Council archive · source document
Compiled Approved Plans - 132005 1133 15 · 132005.1133.15
Plans and drawings: the text below has words only, no drawings.
Very large file (107 MB): may take a few minutes to open.
Original PDF page 52, section 2. The text section number identifies this passage in the reader.
WASTE
GT GRATED TRENCH
H FIRE HYDRANT
HC HOSE COCK
HR HANDRAIL
A B HP HYDRAULIC PIPES
05-01 05-01 HWU HOT WATER UNIT
9140 7800 7800 5850 MR MECHANICAL RISER
MW MICROWAVE
NBN NBN BOARD
P / PTY PANTRY
301 302 303 304 305 PO PLANTER OUTLET
R REFRIGERATOR SPACE (-INT = INTEGRATED)
RO ROOF OUTLET
RL 0.00 REDUCED LEVEL
SB SWITCH BOARD
SCR SCREEN
SC STRUCTURAL COLUMN
SDO SPOON DRAIN OUTLET
S-B.1 SIGN NUMBER - REFER TO DRAWING A13-01
01 FLOOR PLAN SF SECURITY FENCE
- BLOCK 3 - LEVEL 1 SCALE 1:100 SHR SHOWER
SHR BATH SHOWER OVER BATH
BUSHFIRE PROTECTION NOTE SM SMOKE SEALS TO DOOR FRAME
SP SPITTER
BAL 12.5 MINIMUM CONSTRUCTION IN SFL 0.00 STRUCTURAL FLOOR LEVEL
ACCORDANCE WITH AS3959-2009 AND WM WASHING MACHINE
AMENDMENTS. W WINDOW NUMBER
00
REFER TO CONSTRUCTION NOTES, DOOR AND NOTE :
WINDOW SCHEDULES, SCHEDULE OF FIXTURES REFER TO ENGINEER'S DRAWINGS FOR STRUCTURAL DETAILS
AND FINISHES & SPECIFICATION
TENDER ISSUE
NOT FOR CONSTRUCTION
CHECKED : .............................................
notes : issue amendment log by date issue amendment log by date consultants: project: north
A BUILDING APPROVAL KU 02-08-17 K FOR CONSTRUCTION, BUSHFIRE KU 30-07-18
date: 2017
1 The designs, drawings and specification are B COORDINATION ISSUE MF 14-08-17 L VALUE MANAGEMENT, ADDED HOSE COCKS KU 05-09-18 PROPOSED PRECINCT F DEVELOPMENT,
copyright and always remain the property of C BUILDING APPROVAL KU 18-08-17 NOOSA SPRINGS drawn: KU
Blackburne Jackson Design Pty Ltd. D COORDINATION ISSUE KU 08-09-17
E REVISED ISSUE MF 03-10-17 B la ck b u rn e J a ck s o n D e s i gn checked: SC
2 Before commencing construction: F COORDINATION ISSUE KU 23-11-17 Archi tec t ure Landscape I n t e r i or s client:
- Verify all dimensions and levels. TGIF EXTENDED, STRUCTURAL COORDINATION,
- Verify location and levels of all services on site.
G ADDED NOTES, MICROWAVE LOCATION SHOWN KU 10-01-18 ALTUM CONSTRUCTIONS scale: 1:100
- Verify that floor levels and finished levels will H TOW's ADDED MF 20-03-18 title:
37 Aerodrome Rd Maroochydore Qld
enable connection to services. LANDSCAPE COORDINATION ISSUE, T.O.W.'S project/drawing no.
I AMENDED MF 23-03-18 P.O. Box 154 Cotton Tree Qld 4558
email [email protected]
phone
fax
07 5443 3200
07 5443 4030
BLOCK 3 LEVEL 1 - sheet: A1
3 Do not scale this drawing.
When in doubt refer to Architects. J
TENDER ISSUE, HANDRAIL EDITS, LEGEND
UPDATE, STAIR EDITS, WINDOW SCHEDULES
UPDATED, SIGNAGE ADDED
KU 11-02-18
FLOOR PLAN 7098_A02-02_L
7088-18-CTS 3 printed: Tuesday, 9 October 2018 2:05 PM
Document Set ID: 21147047
Version: 2, Version Date: 19/06/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Compiled Approved Plans - 132005 1133 15Related documentApplication case desk ↗
About this file
- File size
- 107 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.