P RR
5-43 5-40 SHR TE 02
ROBE C C ROBE ROBE C C ROBE C C ROBE C C ROBE RAKING
D D
W 5-39 RA
5-14 D D 5-44 D D D D W KI
NG
5-51 5-45 5-38 5-32 5-26 5-20 5-04
RW + CTR 50
RW + CTR 50
RW + CTR 50
RW + CTR 50
FRL 90/90/90
FRL 90/90/90
FRL 90/90/90
5D BED 2 BED 3 BED 1 BED 2 MEDIA BED 2 MEDIA BED 3 BED 2 5D
ROBE
BATTER
1890
D
5-16
D D D D
BA
5E 5-15 5-17 5-18 5-19 5E
TT
W W W W S-1.2 W W W W W
ER
5-13 5-12 5-11 5-10 5-09 5-08 5-07 5-06 5-05
TERRACE WALKWAY TERRACE
2450
FALL D D D D FALL
FALL
FALL
5-13 5-12 5-09 5-08
FALL
02 02
14.420m UP 1:20
FALL
FALL FALL
CL
05
07-05
DP FE H
S-1.1
E FE DP
CL FLOOR PLAN LEGEND
HR01 HC HR01 HR01
STAIR
RAK
05 D D
5F 04 5-14
16
5-07 5F
05-05 15
HR07
SCR08 DP SCR08
ING
03 D 14 AWN1 AWNING
5 RISERS 02 DP 5-14 13 DP
@ 190mm 01 SCR04 SCR04 SCR04 BG BOX GUTTER
RAKING
UP 12
UP 18 HR01 LIFT 17 UP BO 1200 HIGH BOLLARD (FINISH TO
RAKING
11
RL 15.250 STAIR 01 17
05 10 STAIR 16 01
SPECIFICATION)
F02 DP STAIR
VOID
VOID
3790
02 16 15 02
HR06
HR04
HR04
HR06
05-01 03 15
09
05-04 14 03 BR BIKE RACK
04 14
H 08
07
H
13 04 05-02 BTFW BUCKET TRAP FLOOR WASTE
RA 17 RISERS 05 13 16 RISERS 12 05
HR KIN 06 @ 186mm 11 06 C CUPBOARD (REFER TO INTERIOR DETAILS)
04 G @ 181mm BATTER BATTER HR04 BATTER 17 RISERS CJ CONTROL JOINT
@ 180mm
CON. TROWEL FINISHED CONCRETE
07 08 0911 12 10 09 08 07
D DUCT
RAK 5G 5G DP DOWN PIPE
IS
ING
TG
DW DISHWASHER UNDER
STA
RAK
RL 14.530 D
05- IR F02 RL 14.530 00 DOOR NUMBER
ING
18 03 8.8m RAMP UP 1:20
OUTLINEOF PATH BELOW
@ RISE
186 R S DR DRAIN
mm
ECR ENTRY CARD READER
F02
FE FIRE EXTINGUISHER
501 502 503 504 505 506 FHR FIRE HOSE REEL
FRL FIRE RESISTANCE LEVEL
FW FLOOR WASTE
GT GRATED TRENCH
H FIRE HYDRANT
HC HOSE COCK
HR HANDRAIL
HP HYDRAULIC PIPES
RA
KIN
G
HWU HOT WATER UNIT
MR MECHANICAL RISER
MW MICROWAVE
NBN NBN BOARD
P / PTY PANTRY
PO PLANTER OUTLET
R REFRIGERATOR SPACE (-INT = INTEGRATED)
RO ROOF OUTLET
RL 0.00 REDUCED LEVEL
SB SWITCH BOARD
G
SCR SCREEN
KIN SC STRUCTURAL COLUMN
RA RA
KIN
G SDO SPOON DRAIN OUTLET
S-B.1 SIGN NUMBER - REFER TO DRAWING A13-01
SF SECURITY FENCE
01 FLOOR PLAN RAKING
SHR
SHR BATH
SHOWER
SHOWER OVER BATH
- BLOCK 5 - LEVEL 1 SCALE 1:100
RAKING
SM
SP
SMOKE SEALS TO DOOR FRAME
SPITTER
SFL 0.00 STRUCTURAL FLOOR LEVEL
WM WASHING MACHINE
W WINDOW NUMBER
00
NOTE :
REFER TO ENGINEER'S DRAWINGS FOR STRUCTURAL DETAILS
PROPOSED PRECINCT F DEVELOPMENT, ALTUM CONSTRUCTIONS Development Approval north
scale: 1:100
issue: 02 date: 09-10-18
NOOSA SPRINGS
Document Set ID: 21147047
BLOCK 5 - LEVEL 1 7038_DA70_02 The designs, drawings and specification are copyright and always remain the property of Blackburne Jackson Design Pty Ltd.
Version: 2, Version Date: 19/06/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Compiled Approved Plans - 132005 1133 15Related documentApplication case desk ↗
About this file
- File size
- 107 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.