        1907NOO_         G      Tree Removal        Plan,   prepared    by    Enrich 19/06/2023
                                Architecture
        PD_A_001.2

        01737 LC_01      B      Landscape Site Plan,         prepared    by    View March 2023
                                Landscape Architecture

        01737 LC_02      B      Landscape Concept Plan, prepared by View March 2023
                                Landscape Architecture

        01737 LC_03      B      Landscape Detailed Concept Plan, prepared by March 2023
                                View Landscape Architecture

        01737 LC_04      B      Suggested Planting Character, prepared by View March 2023
                                Landscape Architecture

      Reference Documents

        Plan No.         Rev.   Plan/Document Name                                   Date

        J000542          2      Bushfire Hazard Assessment & Management 21/03/2023
                                Plan, prepared by North Coast Environmental
                                Services

        J000542          1      Bushfire Evacuation Plan, prepared by North 08/12/2022
                                Coast Environmental Services (Appendix 2 of the
                                Bushfire Hazard Assessment & Management
                                Plan, prepared by North Coast Environmental
                                Services)

        WBFE965-         OP1    Building Bushfire Safety and Spread Prevention 22/03/2023
        001-2023                Strategy,   prepared     by   Walkerbai   Fire
                                Engineering

      Building Height
47.   The maximum height of the development must not exceed 9 metres above the ground level
      for the roof of the Banksia building only, in accordance with the approved plans. All other
      buildings in the development must not exceed 8 metres in height above the ground level
48.   Certification must be submitted to Council from a Registered Cadastral Surveyor (Qld) which
      certifies that the buildings do not exceed the maximum height requirement of this Decision
      Notice.
      Nature and Extent of Approved Use
49.   The total number of persons residing on the premises at any one time must not exceed 130.
      Performance Bond
50.   Security in the form of a cash bond or trading bank guarantee to the sum of $30,000 must
      be submitted to Council, to secure performance of all conditions of this approval, prior to the
      issue of a Development Permit for Operational Works. The cash bond or trading bank
      guarantee will be returned on performance of the conditions of approval less any costs
      incurred by Council in respect of enforcing performance of this permit. Council reserves the
      right to call upon the bond or guaranteed sum to effect compliance with conditions.




                                                                                        Page 2 of 5

                                                                                              Page 77 of 310

Log in to download the original (ca3d9e722f.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.