         GENERAL NOTES:                                                                                                                                                                                                                                                                                                                                                                                                                    LEGEND
                                                                                                                                                                                                                                                                                                                                                                                                                                           AC               Airconditioning condensor unit to Builder Spec
                                                                                                                                                                                                                                                                                                                                                                                                                                           AX1              JH 'Axon' Cladding - Paint Finish. Resene Half Iron
         DESCRIPTION:                                                              PENETRATIONS                                                                  SOUND TRANSMISSION AND WALL / FLOOR INSULATION                            EXTERNAL WALLS                                                                            LANDSCAPING (Hardscape & Softscape)
                                                                                                                                                                                                                                                                                                                                                                                                                                           BAL01            Toughed glass balustrade with powdercoated top rail &
         Proposed mixed use building comprising of Cafe, Orthodontics              All penetrations through fire rated members must be fire protected            The floors must have an Rw + Ctr (airborne) not less than 50 and an       All external walls that are to be 190mm thick Blockwork shall be                          Refer to Landscape Architect's drawings for details.
                                                                                                                                                                                                                                                                                                                                                                                                                                                            mullions
         Tenancy & 6 sole occupancy Units.                                         in accordance with a tested prototype to maintain the fire resistance         Lnw + Ci (impact) not more than 62 if the floor separates sole            reinforced and solid core filled concrete blockwork in accordance                                                                                                                               BAL02            Powdercoated aluminium AS1428.1 compliant handrail,
                                                                                                                                                                                                                                                                                                                                     POOL
                                                                                   of the element being penetrated in accordance with NCC clause                 occupancy units or a sole occupancy unit from a plant room, lift          with Structural Engineer's drawings. Provide a proprietary type                                                                                                                                                  SHS profile. Colorbond Paperbark
         DEVELOPMENT APPROVAL:                                                                                                                                                                                                                                                                                                       A pool and spa safety barrier must be provided in accordance with
                                                                                   3.12-3.15.                                                                    shaft stairway, public corridor, public lobby or the like or parts of a   waterproof render and membrane paint finish to all walls. Render                                                                                                                                BFC              Broom Finish Concrete Slab
         Refer MCU/DA report no. MCU10 2076.01                                                                                                                                                                                                                                                                                       Queensland Development Code MP3.4, AS 1926.1 & 2 and the
                                                                                                                                                                 different classification. Install an approved and tested / certified      and paint finishes to be applied by an approved applicator in                                                                                                                                   BHD              Bulkhead
                                                                                   DISABILITY PROVISIONS                                                                                                                                                                                                                             Building Act (Chapter 8). Resuscitation signs must be mounted in                                      BRR              Floor Bearer
         EXISTING BUILDING:                                                                                                                                      proprietary type applied acoustic underlay to all internal tiled areas    accordance with manufacturer's requirements.
                                                                                   A lift or ramp to serve upper levels is not mandatory (except where                                                                                                                                                                               prominent positions.                                                                                  BN               Basin - refer to Plumbing Fittings Schedule
         3 Exiting buildings are on site. The existing Building used as an                                                                                       where ceilings are not installed to units below.
                                                                                   required to satisfy the items above) however where installed, access                                                                                    EXPANSION / CONTROL JOINTS                                                                A warning sign must be provided to serve the property prior to the                                    CL               Powdercoated aluminium wall mounted folding clothes
         Dental Orthodontic practice is to remain operational throughout                                                                                         The walls separating sole occupancy units must have an Rw + Ctr
                                                                                   must be provided to the entrance door of every unit served by the                                                                                       Provide expansion / control joints in accordance with Structural                          construction of the pool or spa in accordance with Section                                                             line
         construction of the new building. Public access to Existing Building                                                                                    not less than 50. A wall must have an Rw (airborne) not less than 50,                                                                                                                                                                                                     CLG              Ceiling - Refer Reflected Ceiling Plan.
