Attachment 1C - UNITS 04 05 DAVID LOW WAY
Attached to the e-mail RESPONSE to Information Request.
PEREGIAN BEACH VILLAS UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, Sheet Index Layout ID Layout Name Published Sheet Index A.01.1 COVER PAGE A.01.2 GROUND FLOOR A.01.3 FIRST FLOOR A.01.4 ELEVATIONS A.01.5 ELEVATIONS NOTES FOR CONSTRUCTION OF CONCRETE SLAB, FLOOR SYSTEMS, FRAMES & TRUSS'S PLEASE REFER TO HINTON STEEL FRAMES DRAWINGS AREAS GENERAL NOTES GROSS FLOOR AREA CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL UNIT 4: 87m2 SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA. AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS. STANDARDS. UNIT 5: 55 m2 STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND WITH THE B.C.A. REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS SCHEDULES OF FINISHES. ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH DIMENSIONS TAKE PRECEDENCE OVER SCALE. AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND AS3788 & PART 3.72 OF THE BCA AS2208 AND THE DESIGN CONDITIONS AS NOMINATED. DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING Collins Developments DIRECTLY TO THE SUPERINTENDENT. BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING HINTON STEEL FRAMES AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm 16 Computer Road Yatala REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS, THE ENTRY OF MOISTURE INTO THE BUILDING. AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL Gold Coast SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS. REQUIREMENTS qld australia 4207 WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION telephone REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS. 3.8.1 OF THE B.C.A AND AS 3740 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET (617) 3287 3398 facsimilie AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER (617) 3382 7656 FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS email: [email protected] FOR MEMBER SIZES w w w .h i n t o n s t e e l f r a m e s .c o m .a u
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 4 pages
Page 2
GENERAL NOTES
PEREGIAN BEACH VILLAS UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND
SCHEDULES OF FINISHES.
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES
DIRECTLY TO THE SUPERINTENDENT.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.
1,310 1,127 4,698 250 4,905
PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE
WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.
90 1,220 90 1,655 90 3,990 250 3,000 90 1,725 90
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
WITH THE B.C.A.
90 1,655 90 900 1,445 90 1,555 250 1,910 90 1,090 825 90 900
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
Patio
324
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
1.0 x 3.0 AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
Patio THE ENTRY OF MOISTURE INTO THE BUILDING.
1.0 x 4.9
90
1,095
1,095
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION
3.8.1 OF THE B.C.A AND AS 3740
90
90
ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
90
Bedroom AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
STANDARDS.
4.0 x 3.8
3,820
2,480
1,890
1,800
Bed Ens REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
WIR
3,300
3.3 x 3.0 2.5 x 1.7
SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
WC AS3788 & PART 3.72 OF THE BCA
90
90
CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
820
90
SHR W
16
MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
90
Laundry 15
AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
380
T W LINEN under
ROBE T 14 REQUIREMENTS
640
stair 13
90
3,710
12
3,620
Ens SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
11
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
1.7 x 3.6 10 FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
10,210
9 FOR MEMBER SIZES
3,580
8
WC UNIT 5 7 LEGEND
UNIT 4 6
5
A/C AIR CONDITIONING AS SPEC. - INSTALLED
BY CONTRACTOR
4 AP 450 X450 REMOVABLE ACCESS
90
Single Garage 3 PANEL - LOCATION TO BE CONFIRMED ON SITE
6,000
6.0 x 3.0 Single Garage 2 BL CONC. BLOCK WALL TO STRUCTURAL ENG.
2,070
10
12
13
14
15
16
17
11
6,000
DETAIL - RENDER AND PAINT AS SPEC.
9
1
6.0 x 3.3
2,200
CF COLORBOND FLASHING TO DETAIL
1,060
CJ CLADDING CONTROL JOINT - REFER ELEVATIONS
8
7
6
5
4
3
2
1
D-02
CONC CONCRETE SLAB TO ENG. DETAIL
CPD CUPBOARD
300
DP 90mm DIA DOWNPIPE AS SPEC.
REFER TO DETAILS FOR TYPICAL FIXING
90
90
DRY CLOTHES DRYER
Entry DW DISHWASHER
Timber
1,845
EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
2,655
2.6 x 2.1
1,700
fence GUTTER BRACKETS @ MAX 900 CRS
450 90
EGL EXISTING GROUNDLINE
F REFRIGERATOR
90
FW FLOOR WASTE
90
GD S.S GRATED DRAIN AS SPEC.
