Performance outcomes                                Acceptable Outcomes
         3. is designed and orientated to ensure         2. if above ground level—12m² with a minimum
             privacy is maintained between uses.             width of 2.5 metres accessed directly from
                                                             the living spaces.
                                                                                                           Complies:
                                                    OR                                                     All dwellings include private open space areas that
                                                                                                           exceed 25m2 at ground. Only 21 units will include
                                                    AO11.2                                                 first floor balconies as part of their unit design.
                                                    Private open space is provided for each small          These areas are described in detail in Dwg No.
                                                    dwelling at the following rate:                        7186-DA32 within Appendix B.

                                                         1. at ground level—a minimum of 20m² directly
                                                             accessed from living spaces and exclusive
                                                             of clothes drying area; or
                                                         2. if above ground level—9m² with a minimum
                                                             width of 2.5 metres accessed directly from
                                                                                                           Complies:
                                                             the living spaces.
                                                                                                           All Private open space is flat and clear of utilities.

                                                    AO11.3
                                                    Private open space contributing to the above
                                                    calculations has a maximum gradient of 10% (1 in
                                                    10) and is clear of any utilities such as gas, water
                                                    tanks and air conditioning units.
PO12                                                AO12.1                                                 Complies:
Safe vehicular access is provided to and from the   Development does not gain direct access from any       The development gains access from Eumundi
site without adversely impacting on the safety of   road with a legal speed limit of 80 kilometres per     Noosa Rd, which has a design speed of 60 km/h.
the road network.                                   hour or above.
Log in to download the original file

Dual Occupancy and Multi Dwelling Code.pdf · 88 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.