Structural Plans 20220173 - 10 Natasha Structural Issue 190123 · OPW22/0299
Plans and drawings: the text below has words only, no drawings.
Very large file (10.3 MB): may take a few minutes to open.
Original PDF page 41, section 1. The text section number identifies this passage in the reader.
4N16-200 EXTRA
N16-200
N16-200
3000 LONG
N16-200 N16-200 N16-200 N16-200
4N16-200 EXTRA
3000 LONG
K4, K5 & K6 VILLA ROOF BOTTOM REINFORCEMENT PLAN K4, K5 & K6 VILLA ROOF TOP REINFORCEMENT PLAN
SCALE 1 : 75 SCALE 1 : 75
SLAB BOTTOM REINFORCEMENT NOTES SLAB TOP REINFORCEMENT NOTES
• LAPS TO SLAB REINFORCEMENT TO BE AS PER TABLE ON • LAPS TO SLAB REINFORCEMENT TO BE AS PER TABLE ON
DRAWING S001 UNLESS NOTED OTHERWISE ON PLAN DRAWING S001 UNLESS NOTED OTHERWISE ON PLAN LAY 2nd & 3rd
• REINFORCEMENT IS TO BE DISPLACED AROUND • REINFORCEMENT IS TO BE DISPLACED AROUND
PENETRATIONS, NOT CUT. PROVIDE N16-200 INFILL BARS. PENETRATIONS, NOT CUT. PROVIDE N16-200 INFILL BARS.
• PROVIDE 1 N16x1500 LONG TRIMMER BAR AT ALL RE-ENTRANT • PROVIDE 1 N16x1500 LONG TRIMMER BAR AT ALL RE-
CORNERS. ENTRANT CORNERS.
LAY 1st & 4th
• ALL DISTRIBUTION REINFORCEMENT TO BE N12-300 U.N.O. • ALL DISTRIBUTION REINFORCEMENT TO BE N12-300 U.N.O.
LAP LENGTH
300 TYP. REFER DRG. S001
LAYING SEQUENCE U.N.O.
BARS REQUIRED IN OTHER SEQUENCE
ARE TAGGED ON PLAN THUS:-
(1) LAID 1ST, (2) LAID 2ND
LAP LENGTH 300 TYP. (3) LAID 3RD, (4) LAID 4TH
REFER DRG. S001
SLAB BOTTOM REINF. SCHEMATIC SLAB TOP REINF. SCHEMATIC
2 N20 TRIMMERS TOP
BEAM BOTTOM REINFORCEMENT NOTES BEAM TOP REINFORCEMENT NOTES 300
AND BOTTOM
TYPICAL U.N.O.
• LAPS TO BEAM REINFORCEMENT TO BE AS PER TABLE ON • LAPS TO BEAM REINFORCEMENT TO BE AS PER TABLE ON MIN.
DRAWING S001 UNLESS NOTED OTHERWISE ON PLAN DRAWING S001 UNLESS NOTED OTHERWISE ON PLAN
• FOR PENETRATIONS LESS THAN Ø100 LOCALLY DISPLACE • FOR PENETRATIONS LESS THAN Ø100 LOCALLY DISPLACE SIDE
SIDE FACE REINFORCEMENT AND PROVIDE 1 N16 x 600 FACE REINFORCEMENT AND PROVIDE 1 N16 x 600 LONG TO EACH SLAB REINFORCEMENT
MIN.
300
LONG TO EACH PENETRATION FACE AT EACH SIDE OF PENETRATION FACE AT EACH SIDE OF BEAM. PENETRATIONS COGGED AT PENETRATION.
BEAM. PENETRATIONS LESS THAN Ø100 MAY NOT BE LESS THAN Ø100 MAY NOT BE SHOWN ON PLAN.
SHOWN ON PLAN. • ALL BEAMS TO HAVE N12 LIGS AT 300 CRS. UNLESS NOTED
• ALL BEAMS TO HAVE N12 LIGS AT 300 CRS. UNLESS NOTED OTHERWISE ON PLAN.
OTHERWISE ON PLAN.
LAP LENGTH
300 TYP. LAP LENGTH
REFER DRG. S001
TYP.
NOTE:
FOR PENETRATIONS LESS THAN 300 SQ. REINFORCEMENT
LAP LENGTH 300 TYP. IS TO BE DISPLACED NOT CUT. PROVIDE N16-200 INFILL BARS.
REFER DRG. S001
TYPICAL SLAB PENETRATION DETAIL
BEAM BOTTOM REINF. SCHEMATIC BEAM TOP REINF. SCHEMATIC SCALE 1:20
INFORMATION
NOT FOR CONSTRUCTION
Client Status Title
MARK BAIN INFORMATION
K4, K5 & K6 VILLA ROOF BOTTOM & TOP
Drawn By Designed By Approved By
JAL JM JO
REINFORCEMENT PLANS
Project No. Discipline Scale
[email protected] 20220173 STRUCTURAL As indicated (at A1)
Project Name
37 MARY ST NOOSAVILLE, QLD Drawing No. Revision
1 04.11.22 ISSUE FOR INFORMATION JAL JO NOOSA VILLAS
07 5211 1003 S221 1
Rev Date Description By Chk 10 NATASHA AVE & 24 KATHARINA ST, NOOSA HEADS QLD
FULL SIZE ON ORIGINAL 0 10 20 30 40 50 60 70 80 90 100 mm
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Structural Plans 20220173 - 10 Natasha Structural Issue 190123.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.