Patio
1,110
1,000
1,000
HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION
1.3 x 5.3 Timber HP HOT PLATES AS SPEC.
600
HWU HOT WATER
fence MR MECHANICAL RISER
1,110
MW MICROWAVE
NGL NATURAL GROUND LINE
90 1,220 90 2,645 90 3,000 250 3,915 90 900 OV OVEN
P PANTRY
PGL PROPOSED GROUNDLINE
1,310 600 90 2,045 90 3,000 250 3,300 90 1,515 PTF POLISHED TIMBER FLOOR AS SPEC.
RHS RHS TO STRUCTURAL. ENG. DETAIL
RV "WIRILY BIRD" OR SIM. APPROVED
12,290 S SINK
SD HARDWIRED SMOKE DETECTOR TO
COMPLY WITH A.S. 3786-1993
SHR SHOWER TO DETAIL
SHS SHS TO STRUCTURAL. ENG. DETAIL
SL SKYLIGHT AS SPEC.
T TUB
T-1 INTERNAL TILE AS SPEC.
T-2 EXTERNAL TILE AS SPEC.
TD HWD TIMBER DECKING AS SPEC.
TOW TOP OF WALL
VAC IN-BUILT VACUUM SYSTEM AS SPEC.
VB VANITY BASIN
WC TOILET SUITE
WF COLORBOND WALL FLASHING
WM WASHING MACHINE
Amendments Wind Rating Checked By: Status: PR Date: 20.03.14
PEREGIAN BEACH VILLAS
C 11.12.13 Site plan revised + amendments CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
D 16.01.14 Amend GFA CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
E 21.01.14 Client request amendments CT Date:
UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, F 24.01.14 Client request amendments CT
PH: 0410 650 745
GROUND FLOOR
BSB No.: 1043429
G 25.02.14 Amend design CT NOTES: Client: Drawing No.:
ABN: 59 980 573 352
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
H
I
04.03.14 Amend design
20.03.14 Amend design & areas
CT
CT
ECO REMOTE A.01.2 I
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 3
GENERAL NOTES
PEREGIAN BEACH VILLAS UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND
SCHEDULES OF FINISHES.
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES
DIRECTLY TO THE SUPERINTENDENT.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.
PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE
1,310 1,969 90 3,766 250 4,815 90 410 WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
90 1,220 90 5,735 250 3,815 90 1,320 90 WITH THE B.C.A.
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
45
90
104
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
2,104
Outdoor living Outdoor living
THE ENTRY OF MOISTURE INTO THE BUILDING.
2,000
3.0 x 4.7 2.1 x 4.8
2,999
2,954
2,909
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION
3.8.1 OF THE B.C.A AND AS 3740
ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
860
860
AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
Bay Window
STANDARDS.
Living
90
90
REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
2.4 X 3.9
SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
AS3788 & PART 3.72 OF THE BCA
UNIT 5
16
15
CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
Living Dining 14
4,310
4,020
13
3.7 x 3.5 3.3 x 2.3
4,310
3,930 12
MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
11
AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
Deck
9,670
REQUIREMENTS
10
UNIT 4 Kitchen 9
SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
5,910
2.7 x 3.9 8
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
7
FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
6
FOR MEMBER SIZES
5
LEGEND
90
4
90
90
3
Kitchen A/C AIR CONDITIONING AS SPEC. - INSTALLED
2
BY CONTRACTOR
10 2.6 x 3.1
12
13
14
15
16
17
11
1,890
9
1
2,380
AP 450 X450 REMOVABLE ACCESS
PANEL - LOCATION TO BE CONFIRMED ON SITE
8
7
6
5
4
3
2
1
BL CONC. BLOCK WALL TO STRUCTURAL ENG.
3,000
DETAIL - RENDER AND PAINT AS SPEC.
3,000
CF COLORBOND FLASHING TO DETAIL
2.8 x 3
90
90
CJ CLADDING CONTROL JOINT - REFER ELEVATIONS
CONC CONCRETE SLAB TO ENG. DETAIL
CPD CUPBOARD
WC
Study DP 90mm DIA DOWNPIPE AS SPEC.
