minimums
300mm
300mm
IMPORTANT NOTES PLEASE READ.
1500
RIP PARALLEL TO PIPES 250mm AND GYPSUM 1KG / M2
The installer MUST refer to the Advanced Enviro-Septic Design & Installation
Manual provided. If you do not have a copy of this manual please contact Chankar
Environmental and a copy will be emailed FREE. 1350mm 3410mm Scale 1:25 @ A3
Sections C, D, & E of the Design and Installation Manual are of particular relevance Remove Category 6 soils and replace with Category 5 or better.
when installing an Advanced Enviro-Septic System.
THIS IS NOT A SEPTIC TRENCH AND MUST BE INSTALLED AS PER THE
AES DESIGN AND INSTALLATION MANUAL GUIDELINES. Category 5 soils
Ensure you have the correct sand and all fittings to complete the installation if you
are unsure of anything please contact Chankar Environmental (07) 54 744 055 or
Biowater Designs 54 947 620. Note: Category 5 soils can be obtained from a “Loan Pit” on site and filled with the Category 6 soil excavated from the AES bed..
C Lance Picton 2022 all rights reserved 6/11
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.