                                                                                   lift. Access must also be provided to and within rooms or spaces for                                                                                    Engineer's drawings. Fill expansion joints with a proprietary type                        233 of the Building Act 1975. The warning sign must be displayed
         is to remain in a safe & compliant manner.                                                                                                              if it separates a sole occupancy unit from a plant room, lift shaft,                                                                                                                                                                                                      CT               Cooktop - refer to appliances schedule
                                                                                   use in common by the residents (e.g. including a cooking facility,                                                                                      water barrier system suitable for location. Install in accordance with                    until a building certifier has provided a certificate in the approved
                                                                                                                                                                 stairway, public corridor, public lobby or the like, or parts of a                                                                                                                                                                                                        EA.CONC          Exposed agregate concrete
         SAFETY IN DESIGN:                                                         sauna, gymnasium, swimming pool, common laundry, games room,                                                                                            manufacturer's requirements.                                                              form stating the pool is a complying pool. The sign must warn
                                                                                                                                                                 different classification.                                                                                                                                                                                                                                                 D.#              Door Number. Refer Door Schedule.
         A saftey in design report has been prepared to Safe Design                individual shop, eating area, or the like) that are served by the lift or                                                                                                                                                                         members of the public in the vicinity of the land that a swimming
                                                                                                                                                                 A wall that separates a bathroom, sanitary compartment, laundry or        FORMWORK / CONCRETE                                                                                                                                                                             DP1              PVC Downpipe - Paint Finish - Colorbond Shale Grey
         Australia. Builder & contractors shall familirise themselves with this    ramp.                                                                                                                                                                                                                                             pool is under construction on the land and that there is potential                                    DR               Clothes dryer. Refer to Appliance Schedule.
                                                                                                                                                                 kitchen in one sole occupancy unit from a habitable room (other           All exposed concrete surfaces and concrete surfaces with applied
         report prior to Demolition works commencing.                              Access is required to and within any level containing accessible                                                                                                                                                                                  danger to young children accessing the land. The sign must be                                         F                Fridge. Refer to Appliance Schedule
                                                                                                                                                                 than a kitchen) in an adjoining unit or separates a sole occupancy        render or paint finish shall be formed with minimum class 2
                                                                                   carparking spaces. In a class 7a carpark, PWD car spaces in                                                                                                                                                                                       placed on, or within 1.5m of the road frontage for the land and be                                    FC1              6mm fibre cement cladding with vertical timber cover
         DEMOLITION:                                                                                                                                             unit from a plant room or lift shaft must be of discontinuous             formwork to achieve uniform quality.
                                                                                   accordance with AS 2890.6 are required at a ratio of 1:100.                                                                                                                                                                                       mounted so that the bottom of the sign is at least 300mm above                                                         strips installed as per Architectural Elevations - Paint
         Contractor responsible to assess existing site conditions and allow                                                                                     construction, i.e. providing a minimum 20mm cavity between 2                                                                                                                                                                                                                               Finish. Resene Rice Cake
                                                                                   Access is required to and into swimming pools with a total                                                                                              CONCRETE COLUMNS                                                                          ground level. The sign must be visible from the road and be made
         for demolition and removal of material as indicated on the                                                                                              separate leaves and for masonry, where wall ties are required to                                                                                                                                                                                                          FC2              JH 'Easy Lap' Cladding. Resene Rice Cake
                                                                                   perimeter greater than 40m except where the pool is for the                                                                                             All concrete columns shall be reinforced concrete in accordance                           of weatherproof material. Lettering on the sign must be not less
         drawings. This includes                                                                                                                                 connect leaves, the ties are of the resilient type and for other than                                                                                                                                                                                                     FT1              Refer Fixtures Schedule.
                                                                                   exclusive use of a sole occupancy unit in a class 2 building (refer                                                                                     with Structural Engineer's drawings. Class of finish to formwork                          than 50mm in height and in a bold style.
         existing floor, wall and roofing material. Contractor responsible to                                                                                    masonry, there is no mechanical linkage between leaves except at                                                                                                                                                                                                          FT2              Refer Fixtures Schedule.
                                                                                   NCC Clause D3.10).                                                                                                                                      columns to be class 2. Provide a proprietary type render and                              Prior to filling the pool to a depth exceeding 300mm the building                                     FT3              Refer Fixtures Schedule.
         assess presence of asbestos and allow for safe removal of                                                                                               the periphery.