2,255
2,255
WC
2,035
REFER TO DETAILS FOR TYPICAL FIXING
2.3 x 4.1 DRY CLOTHES DRYER
90
990 90
DW DISHWASHER
990
WC
Balcony EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
GUTTER BRACKETS @ MAX 900 CRS
1,880
EGL EXISTING GROUNDLINE
90
90
Deck 0.9 x 3.4 F REFRIGERATOR
900
FW FLOOR WASTE
GD S.S GRATED DRAIN AS SPEC.
900
900
HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION
90
HP HOT PLATES AS SPEC.
90 HWU HOT WATER
90 1,820 90 1,000 90 4,045 250 1,200 2,615 1,410 MR MECHANICAL RISER
MW MICROWAVE
NGL NATURAL GROUND LINE
1,910 90 1,700 3,435 250 900 90 2,825 90 910 500
OV OVEN
P PANTRY
1,910 5,225 250 1,500 3,315 500 PGL PROPOSED GROUNDLINE
PTF POLISHED TIMBER FLOOR AS SPEC.
RHS RHS TO STRUCTURAL. ENG. DETAIL
RV "WIRILY BIRD" OR SIM. APPROVED
S SINK
SD HARDWIRED SMOKE DETECTOR TO
COMPLY WITH A.S. 3786-1993
SHR SHOWER TO DETAIL
SHS SHS TO STRUCTURAL. ENG. DETAIL
SL SKYLIGHT AS SPEC.
T TUB
T-1 INTERNAL TILE AS SPEC.
T-2 EXTERNAL TILE AS SPEC.
TD HWD TIMBER DECKING AS SPEC.
TOW TOP OF WALL
VAC IN-BUILT VACUUM SYSTEM AS SPEC.
VB VANITY BASIN
WC TOILET SUITE
WF COLORBOND WALL FLASHING
WM WASHING MACHINE
Amendments Wind Rating Checked By: Status: PR Date: 20.03.14
PEREGIAN BEACH VILLAS
C 11.12.13 Site plan revised + amendments CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
D 16.01.14 Amend GFA CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
E 21.01.14 Client request amendments CT Date:
UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, F 24.01.14 Client request amendments CT
PH: 0410 650 745
FIRST FLOOR
BSB No.: 1043429
G 25.02.14 Amend design CT NOTES: Client: Drawing No.:
ABN: 59 980 573 352
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
H
I
04.03.14 Amend design
20.03.14 Amend design & areas
CT
CT
ECO REMOTE A.01.3 I
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 4
ELEVATION LEGEND
PEREGIAN BEACH VILLAS UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D-0
WD-0
DOOR NUMBER
WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
AC AIR-CONDITIONING
Rendered fire rated wall in ALY ALYSNITE FLAT SHEETING
accordance with BLK BLOCKWORK
manufacturers specifications CN CONCRETE
DP1 90Ø DOWNPIPE
Roof sheets @ 70 pitch fixed EG1 EAVES GUTTER
in accordance with FC FIBRE CEMENT WITH 10mm EXPRESSED
manufactures specification Specified cladding fixed in JOINTS
accordance with manufactures FCC COMPRESSED FIBRE CEMENT
specification FL FLASHING
Ceiling Level Ceiling Level LVF FIXED ALUMINIUM LOUVRE
MRS METAL ROOF SHEETING
Exposed rafters to roof system ZINC ZINC CLADDING WITH STANDING SEAM
NGL NATURAL GROUND LINE
PLY PLYWOOD WITH 10mm EXPRESSED
2,740
2,740
JOINTS
SPR SPREADER
Glass Ballustrade in
7,661
SPT SPITTER
accordance with BCA & Aus Timber screen to juliet style balcony
Standards
Floor Level Floor Level
Specified cladding fixed in Ceiling Level
Ceiling Level
accordance with manufactures
Aluminium framed windows specification
fixed to manufactures
specifications
2,740
2,740
Entrance gate, in accordance
Steel beams in accordance with owners specifications
to engineers specifications
21 - 24 roller door 21 - 27 roller door
Slab Level NGL NGL Slab Level
1 Front Elevation 1:100
Aluminium framed windows and
Roof sheets @ 70 pitch fixed
sliding doors fixed to manufactures
in accordance with
specifications
manufactures specification
Roof sheets @ 70 pitch fixed
0
Roof sheets @ 7 pitch fixed in accordance with
in accordance with manufactures specification
manufactures specification
Bay window, with specified cladding
Ceiling Level fixed in accordance with Ceiling Level
manufactures specification
Steel column in accordance with
manufacturers specifications
2,740
2,740
Timber screen Ballustrade to be installed in
accordance with BCA and Aus
Floor Level standards Floor Level
Ceiling Level Ceiling Level
Specified cladding fixed in
Specified cladding fixed in accordance with manufactures
accordance with manufactures specification
2,740
2,740
specification
