GENERAL NOTES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

            

 

 

      
    

      

 

           

 

 

  

       
           

   

  

      

     

  

 

 

 

 

 

 

 

 

 

 

 

a GROSS FLOOR AREA SITE COVER BCA PART 3.12.1 ENERGY EFFICIENCY
4. ALL WORKMANSHIP SHALL BE CARRIED OUT TO THE BEST TRADE THERMAL INSULATION
STANDARDS AND MATERIAL FIXED IN ACCORDANCE WITH ACTUAL : . JACTUAL| max
SPECIFIED DETAIL AND MANUFACTURER'S RECOMMENDATIONS. Name | Area | GFA | MAX GFA |complies SITE | %site | permissible ALL WALLS AND ROOF TO COMPLY WITH THE BCA REQUIREMENTS
Name | Area | AREA| cover cover complies FOR THERMAL EFFICIENCY.
2. THE FOLLOWING DOCUMENTS FORM PART OF THE -
DOCUMENTATION FOR THIS PROJECT: MBER FRAMED unit 1 59.45 | 11.09% 0.00% Gant 10574 536221 187% 50% 7 FOR CLIMATE ZONE 2, ALTITUDE LESS THAN 300m:
We E ; a ni a . . fo fo es
CONSTRUCTION CODE unit 1 64.18 _[11.41% 7 9 9 ROOF CONSTRUCTION TOTAL R-VALUE: MIN 2.7
unit 1 120.63 22.5% 0.00% Unit 2_ |101.78 |536.22 | 18.98% 20% Yes BULK INSULATION TO ROOF SPACE MIN R-VALUE 23
3. THE ABOVE DOCUMENTS SHOULD BE KEPT ON SITE DURING 9 Grand total 38.70% 40%
UNIT 2 67.62 |12.61%
CONSTRUCTION ALONG WITH THE COPY OF THE LOCAL APPROVED : : WALL CONSTRUCTION TOTAL R-VALUE: MIN 1.9
PLANS AND SPECIFICATIONS. CONSTRUCTION MUST NOT VARY UNIT 2 53.53 [9.98% 45.10% |Yes a) TIMBER FRAMED CONSTRUCTION: BULK WALL
FROM THE ABOVE DOCUMENTATION WITHOUT WRITTEN APPROVAL 3) INSULATION MIN R-VALUE 1.5 -
FROM THE OWNER AND THE LOCAL AUTHORITY. UNIT 2 121.15 22.59% 45.10% . b) BLOCKWORK OR BRICK VENEER CONSTRUCTION: BULK
Grand total 241.78 45.09% 45.10% WALL INSULATION MIN R-VALUE 1.37
4, FIGURED DIMENSIONS TAKE PRECEDENCE OVER SCALING OFF
PLAN. DO NOT SCALE. ANY DISCREPANCIES FOUND BUT THE
BUILDER / OWNER SHOULD BE BROUGHT TO THE ATTENTION OT
THE DESIGNER PRIOR TO CONSTRUCTION OR FABRICATION OF SOFT LANDSCAPED AREA QUEENSLAND DEVELOPMENT CODE
ANY ITEM.
SIE 1% SOFT LANDSCAPED MP 4.1 - SUSTAINABLE BUILDINGS
§. RETAIN ALL EXISTING VEGETATION AND MATURE TREES WHERE Name AREA | AREA AREA REQUIRED] COMPLIES WATER CONSERVATION:
POSSIBLE, : 1. WATER SAVING SHOWER ROSES TO BE INSTALLED.
EITHER AAA RATING (ASSESSED AGAINST AS/NZ 6400-2004)
6. STRUCTURE SHALL NOT EXCEED 8.4m ABOVE NATURAL GROUND. [LANDSCAPING | 158.98 | 536.22 | 29.65% [20.00% [Yes] OR 3 STAR RATING UNDER WELS, :
2. ALL TOILETS TO HAVE DUAL FLUSH CAPABILITIES THAT DO NOT
7. CHECK ALL DIMENSIONS OF WORKS ON SITE PRIOR TO EXCEED 6 LITRES ON FULL FLUSH AND 3 LITRES ON HALF FLUSH.
COMMENCEMENT OF CONSTRUCTION OR FABRICATION OF ANY 3, MIN $000 LITRE RAIN WATER TANK TO BE INSTALLED TO QDC
ITEM, REFER DISCREPANCIES TO DESIGNER BEFORE REQM'S, CONNECT ALL TOILET CISTERNS AND WASHING MACHINE
CONSTRUCTION OR FABRICATION. COLD WATER SUPPLY TO WATER TANK,
8. COMPLY WITH THE BUILDING CODE OF AUSTRALIA (BCA), 133° 00' 00" ENERGY EFFICIENT LIGHTING:
RELEVANT AUSTRALIAN STANDARDS AND LOCAL COUNCIL BUILDING eee eee eee eee ee _—- ee ee FLUORESCENT LIGHTING TO BE USED IN AT LEAST 40% OF TOTAL
CODES. 35.540 m oo FLOOR AREA.
| . VISITOR
9, REINF, CONCRETE CROSSOVER TO STREET TO BE IN ft LOT 289 (No. 1 7) PARKING |! HOT WATER SUPPLY:
ACCORDANCE WITH THE LOCAL AUTHORITIES DETAILS AND | | = ot el HOT WATER SYSTEM TO BE EITHER
SPECIFICATION. ' U NIT 4 Lu a) HEAT PUMP SYSTEM
oS Ww b) SOLAR SYSTEM
40. TV ANTENNAE LOCATION TO BE VERIFIED ON SITE BY 4711 no 112 oO c) 5 STAR GAS SYSTEM
INSTALLER = — =
SITE NOTES pooem™e AU t ”
DRAINAGE: ‘ ‘ : 4 = 47 FERGUSON STREET, SUNSHINE BEACH
ALL HOUSEHOLD SEWERAGE AND WASTE TO BE DISCHARGED TO eee et -|--— . oO ‘
SEWER SYSTEM. ce on” Details Property Number: 22243
TERRACE NEW s Legal Description: LOT: 0 BUP: 5732
SEWER LINE LOCATION TO BE VERIFIED ON SITE AND NO PART OF ; Site Area: 0.0536 H
THE PROPOSED RESIDENCE TO BE WITHIN 1500mm OF EDGE OF - DRIVEWAY . ©
SEWER PIPE : . woe,
Sle | . ul Status Division: 11
‘ © Bh cee LL Owners —_ Body Corporate - Tanoa
SURFACE WATER: 8 POOL
SURFACE WATER TO BE DISCHARGED BY NATURAL FALL OF THE to _ lo Locality  Eastem Beaches
GROUND AND CUTOFF DRAINS. % © , 313° 00" Zones al irre m
ALL RAINWATER FROM ROOF DISCHARGE SHALL BE DRAINED AT Y Overlays No overtays found for this property.
LEAST 3.0m FROM THE BUILDING FOUNDATION, OR TO LOCAL . “~~ "35540
AUTHORITY REQUIREMENTS, . m LOT NUMBER : 289 (No. 17)
ED PLAN: RP 48111
STORMWATER DRAINAGE NOTES ON Sr Wye
COUNTY OF MARCH
1. DP - 90mm DIA DOWNPIPES TO STORMWATER PIPES 100mm MIN
COVER. 1 IN 100 MIN FALL. LAND AREA : 536.2 sq.m.
2. ONE DOWNPIPE PER 12m OF GUTTER, REDUCE BY 1mFOR
EACH BEND IN GUTTER.
3, STORMWATER PIPES SHALL BE CONNECTED TO KERB AND
CHANNEL TO LOCAL AUTHORITY REQUIREMENTS. SITE PLAN
1: 200
FOR APPROVAL A3
REV [DATE | DESCRIPTION SPECIFICATION NOTES TRANG TE
Tmrnomccrnonrccecosas | DUPLEX ALTERATIONS SITE PLAN
ae rose no On STE BEFORE soul Sspace Unique Designer Homes by Paul Hindes SOME PROKCT No
COMMENCING FABRICATION Ph {0775455 3694 | Fax: (07) 3102 9926 | €: pauttoulspaceneiau |wwwsoulspaceceman | As indicated @A3 2982
3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA, Q
RELEVANT SAA STANDARDS AND LOCAL AUTHORITY REQUIREMENTS. (LOT 289) 17 FERGUSON STREET OSA Reg Wheaa7s F Acie: 23 Pao Stns Sune Sea. ne S80 ate ATE foaiz010 oN
4, WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF ? A . 09/17/08 |4.01:39 PM Paul Hindes
HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED. SUNSHINE BEACH abe Gans Designs Autuala ith Member EDAD Vee Revers arutioe Cont Packet tour Esicincy Conant
S. REFER ANY ERRORS 10 THE DESIGNER BEFORE COMMENCEMENT OF DRAWING Ho REVISION

CONSTRUCTION
6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
USED WITHOUT THE CONSENT OF THE AUTHOR, .

BIA members.

LAWRIE & NATALIE CRANLEY AND [AN MUNDY

 

 

 

 

(Oi

— so

Person

 

WDO‘1

 

 

 

 

Used in these records

About this file

File size
2.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

TPC 1354 - Change a Development Approval [As Published].pdf · 2.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.