                                                                                   Every passenger lift must comply with NCC Clause E3.6 (disability                                                                                       waterproof membrane paint finish to all columns. Render and paint                         certifier must inspect and provide confirmation (form 17) that the                                    FG               Fixed glass- refer to Window Schedule.
         hazardous materials.                                                                                                                                    If a duct, soil, waste or water supply pipe including a duct or pipe
                                                                                   requirements).                                                                                                                                          finishes to be applied by an approved applicator in accordance with                       pool safety barriers are in accordance with the Building Act.                                         FL               Flashing
         Measures are to be taken to minimize dust & noise disruption such                                                                                       that is located in a wall or floor cavity, serves or passes through
                                                                                   For narrow accessways, passing spaces and turning spaces must be                                                                                        manufacturer's requirements.                                                              Backwash and excess pool water must be drained in accordance                                          FLJ              Floor Joist
         as providing hoarding separation between new construction works                                                                                         more than one sole occupancy unit, the duct or pipe must be                                                                                                                                                                                                               FSC              Fascia
                                                                                   considered in accordance with NCC D3.3 (20m intervals).                                                                                                                                                                                           with Local Authority requirements.
         and existing                                                                                                                                            separated from the rooms of any sole occupancy unit by                    TANKING                                                                                                                                                                                         FWG              Floor Waste Gully
                                                                                   Braille signage is required to common area sanitary facilities.                                                                                                                                                                                   In accordance with NCC Clause G1.1(c), a water recirculation
         club operations which are maintained during the construction                                                                                            construction with an Rw + Ctr (airborne) not less than 40 if the          Provide proprietary type waterproof membrane tanking system to                                                                                                                                  G#               Gate & number - refer to door schedule.
                                                                                                                                                                                                                                                                                                                                     system in a swimming pool with a depth of water more than 300mm
         period.                                                                   STAIRS, HANDRAILS, AND BALUSTRADES                                            adjacent room is a habitable room (other than a kitchen) and not          all balconies, terraces, blockwork window reveals, planters, slabs                                                                                                                              GU               Colorbond Half Round Gutter, Shale Grey
                                                                                                                                                                                                                                                                                                                                     must comply with AS 1926.3. A spa pool must comply with AS                                            GD               Drain with SS grate
         Demolition contractor to be familiar with existing operational in         The stairways must be not less than 1000mm in clear width.                    less than 25 if the adjacent room is a kitchen or non- habitable          over carpark walls, retaining walls and the like to ensure a
                                                                                                                                                                                                                                                                                                                                     1926.3 except the specified distance between two outlets                                              HC               Hose Cock
         ground and overhead infrastructure which traverses the site and           Stairways must have constant riser dimensions not greater than                room.                                                                     watertight finish. To be installed in accordance with manufacturer's
                                                                                                                                                                                                                                                                                                                                     connected to a common line may be not less than 600mm. All                                            HR               Handrail - timber with powdercoated metal wall brackets.
         take steps to protect                                                     190mm and constant going dimensions not less than 250mm. Not                  If a storm water pipe passes through a sole occupancy unit, the pipe      specifications and shall be applied by an approved applicator.
                                                                                                                                                                                                                                                                                                                                     fences & balustrades enclosing swimming pool & overflow pool to                                                        Refer to schedules
         during construction.                                                      more than 18 risers are permitted within a single flight. Stair treads        must be separated from the rooms of any sole occupancy unit by
                                                                                                                                                                                                                                           WATERPROOF CONCRETE MEMBRANE                                                              comply with NCC & AS 1926.1 & AS 1926.2.                                                              HWU#             Hot water unit
         Extent of demolition to include all above and below ground                must have a non-slip finish and a contrasting nosing.                         construction with an Rw + Ctr (airborne) not less than 40 if the                                                                                                                                                                                                          INS              Insulation
                                                                                                                                                                                                                                           Reinforced concrete roof slabs are to be poured with integral fall to
         structure sufficient to allow construction of new building.               Where it is possible to fall greater than 1000mm to an adjacent               adjacent room is a habitable room (other than a kitchen) and not                                                                                                                                                                                                          J.##             Joinery Type #
                                                                                                                                                                                                                                           drains. Minimum fall to drains shall be 1:150. Finish with proprietary
                                                                                   surface, balustrading must be provided in accordance with Clause              less than 25 if the adjacent room is a kitchen or non-habitable room.                                                                                                                                                                                                     LIN              Linen cupboard - refer to Joinery Drawings
         DRAWINGS                                                                                                                                                                                                                          type trafficable membrane, to be installed in accordance with                                                                                                                                   M                Shower mixer
                                                                                   D2.16 of the NCC with balustrades extending not less than 1000mm              Prior to construction, details of the proposed construction method
         Do not scale off drawings. Dimensions take preference over scale.                                                                                                                                                                 manufacturer's requirements and shall be applied by an approved                                                                                                                                 MV               Mechanical room ventilator
                                                                                   above floor level or 865mm above the nosing of a stair. Balustrades           to achieve this requirement must be submitted to the satisfaction of
                                                                                                                                                                                                                                           applicator. Provide all necessary accessories, covers, laps, etc. to                                                                                                                            NGL              Natural Ground Line - Refer to Natural Ground Survey
         SET OUT                                                                   must not have any gaps that would permit a 125mm sphere to                    the Building Certifier.
                                                                                                                                                                                                                                           ensure a watertight finish. Application shall be such that ponding                                                                                                                              ORS              Open Riser stair
         Builder to confirm the set out and all levels and dimensions on site      penetrate. Where it is possible to fall greater than 4m to an adjacent        A flexible coupling must be used at the point of connection                                                                                                                                                                                                               P#               Post/ column.
                                                                                                                                                                                                                                           does not occur. Colour of membrane shall be selected.
         prior to the commencement of the building works.                          surface, balustrades must have no climbable elements between                  between the service pipes in a building and any circulating or other                                                                                                                                                                                                      PB               10mm Plasterboard with paint finish - Resene 'Rice Cake'
                                                                                   150mm and 760mm above floor level (including hose cocks, A/C                  pump.                                                                     EXTERNAL APPLIED EXTERNAL FINISHES                                                                                                                                                              PG1              Timber framed open pergola to detail. Paint finish
         CONSTRUCTION                                                                                                                                                                                                                                                                                                                                                                                                                                       Resene 'Rice Cake'
                                                                                   condensers on balconies). Where it is possible to fall greater than                                                                                     All applied external membranes / finishes shall be in accordance
         All construction shall comply with the requirements of the Building                                                                                     HEALTH AND AMENITY                                                                                                                                                                                                                                                        PU               Purlin
                                                                                   4m out of a window, balustrades must extend to a height not less                                                                                        with NCC Requirements and AS1530.1 for Non-Combustibility.
         Code of Australia 2019 Volume 1 for class 2, 6, 7a, & 9b Building.                                                                                      Toilet doorways within 1200mm of the pan must have lift off hinges,                                                                                                                                                                                                       PV#              Concrete Pavers, lightly exposed agregate
                                                                                   than 865mm above floor level to protect that window. Staunchions
         Type C construction. Building Act 1975. Building Regulations 2006                                                                                       slide or swing outwards.                                                  WATERPROOFING INTERNALLY                                                                                                                                                                        R                Tiled recess in tiled wall - Refer joinery detail
                                                                                   to be @ 1250mm crs. max.                                                                                                                                                                                                                                                                                                                                RBW1             Rendered 190 series blockwork. White
         and all referenced Australian Standards.                                                                                                                A storm water drainage management system in accordance with               Waterproofing of internal wet areas shall comply with AS 3740.
                                                                                                                                                                                                                                                                                                                                                                                                                                           RBW2             Rendered 290 series blockwork letterbox enclosure. White
                                                                                   EXTERNAL STAIRWAYS                                                            AS/NZS 3500.3 must be provided (building drainage and civil               Provide a proprietary type liquid or sheet membrane system and
         ENGINEERING                                                                                                                                                                                                                                                                                                                                                                                                                       RS1              Colorbond Custom Orb Roof Sheeting, 'Shale Grey'
                                                                                   All external stairways shall be in accordance with part D1.8 of the           drainage). The system must be designed and certified by an RPEQ           fall to wastes.                                                                                                                                                                                 S                Sink
         To be read in conjunction with Engineer's drawings and soil report.
                                                                                   NCC and AS 1428.1. Provision for future upgrade to stairways to               Engineer as complying with the NCC and AS/NZS 3500.3. Any                                                                                                                                                                                                                 SE#              Shot Edge hardwood timber decking
         Refer to engineering drawings for structural design, footing and                                                                                                                                                                  TIMBER
                                                                                   meet AS 1428.1 requirements, tactile indicators, perimeter handrail           cutting or filling of the site, or construction of retaining walls or                                                                                                                                                                                                     SC               Structural Column Concealed within wall
         slab, tie down, bracing and all structural details.                                                                                                                                                                               All timber to be in accordance with the NCC, Standards Australia AS                                                                                                                             SCN01            Timber lattice screen to detail. Colorbond 'Paperbark'
                                                                                   to stairs.                                                                    other structure on site, shall not jeopardize any existing overland
                                                                                                                                                                                                                                           1684.1 and Engineer's Drawings and Termite protected to AS                                                                                                                                      SHR              Shower Head
         CIVIL ENGINEERING                                                                                                                                       flow drainage system or cause ponding or nuisance storm water.
                                                                                   EXIT SIGNS AND EMERGENCY LIGHTING                                                                                                                       3660.1.                                                                                                                                                                                         SF               Structural Footing
         To be read in conjunction with Engineer's drawings. Refer to                                                                                            Hot water, warm water & cooling water systems in a building must
                                                                                   Provide illuminated exist signs and lighting to comply with Section                                                                                                                                                                                                                                                                                     T#               Tiles- refer to Specification
         engineers documents for extent of civil works.                                                                                                          be installed in accordance with AS/NZS 3666.1.                            STEELWORK                                                                                                                                                                                       TF1              Painted vertical shadow box timber paling fence, to detail
                                                                                   E4.2 and E4.7 of the NCC and AS 2293 part 1. Refer to Electrical
                                                                                                                                                                 Roof coverings must be provided in accordance with Clause F1.5 of         All steelwork, fittings and fixtures shall be hot dipped galvanised,                                                                                                                            TF2              Standard timber paling fence to Builder Spec
         SEWER CONNECTION                                                          Engineer's drawings.
                                                                                                                                                                 the NCC and AS 1562.1.                                                    stainless steel or of a corrosion resistant material or as noted                                                                                                                                T&G#             Tongue & Groove Hardwood Flooring
         All plumbing points to be connected to sewer as per council
                                                                                   LIFT                                                                          All wet areas must be waterproofed in accordance with AS 3740.            otherwise. Select paint finish.                                                                                                                                                                 TRF              Turf
         requirements and in accordance with Hydraulic and Civil                                                                                                                                                                                                                                                                                                                                                                           TOW              Top of Wall
                                                                                   A stretcher facility must be provided to serve the lifts and be able to       The floor of each bathroom and laundry located above another sole
         Engineer's drawings.                                                                                                                                                                                                              PLASTERBOARD FINISH                                                                                                                                                                             WB1              JH Linea Weatherboard Cladding with mitered corners,
                                                                                   accommodate a raised stretcher with a patient lying on it                     occupancy unit or public space must be graded to permit drainage
                                                                                                                                                                                                                                           Plasterboard to be finished to level 4 finish and shall be installed in                                                                                                                                 150mm cover. Paint finish Resene 'Rice Cake'
         STORMWATER                                                                horizontally by providing a clear space not less than 600mm wide x            to a floor waste.                                                                                                                                                                                                                                                         WC               Toilet
         All stormwater shall discharge as per council requirements and in         2000mm long and 1400mm high above the floor level.                            Artificial lighting must be provided to the common areas of the           accordance with AS 2589.1.
