Council archive · source document
Planning Report · MCU13/0064
Probable solutions
Specific Outcomes Proposal
(if code assessable)
S6.5 Any flood lighting is restricted Complies
to the types that give no upward Flood lighting complies.
component of light where mounted
horizontally (i.e. a full cut off
luminare).
O7 Noise originating from the use S7.1 The court is not used between Complies
of the tennis court does not have a the hours of 10:00pm and 6:30am The tennis court will not be used
detrimental effect on the amenity of the following day. between the hours of 10:00pm and
the area or cause nuisance to 6:30am the following day.
neighbouring residents.
Traffic and access S8.1 Visitor Accommodation is Complies - Alternative Solution
O8 Safe vehicular access is directly accessible from a sealed The use is situated on an island
provided to and from the site road or a good standard graveled with boat/ferry access only.
without adversely impacting on the road;
safety of the road network; AND
S8.2 Driveways do not exceed a Not Applicable
gradient of 1 in 4 (25%).
AND
S8.3 Where the site gains access Not Applicable
from part of the Major Road
Network, vehicle manoeuvring
areas are provided in accordance
with Section 3 of AS 2890.1 Parking
Facilities (Part 1: Off-street
Carparking) so vehicles enter and
leave the site in a forward gear.
Water supply and conservation S9.1 & S10.1 Where outside a Complies – Alternative Solution
O9 An adequate, safe and reliable reticulated water service area— The site is connected to reticulated
water supply is available to the a) a rainwater tank of a minimum water supply service.
premises. capacity of 4,000 litres is to be
AND. provided for each accommodation
unit; and
b) there is to be on the lot a dam,
swimming pool or water tank
accessible for use by the fire
brigade that contains at least 5,000
litres of water.
Advisory note
The 5,000 litres required can be
included within the water required in
S8.2 & S9.1 providing it is accessible for
the purpose of fire fighting at all times
and not used for other domestic
purposes.
Effluent disposal Complies
O11 The provision of an effluent No solution provided The site contains an approved
disposal system is provided to effluent disposal system. Refer to
maintain acceptable public health Advisory note accompanying Assessment of
standards and avoid environmental PSP24 – Effluent Disposal details Existing Wastewater Infrastructure
harm. requirements for the design and siting of report prepared by Future-plus
effluent disposal systems where located
Environmental.
outside a sewerage service area.
Compliance with PSP24 will be
considered as part of Council’s
assessment of the plumbing and
drainage application.