Rendered fire rated wall in
accordance with
manufacturers specifications
Slab Level NGL NGL Slab Level
2 Right 1 Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 20.03.14
PEREGIAN BEACH VILLAS
C 11.12.13 Site plan revised + amendments CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
D 16.01.14 Amend GFA CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
E 21.01.14 Client request amendments CT Date:
UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, F 24.01.14 Client request amendments CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
G 25.02.14 Amend design CT NOTES: Client: Drawing No.:
ABN: 59 980 573 352
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
H
I
04.03.14 Amend design
20.03.14 Amend design & areas
CT
CT
ECO REMOTE A.01.4 I
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 5
ELEVATION LEGEND
PEREGIAN BEACH VILLAS UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D-0
WD-0
DOOR NUMBER
WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
Rendered fire rated wall in Roof sheets @ 70 pitch fixed
accordance with in accordance with AC AIR-CONDITIONING
manufacturers specifications manufactures specification ALY ALYSNITE FLAT SHEETING
BLK BLOCKWORK
CN CONCRETE
DP1 90Ø DOWNPIPE
Exposed rafters to roof system
EG1 EAVES GUTTER
FC FIBRE CEMENT WITH 10mm EXPRESSED
JOINTS
Bay window, with specified cladding FCC COMPRESSED FIBRE CEMENT
Ceiling Level fixed in accordance with Steel Column to engineers Ceiling Level FL FLASHING
manufactures specification specification LVF FIXED ALUMINIUM LOUVRE
MRS METAL ROOF SHEETING
Aluminium framed bifold ZINC ZINC CLADDING WITH STANDING SEAM
Aluminium framed bifold windows NGL NATURAL GROUND LINE
beyond fixed to manufactures windows fixed to manufactures
2,740
2,740
PLY PLYWOOD WITH 10mm EXPRESSED
specifications specifications JOINTS
SPR SPREADER
Ballustrade, in accordance Ballustrade to be installed in SPT SPITTER
with the BCA and relevant Aus accordance with BCA and Aus
Floor Level Standards standards Floor Level
Ceiling Level Ceiling Level
Aluminium framed windows and Specified cladding, to be
sliding doors fixed to manufactures installed in accordance with
manufacturers specifications
2,740
2,740
specifications
Timber fence Timber fence
Slab Level Slab Level
NGL NGL
3 Rear Elevation 1:100
Aluminium screen, in
accordance with manufacteres
specifications Roof sheets @ 70 pitch fixed
in accordance with
Roof sheets @ 70 pitch fixed manufactures specification
in accordance with
manufactures specification
Roof sheets @ 70 pitch fixed
in accordance with
Ceiling Level
manufactures specification Ceiling Level
Exposed rafters to roof system
Rendered fire rated parti wall in accordance Fire rated parti wall beyond in
with engineers specifications accordance with engineers
specifications
2,740
2,740
Steel column in accordance with engineers
specifications
Glass Ballustrade to be installed in Timber screen
accordance with BCA and Aus standards
Floor Level Floor Level
Ceiling Level Ceiling Level
Specified cladding fixed in
accordance with manufactures
2,740
2,740
Specified cladding fixed in accordance with specification
manufactures specification
Aluminium framed windows and
sliding doors fixed to manufactures
Slab Level specifications Slab Level
NGL NGL
4 Left Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 20.03.14
PEREGIAN BEACH VILLAS
C 11.12.13 Site plan revised + amendments CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
D 16.01.14 Amend GFA CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
E 21.01.14 Client request amendments CT Date:
UNIT 4 & 5, 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, F 24.01.14 Client request amendments CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
G 25.02.14 Amend design CT NOTES: Client: Drawing No.:
ABN: 59 980 573 352
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
H
I
04.03.14 Amend design
20.03.14 Amend design & areas
CT
CT
ECO REMOTE A.01.5 I