Log in to see the plans as drawn¿ play your part - print on recycled paper 2.5m 2 1.5 1 0.5
Existing gutter to be removed and provide folded Selected floor tiles to be installed over non-shrink grout bedding. Floor
COLORBOND® ULTRA flashing to u/s of tiled edge strip. tiles to be installed with flexible adhesive and provide fall to waste outlet.
Floor to have Emer-proof waterproofing barrier installed to entire floor
and wall junctions in accordance with NCC F1.7.
Stratco Outback® flat COLORBOND® Ultra steel roof panels to
be fixed in accordance with manufacturers specifications.
A B C D E
4 440 1 665 8 300 2 565
Stratco C-Square COLORBOND® ULTRA gutter to match
existing units. Gutter to be installed in accordance with
manufacturers specifications.
5 000
Ceiling
Builder to verify min finished
Stratco aluminium beam to match existing units to be in
ceiling height of 2400mm
accordance with structural engineers design and detail.
75mm shs posts to match existing units. Hot
dip galv. SHS posts to be in accordance with
2 500
2 405
structural engineers design and detail.
240 x 45mm h3 treated dressed hwd seat
415
with 2/140 x 45mm support rails.
50
2 500
Ground floor
15
Under deck storage with 50 x 50mm Knotwood aluminium
175
batten screening with hinged access gates.
600
Timber framed decking to have h4 treated timber structure in
accordance with structural engineers design and detail. Provide
86 x 19mm Boral blackbutt decking (Standard & Better Grade)
with s/s screw fixing to structure. Decking shall be installed in
accordance with Timber Queensland Technical Data Sheet 13.
Concrete block retaining wall to be in accordance with
structural engineers design and detail. Footings and slab
construction shall to be in accordance with engineers design
and detail. Termite barriers to comply with AS 3660.1 Approved A B C D E
'Kordon' termite barriers are required to perimeter and
penetrations of slab to be designed and installed by specialist
approved contractor - guarantees are required by the owner
from the manufacturer / installer of the termite barriers. Provide
moisture barrier (200UM) under slab with 200mm laps.
Securely tape joints. Slab to have fall away from building line.
Section A
A 1:50
/Users/benthornton/Dropbox/My Mac (Bens-iMac)/Documents/Cadfiles/2001 -
Kirkman/Archicad/20092021/2001.pln
sbt designs pty ltd t/a
Skale Building Design project Residence lot no. -- B BA Issue 8/2/22
project number
Mobile: 0412 025 657
for David & Jan Kirkman plan no. -- P1 BA Issue 13/8/21
2001
skale
CD01 Conceptual issue 22/1/20
skale.com.au U2/16 Barbados Court drawn BT drawing number
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at Noosa Sound scale (A2) 1:50 Rev Details Date 3.1 B © Skale Building Design