24.007_The Peninsula_Issue C_20Jun24
drawing index
01 SITE PLAN
02 FLOOR PLAN, FLOOR FRAMING PLAN & TYPICAL SECTION
Project: NEW JETTY
Client: ANDREW & AMY PURSELL
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551
Address: No. 43 THE PENINSULA, NOOSAVILLE Q 4566 0409 612 231 | [email protected]
WWW.KUNKELBUILDINGDESIGN.COM.AU
QBCC Lic No 1136721
Lot 279 ON RP856192 DRAWING NAME REV DATE
COVER SHEET C 20/06/24
A3
DESIGNER PROJECT NO
SD KUNKEL 24.007
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
2. Extent of site earthworks to be confirmed by
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
41.700m 44°19'45" Projected boundary 4. All services to be located on site by contractor prior
peninsula
wall to c
to construction.
oundary
5107 fro of jetty at reve
4.709
9924 - b 5. Do not scale off drawings, use figured dimensions
entre
m
4170
only. Any dimensions not nominated must be referred to
m screw
10260
9
the
114°4
.867m
the Designer for confirmation. Contractor shall verify all
dimensions on site prior to construction.
in invetm ent wall
5'0
property details
"
tm
10420
No. 43 The Peninsula
ent
"
45'0
Noosaville QLD 4566
300°40'5
159°
Noosa Shire Council
0m
Locality - Noosaville
9.0m x 3.5m seapen
7000
0"
5.00
Lot 279 on RP856192
boat storage device
Site Area - 1004m²
Zone - Low Density Residential
Precinct - N/A
Overlays - Acid Sulphate Soils
11.868m
9170 - Flood Hazard Extents
8874 - boundary
proposed
jettys
canal
313°32'10"
49.0
12m
5"
326°23'2
77°
31'1
0"
Existing revetment wall
08
224
11.868m
339° 1m
"
15'0
3.00
Pro
ject
ed b
oun
dar
y signatures
owner/s
site plan
1 1 : 200
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
NORTH SDK SDK N3 ANDREW & AMY PURSELL NEW JETTY
No. 43 THE PENINSULA, NOOSAVILLE Q 4566
SITE PLAN 01
SHEETS IN SET
C 24.007
SCALE
A3
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
C 20/06/24 SDK CONSTRUCTION ISSUE Lot 279 ON RP856192 2 1 : 200
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
Page 3
Bounda
Bounda
aluminium framing sizes to engineers
ry
ry
10260 design & detail
1500 8760 1160 2800 2800 2800 700
1500l x 400w 1500l x 400w
400
kayak steps kayak steps
750
jetty
1500
750
850
9950
200x50x3mm aluminium
9.0m x 3.5m seapen floor joists @ 450mm crs max.
4000
7800
4000
boat storage device Composite decking over
2/152x62x8mm structural
9330 280mm deep fascia
'c' channel headstocks per pile
980
Existing revetment wall
750
Do not fix jettys Do not fix jettys
jetty
1500
to revetment wall to revetment wall
750
400
315 dia. pvc insitu piles
1500 7670 Existing revetment wall 820 2550 2550 2550 700 to engineers detail
9170
Joists to butt into headstocks
with site welded connection
floor plan floor framing & footing plan
1 1 : 100
2 1 : 100
notes
1. Contractor to confirm exact siting and orientation
prior to construction setout.
2. All building setout & confirmation of setbacks &
height to be carried out by a Licensed Surveyor.
Boundary line
3. Do not scale off drawings, use figured dimensions
only. Any dimensions not nominated must be referred to
200x50x3mm aluminium the Designer for confirmation. Contractor shall verify all
floor joists @ 450 crs max. dimensions on site prior to construction.
- composite decking over 4. Levels & services locations to be confirmed prior to
Do not fix jetty to Floor joists site welded to construction.
revetment wall headstocks to engineers detail 2/152x62x8mm structural
'c' channel headstocks per pile 5. Termite protection to be provided in accordance with
clause 3.1.4 of the BCA (QLD variation) & AS3660.1.
280mm deep composite decking Contractor to provide protection information for building
development application.
fascia to perimeter
legend
Existing revetment wall
Headstocks to piles to Denotes dimension to centre line
engineers detail
Denotes dimension to outside face
315 dia. pvc insitu piles
floor areas
to engineers details
jetty area 29.0 m²
section total area 29.0 m²
4 1 : 50 signatures
owner/s
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
NORTH SDK SDK N3 ANDREW & AMY PURSELL NEW JETTY
No. 43 THE PENINSULA, NOOSAVILLE Q 4566
FLOOR PLAN, FLOOR FRAMING PLAN &
TYPICAL SECTION
02
SHEETS IN SET
C 24.007
SCALE
A3
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
C 20/06/24 SDK CONSTRUCTION ISSUE Lot 279 ON RP856192 2 As indicated
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies