                                                                                               Burgess Creek
                                                Receiving Environment Monitoring Program
                                                                                      Annual Review 2022
Table 11. Percentage compliance in 2021 with Recreational Water Quality Limits (ANZECC,
2000) for Burgess Creek.
                   Biological Indicators          % Compliance at Monitoring Site
  Water Quality
                   Guideline (ANZECC,
   Parameter                               B1     B2      B3     B5     B6      B8   SW3
                          2000)
                                          150
                        Primary       cfu/100mL      0         92     92        0       25       33        0
   Enterococci                           1000
                       Secondary      cfu/100mL     50         92    100        27      75       67       42
                                          35
 Thermotolerant         Primary       cfu/100mL     17         33    100        0       67       33       17
   Coliforms                              230
                       Secondary      cfu/100mL     75      100      100        82      92       67       92
                                         1260
         E coli        Secondary      cfu/100mL     92      100      100       100    100       100       92

5.9 Compliance of treated wastewater releases with Environmental
    Authority EPPR008691113
A review of the compliance monitoring data for Noosa STP (Table 12, Figure 54 and
Figure 55) shows that there were 0 reported non-compliances with the water quality
characteristic release limits.

Table 12. Mass Load limits at the Noosa STP for 2021
 Nutrient          Average         Nitrogen          Nitrogen         Phosphorus             Phosphorus
 Parameter         Annual          50th                               50th Percentile
                   Flow            Percentile

 Units             ML/year         mg/L              Kg/year          mg/L                   Kg/year

 Limit                 5 110              5              25 550                 1                 5 110

 Mass Load             3763             4.72             16 658                0.14                510




This document may not, in whole or part, be copied, photocopied, reproduced,
or translated without prior consent from the CEO, Unitywater.                                Page 45 of 64

                                                                                                       Page 259 of 310

Log in to download the original (ca3d9e722f.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.