RFI - Klaus Vario Product Data
Loading schedule
The systems are dowelled into the ground. The drill hole depth in the floor plate is approx. 15 cm, in the walls approx. 12 cm.
The floor plate and walls must be from concrete (quality min. C20/25).
The dimensions for the bearing points have been rounded. If the precise figures are required, please consult KLAUS Multiparking.
Column bases can be variably selected (short or long configuration). Always observe the corresponding forces.
Variant 1 (V1): short column bases
Variant 2 (V2): long column bases
Parking space load F1 F2 F3 F4
2000 kg + 30.0 kN + 1.1 kN - 7.4 kN ± 1.0 kN
V1
2600 kg + 36.0 kN + 1.4 kN + 9.3 kN ± 1.0 kN
2000 kg + 30.0 kN + 0.5 kN + 7.7 kN ± 1.0 kN
V2
2600 kg + 36.0 kN + 0.7 kN + 9.8 kN ± 1.0 kN
1 Width dimension B1 (see "Width dimension without door", page 6)
2 The system must be supported on both sides. An additional stand may be installed if there are no walls at the sides. A floor area of 50 x 30 cm is
required for these stands (concrete quality min. C20/25, drill hole depth approx. 15 cm).
3 Marking in accordance with DIN ISO 3864 (illustration colour not consistent with DIN ISO 3864)
Product data SingleVario 2061 584.69.890-012 04/2023 English 7