NOTE - PROVIDE INTERMEDIATE CEILING BATTENS

125 X 5O (F14) RAFTERS
AT 900 CENTRES

~~

~~
~~

~~
ee
~~.

GAL DIAGONAL CROSS BRACING TO BE
PROVIDED TO RAFTERED ROOF

. 265 X 6B HYNEBEAM 17 €

LIVING ROOM

PART WALL TO BE REMOVED. | | EXTENSION

2400

TIMBER

EW T&
O MATCH EXISTING

N G
FLOOR TO M.

PROVIDE R 3 BLANKET INSULATION TO ROOF AREA

5.0° ROOF PITCH
~~, — SSS
~~ —

  

2195

COLORBOND METAL ROOFING ON

a

J

      

 

| 600 | PLASTERBOARD INTERNAL WALL AND CEILING LININGS \.

90 mm STUD WALL \
RAILING

\

TIMBER HAND RAILS AND BALLUSTRADES

9
9
Q TO COMPLY WITH AUST BUIDING CODE 3.9.2

METAL ROOFING BATTENS AT 900 CENTRES

PREFABRICATED TIMBER ROOF
TRUSSES AT 900 CENTRES

a
25,0° ROOF PITCH

  

 

 

ka 4

 

 

 

 

 

 

130 X 65 HYNE lo
FLOOR JOIST AT |

450 CRS - CANTILEVERED.
MAX 800 mm

FLOOR TO MATCH EXISTING

t
NEW COMPRESSED BOARD |

TT

ly SIE HW DECKING

jf 200, 175 X 50 (F14) ROOF BEAMS
MAX SPAN 2200

EXTERNAL CLADDING "SHADOW LINE" PANEL BOARD
EXTERNAL WALL BOARDS WITH REFLECTIVE FOIL
INSULATION UNDER.

2400

CONCRETE FLOOR TO
900 ABOVE GL

 

FIBRO-CEMENT SHEET couna

   
 

A
100 X 100 HW POSTS

PROPOSED CARPORT

 

CONCRETE FLOOR

 

 

 

 

300

BLOCK RETAINING WALL TO
STRUCTURAL ENGINEERS SPECIFICATIONS

 

 

SECTION A-A

 

TIE DOWN REQUIREMENTS -

ROOF BATTENS
METAL BATTENS TO MANUFACTURERS SPECIFICATIONS.

+ RAFTERS/TRUSSES

BO X 0.8 mm G.t. STRAPS
4/2.8 DIA NAILS EACH LEG.

TOP PLATES
12 mm DIA BOLTS WHERE INDICATED
ON BRACING PLAN. (50 X 50 X 3 mm WASHERS)
TIE DOWN AT 1800 MAX CENTRES
LAMINATED BEAMS.
12 mm DIA BOLTS EACH END.
VERANDAH PLATE
2/ Mi2 BOLTS.

 

75 X 75 GAL STEEL STUMPS

 

——

SECTION B-B

 

ALL EXTERNAL WALL STUDS

 

DESIGNED FOR WIND CLASSIFICATION N32 (REGION B) |

 

ALL CONSTRUCTION TO COMPLY WITH AS 1684 -1999 NOT NOTCHED.

AND THE BUILDING CODE OF AUSTRALIA.

 

RETAINING WALLS
CONCRETE FLOOR AND FOOTINGS
TO STRUCTRAL ENGINEERING DETAIL

WALL STUDS 90 X 35 (MGP 10 AT 450 CENTRES

TOP PLATES (UPPER FLOOR) 2/35 X 90 (MGP 10) % 2p ~ ey
BOTOM PLATES (UPPER FLOOR) 35 X 90 (MGP 10) oe o veap
3, EXO
Go AZ
2

(SUBJECT TO SOIL TEST)

 

 

 

   

SEE SUB FLO .
; FOR BEARERS A\ EJOISTS

 

r Co
_LINTEL AND JAMB SD SIZES
| SEE BRACING PLA SHEETS 9 & 1¢

 

 

 

 

 

BRIAN HILDEBRAND DRAFTING : PROPOSED EXTENSIONS FOR

contractor must verify all dimensions

on site before commencing work do not scale any dimensions

 

date 18 FEB 2008

 

 

184 GUMBOIL ROAD
TINBEERWAH _ DJONES & D CLELLAND
phone/fax 07 5447 7784 _ ATNo 575 BLACK MOUNTAIN ROAD
QBSANo 78055 | BLACK MOUNTAIN

t

DRAWING No 20708 - 22
sheet 5 of ll scale 1 = 50

 

 

 

 

4

 

 

 

Used in these records

About this file

File size
2.6 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

20080490 - Decision Notice [As Published].pdf · 2.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.