WO oW^ [^z Shell Rebrand 7m Pylon HEX 001:A
engineered solutions Region A and B - TC: 3 01-Dec-07 (^.
Wind Loads:
Param. Formula Value Units
Reg Region. B
TC Terrain Category 3.0 ••
hz Height top of sign above NGL. 7.00 m
ho Height to datum 000 m
h Height top of sign above datum = hz - ho 7 00 m
R Recurrance Interval 50 '•
VR Regional wind speed 44 m/s
pz Wind pressure at height z = hz 0.72 kPa
c Height of sign face (vertical) 7.00 m
b Length of sign face (horizontal) 2.01 m
b/c Ratio. length to height. 0.29
c/h Ratio height to total height 1.00 •'
Cp Wind pressure coefficient 1 32 •'
po Design wind pressure 0 95 kPa
As Area sign face 14.07 mA2
hcoa Vert disn to centre of area 3.50 m
ea Honz disn CL to CoA 0 00 m
e Design eccentricity = 0.2•b 0 40 m
et ea+e 0.40 m
Ws Wind load 13 41 kN
Ms Wind moment 46 95 kNm
n. Number of vert supports 2 ••
b. Honz disn supports CL to CL 1.80 m
Wind (® 90 to sign face (e = 0)
Wv9o Max wind load on vert support 6.71 kN
Mv90 Max wind mnt on vert support 23.48 kNm
Wind @ 45 to sign face (e = 0.2b)
M45 Eccen multipier = (bv + 2*et)/(2*bv) 0 72
Wv45 Max wind load on vert support 9 70 kN
Mv45 Max mnt on vert support 33 96 kNm
Vertical Member => 200x1 00x6.0 RHS (C350) rpMsx = 66.20 kNm
4 Vvx = 406.00 kN
mxMx/4PMsx 071 <10
vx = Vvx / (PVvx = 0.05 < 1.0
(mx)2 + (vx)2 = 0.51 < 1.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
OPW11/0034 Development Application part 2 of 2Related documentApplication case desk ↗
About this file
- File size
- 1.8 MB (small file)
- File type
No other editions are linked here.