Skip to the record
NoosaWatch™: The source of truth.

Original source · versioned page text

Appendix C - site and soild evaluation for on site effluent.pdf

of 10
               Appendix C – Site and Soil Evaluation for On Site Effluent




18 July 2025                                       Tim Olah
Ref: 23-068            Planning Report – Proposed Dwelling at 555 Louis Bazzo Dr, Pomona

Log in to download the original (Appendix C - site and soild evaluation for on site effluent.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 9 pages

Page 2

                . . . . Site and Soil Evaluation . . . . .
                                       (On Site Effluent)

                                         Client: T. Olah

                                          Location
                                    555 Louis Bazzo Drive
                                        Pomona, QLD
                                    (Lot 2 on RP806872)


                                 Report No.: 240038 (A)

                                    Date: 22/02/2024




Phone: 0428 310 453
Email: [email protected]
Address: 174 Railway Road, Cooran Qld 4569
Australian Soil Investigations Pty Ltd
ABN: 11147854439

Page 3

ON-SITE EFFLUENT DISPOSAL REPORT:                          Lot 2 on RP806872
                                                           555 Louis Bazzo Drive, Pomona.
Introduction:

Australian Soil Investigations have conducted a Site and Soil Assessment at the above allotment for the purpose of
determining the most suitable means of on-site effluent disposal. On-site testing for this assessment was
performed in accordance with AS 1547-2012-“On-Site Domestic Wastewater Management , Queensland Plumbing
and Wastewater Code and Local Government Requirements.
Field work for this assessment was undertaken on the 05/02/2024.
ASI has been asked to provide a design for a four bedroom dwelling.

Site description:

The allotment is located within the Noosa Council and is contained within a rural area.
The slope within the allotment is generally linear divergent.
The slope within the area best suited for effluent disposal is in the order of 4-5%.

On-Site Assessment:

During our site evaluation consideration was given to the following:

        the available area for the primary siting of absorption areas (Land Application Area) and alternative
         sightings.

        the risk of prejudicing adjoining property and underground water supplies, by seepage or run off from the
         site.

        permeability, soil type and soil depth.

        drainage, and envisaged seasonal changes in ground water level.

        general climate.

        slope and the effects of seepage and water run-off from surrounding higher ground.

On-Site Testing:

Three test holes were excavated in the positions shown in the attached site sketch. These holes were 100mm
diameter x 600 mm deep for the purpose of site soil assessment in accordance with the AS 1547 - 2012. A further
100mm diameter hole was excavated to determine the soil profile. The site was then classified in accordance with
AS 1547 – 2012 On-Site Wastewater Management for the purposes of effluent disposal.

Results:
Site Observations
                                                                                    Yes                No
        Suitable Area for siting a Land Application Area                             

        Adequate area for a Reserve area                                             

        Setback requirements to waterways

        Is there Adequate Soil Depth above rock or the water table                   

        Is the Soil Type Satisfactory                                                

        Is the potential of runoff from the proposed area OK                         

        Is there a potential for groundwater seepage                                                     




   AUSTRALIAN SOIL INVESTIGATIONS                              2                              ASI Ref: 240038 (A)

Page 4

Soil Borehole Results



                                 Depth                      Soil Description
                                 00-400                     Silty Clay CL
                                                            Light to med clay, dark brown
                                                            Moist, moderate (Cat 4)

                                 400-900                    Silty Clay CH
                                                            Med to heavy clay, pale brown orange
                                                            Moist, moderate (Cat 5)

                                 2000                       Borehole Terminated
                                                            Dense gravel


Constant Head Method permeability results


The following design criteria is applicable for the following disposal methods:

                                                                  1            2               3
                             Fall                  (mm)           25          25              25
                             Time                  (mins)         52          60              43
                                                   (secs)         12           4              58
                          Permeability             (Ksat)       0.0766       0.0666          0.0910
                         Soil Category                            5            5               5
                           Structure                           Moderate     Moderate        Moderate


Indicative Permeability

         Test Site:                        1                       2                      3
        Soil Category                      5                       5                      5
          Structure                    Moderate                Moderate               Moderate
        Permeability                   0.06-0.12               0.06-0.12              0.06-0.12
             DIR                           3                       3                      3

Recommendations:

Based upon our Site and Soil Assessments we recommend the following method of On-Site Effluent Disposal
should be used.

For the treatment of the Effluent we recommend;


      Advanced Secondary WasteWater Treatment System (AWTS)
(NOTE: The system chosen must satisfy both the Queensland Plumbing and Wastewater Code and AS 1547 - 2012
On-Site Domestic Waste Water Code and be approved for use by the Local Shire/Council governing the allotment.)

For the disposal of the treated effluent within the Land Application Area we recommend;

      A Pressurised Surface Reticulated Irrigation System
(NOTE: Where Surface irrigation is used the treated effluent shall be disinfected with chlorine prior to dosing of
the Land Application Area.)


   AUSTRALIAN SOIL INVESTIGATIONS                                      3                               ASI Ref: 240038 (A)

Page 5

The size of the Land Application Area is calculated as follows:

  Minimum requirement       q       120           litres per person per day   AS 1547 –2012 Appendix H1

      Water Supply               Tank Water

  Number of persons =                 6                                           AS 1547 Table J1


      Total Volume          Q=      5040      L/week

      Soil Category                   5                                           AS 1547 Table M1

  Indicative permeability         0.06-0.12                                       AS 1547 Table M1

           DIR                       21       mm/week                             AS 1547 Table M1

                                                2
      Disposal Area         A=      240       m

WE RECOMMEND THAT A MINIMUM LAND APPLICATION AREA OF 240m 2 BE PROVIDED.

The Irrigation System should be designed in accordance with AS 1547 – 2012 and comply with all relevant
statutory requirements.

Construction Guidelines for Land Application Areas:

Surface Irrigation

Consists of a reticulated pressurised irrigation system that uses a series of surface sprinklers to equally distribute
the treated effluent across the Land Application Area. This system allows vegetation within the area to directly
benefit from such watering which also assists in disposal of the effluent via evapo-transpiration. Points to consider
in the construction of the area include the following:


             To avoid runoff from the area it should be as level as possible. Any steep sloping areas should be
              terraced or retained and filled.
             Rainwater shall be diverted around the perimeter of the area by use of open catch drains or bunding.
              Similarly a retention bund should be constructed around the low side of the area to retain any effluent
              overflow.
             Sprinklers with a throw of not more than one meter shall be used and produce coarse droplets
              (instead of a fine mist) to minimise the risk of aerosol dispersion and wind drift of effluent. The
              plume height shall not be more than 500 mm above the finished surface of the irrigation area.
             The treated effluent must not be used for the irrigation of fruit or vegetables.
             Siting of surface irrigation shall be in a location away from regular pedestrian traffic and recreational
              areas, so there is no risk of direct spray or wind driven spray onto such areas.
             The area should not be within vehicle paths or be near children’s play areas. Refer to Queensland
              Plumbing and Wastewater Code for all required setback distances.
             Treated effluent quality must conform to AS 1547 - 2012 and the Queensland Plumbing and
              Wastewater Code.

We have attached a site plan showing the proposed position of the Land Application Area and also some details
highlighting the construction techniques required for surface irrigation.




   AUSTRALIAN SOIL INVESTIGATIONS                                  4                             ASI Ref: 240038 (A)

Page 6

Preparation of irrigation area:

When a proposed irrigation area has a low permeability, it is particularly important to ensure that the permeability
of the soil in the irrigation area is improved and maintained and that there is an adequate cover of porous and
fertile topsoil to act as immediate storage of effluent applied to it, and to support rapid growth of vegetation on the
area to maximise evapo-transpiration.


Requirements of irrigation system:

All irrigation pipe work and fittings shall comply with all parts of AS 1477 or AS 2698.2. The distribution irrigation
lines should be buried to a minimum depth of 100mm. There shall be no cross connection between any irrigation
pipe work and the potable water supply. Any pipe work used for the transport of effluent included treated effluent
must be lilac in colour.

Along the boundary of the surface irrigation area there shall be at least two warning signs clearly visible to inform
the occupants of the premises that recycled water is used for irrigation. Each sign shall comply with AS 1319 and
have:

      (a)    lettering visible at 3m and
      (b)    wording:              Recycled Water
                                   Avoid Contact
                                   DO NOT DRINK

Prior to the use of the system, the warning signs and the landscaping and surface preparation must be completed.


Sighting of the Land Application Area:

The current Code of Practice for On-site Sewerage Facilities (Queensland Plumbing and Wastewater Code) provides
minimum horizontal/vertical separation distances for Land Application Areas. They are as follows;

             Surface Land Application Areas (ADVANCED SECONDARY)
             Property Boundaries Upslope from the Area     -      2.0m
             Property Boundaries Downslope from the Area   -      4.0m
             Dwellings or buildings                        -     10.0m
             In ground swimming Pools                      -      6.0m
             In-ground potable Water Tanks                 -      6.0m
             Dams, Watercourses or Bores                   -     10.0m
             Vertical distance to water table              -      0.6m
             Driveway                                      -      2.0m                      (Upslope);
             -                                             -      4.0m                      (Downslope)
             Footpath                                      -      1.0m                      (Upslope);
                                                           -      2.0m                      (Downslope)

NOTE:- REFER TO QUEENSLAND PLUMBING AND WASTEWATER CODE FOR SITING OF ON
       SITE SEWERAGE FACILITY FOR LOCATION OF TREATMENT PLANT. TREATMENT
       PLANT MUST BE 150mm ABOVE Q100 FLOOD LEVEL.

In no instance shall Effluent be used for irrigation of fruit or vegetables.

No Vehicle loading or recreational areas to be applied or constructed within the Land Application
Area.




   AUSTRALIAN SOIL INVESTIGATIONS                              5                                ASI Ref: 240038 (A)

Page 7

System Maintenance:

The owner of the property shall ensure that all manufacturers maintenance procedures are undertaken in
accordance with the local authority and the manufacturers recommendations for what ever system is installed.
The system must be inspected/tested on a regular basis in accordance with the manufacturers requirements and
all Statutory requirements from relevant local and state government agencies.
NOTE: No Antibacterial products or disinfectant to be used in the system. Refer to manufacturers
guidelines on safe products to be used in the system.



System Installation:

Installation of the system must be undertaken by a qualified plumber in accordance with local authority
requirements and in accordance with the relevant Australian Standards and Australian Building Code.
NOTE: The system is not to be installed or utilized without Plumbing approval from Council.
 The building is not to be occupied without Building and Plumbing approval. Permit Numbers are to
be provided to the installer and designer.


Definitions:

Design Loading Rate (DLR)
The long term acceptance rate (LTAR), reduced by a factor of safety, expressed in L/m 2/day or mm/day as applied
to the horizontal design area of a land application system.
Design Irrigation Rate (DIR)
The loading rate that applies to the irrigation of a land application area with effluent of a secondary quality. It is
expressed in L/m2/day or mm/week. If a spray irrigation system is used, the secondary effluent is subject to
continuous disinfection.
Durable Aggregate
An aggregate with the grading requirements specified in AS 2758.1 for single-size course aggregate for nominal
sizes from 20mm - 40mm.
Dry Vault
Commonly known as “composting toilets”, a chamber that receives and treats human and domestic organic waste
using a biological degradation or dehydrating process. The only water used is for cleaning or assisting the
biological degradation process.
Geotextile
Any permeable durable synthetic textile material used with foundations, soil, rock, earth or other geotechnical
engineering related material.

Land Application Area
The designated area of land and reticulation system used for the disposal of the treated effluent.
LTAR
The long term average rate an effluent can be adsorbed into the soil of a disposal system, expressed in litres per
square meter per day. LTAR is dependent on effluent quality, permeability and organic loading.
Permeability
The rate clean water is transmitted through a soil, expressed in meters per day.
Terrace
Where the trenches are in an area where the slope exceeds 15% (approximately 1 in 7) they must be terraced.
Water Reduction Fixtures
Fixtures include dual flush water closets, shower flow restrictors, aerator taps and water conserving washing
machines.




   AUSTRALIAN SOIL INVESTIGATIONS                              6                               ASI Ref: 240038 (A)

Page 8

Report Limitations:

The log sections in this report should be representative of the soil conditions over this site, however, soil conditions
can change dramatically over short distances. The person responsible for installing the system must observe the
soil profile and ensure it matches the soil profiles recorded in this report. If soil conditions differ from those
recorded by us, we must be immediately notified so that further investigation can be carried out and the system
design modified if necessary. This work may involve additional fees and costs. This company will not accept any
responsibility for additional costs to any party as a result of soil variations.

In writing this report, we have also considered all the information supplied to us by our client. Should the client or
his agent have omitted to supply us with relevant information, our report may be irrelevant and/or inappropriate.
We do not take responsibility for the consequences in such cases and we will make an additional charge if as a
result, more testing or rewriting of this report is necessary.

The operation of the disposal system is dependent upon the hydraulic load, the type of the material entering the
system and the maintenance of the system. As these factors are beyond the control of this company we do not
take any responsibility for the long term adequacy of any disposal system constructed on this site or the
consequences of its malfunction.




WADE HOLMES – QBCC 1120066
for and on behalf of:
AUSTRALIAN SOIL INVESTIGATIONS – QBCC 15072110




   AUSTRALIAN SOIL INVESTIGATIONS                               7                                ASI Ref: 240038 (A)

Page 9

                                                                                          Revision     Description                         Date
                                                                                          .            .                                   .
                                                                                          .            .                                   .
                                                                                          .            .                                   .




   Surface
   Drainage          Good.

  Vegetation       Grasses &
                 Scattered Trees

       BH 2
               Borehole location.
                                                                      ABN11 147 854 439
               Slope                                                                          Title:       SITE PLAN - On-Site Effluent Disposal
               measured as a percentage gradient from
                                                         AUSTRALIAN
               high ground to low ground.               SOIL INVESTIGATIONS                   Project J. Ashworth, 14 Drake Street
                                                                                                      Proston
DO NOT DIMENSION OFF THIS DIAGRAM.                                                                                                         Rev.
                                                                                              Date: Jan 2024           Drg No.240002-ABS          .

Page 10

                  Revision   Description                     Date
                  .                                          .
                  .          .                               .
                  .          .                               .




T, Olah1383 555                  AUSTRALIAN
Louis Bazzo Dr           SOIL INVESTIGATIONS
    Pomona
                      STD DETAIL           Drg No. 240038-Detail

The supporting record