                                                                                                                                                                                                                                                                                                                                                                                                                                           WM               Washing Machine
         accordance with Hydraulic and Civil Engineer's drawings.                  A warning sign against the use of the lift in a fire must be provided         building in accordance with the NCC (including the energy                 ALUMINIUM AND GLAZING                                                                                                                                                                           PBWA             Plasterboard wet area
                                                                                   in accordance with Clause E3.3 of the NCC. Fire Service controls              efficiency provisions) and AS 1680.0.                                                                                                                                                                                                                                     WPM              Waterproof membrane
         FIRE ENGINEERING                                                                                                                                                                                                                  Shall be in accordance with AS 2048 & AS 1288, and suit site terrain
                                                                                   must be provided to the lift in accordance with AS 1735.2 or                  All toilets and/or wet areas not provided with adequate natural                                                                                                                                                                                                           W.#.##           Window Number
         A Performance Solution has been adopted. Refer Fire Engineers                                                                                                                                                                     category. Aluminium framing shall be select powdercoated unless
                                                                                   Appendix A of AS 1735.1.                                                      ventilation must be exhausted to outside in accordance with AS            noted otherwise.
         report.
                                                                                   Lifts to comply with Clause E3.6 of the NCC, facilities for people with       1668.2
         POWER CONNECTION                                                          disabilities.                                                                 Habitable rooms must be served by natural lighting through glazed         TILING / CONCRETE FLOORS
         Connect mains supply to meter panel via underground connection            Access to lift pits must comply with NCC Clause D1.17. Access to lift         windows having an area not less than 10% of the floor area they           Concrete floor finish tolerance shall be class B. Floor grinding
         in accordance with Electrical Engineer's requirements.                    pits may be through the lowest landing doors where the pit is not             serve in accordance with NCC Clause F4.1. Natural ventilation must        and/or floor topping with flooding of levelling compound shall be
                                                                                   more than 3m deep, otherwise compliance with NCC Clause                       be provided by permanent windows, doors or other devices which            allowed for to ensure suitable surface finish for the laying of floor
         TERMITE PROTECTION                                                                                                                                                                                                                tiles.
                                                                                   D1.17b is required.                                                           can be opened having an aggregate opening or openable size not
         Provide an approved proprietary type termite protection barrier to
                                                                                   Doors shall be FRL -/60/- Fire doors to comply with NCC section               less than 5% of the floor area of the room required to be ventilated.     FLOOR SURFACES
         concrete slab and retaining walls as per manufacturer's
                                                                                   and AS 1735.1.                                                                                                                                          Must be suitable to prevent slips (Standards Australia Handbook
         specification and in accordance with AS 3660.1 and the NCC.                                                                                             ENERGY EFFICIENCY
                                                                                   FIRE HOSE REELS, HYDRANTS AND FIRE SPRINKLERS                                 The building must be constructed to satisfy the energy efficiency         197 & AS/NZS 4586), trips and falls and be impervious to liquids
         VERMIN PROOFING                                                                                                                                                                                                                   where spillage or wash down is likely. Floors must be suitably
                                                                                   A fire hydrant system must be provided to serve the proposed                  provisions of Section J of the NCC.
         Ensure all soffits, eaves overhangs and under floor areas are vermin                                                                                                                                                              graded to drain off liquids where spillage or wash down is likely to
                                                                                   development in accordance with AS 2419.1 and shall be provided                ‘Energy efficient lighting’ for a minimum of 80 per cent of total fixed
         proof and bird proofed. This includes both new work and existing                                                                                                                                                                  occur.
                                                                                   where indicated on Hydraulic and Architectural drawings, except as            internal lighting must be provided. ‘Energy efficient lighting’ is
         building.
                                                                                   otherwise permitted by the approved Fire Engineering Report.                  lighting with a minimum output of 27 lumens per watt and excludes         PAINT SPECIFICATION
         Principal Contractor to engage suitably qualified Contractor to
                                                                                   Provision must be made for the disposing of fire hydrant test water           a lamp used in a bathroom for the purposes of radiating heat.             Use Resene or other approved supplier, Specification Sheets for
         assess the project and provide recommendation and quote to
                                                                                   to a suitable drain for the purpose of flow testing.                          Any hard-wired air-conditioners installed must have an EER of at          substrates preparation and application guidelines for instruction on
         supply and install necessary fixtures and fittings to control both land
                                                                                   A fire hose reel system must be provided to serve the development             least 2.9. Energy Efficiency Ratio (EER) means the tested average         the expected levels of preparation & application of painted
         and air born vermin.
                                                                                   in accordance with NCC Clause E1.4 and AS 2441. Fire hose reels               energy efficiency ratio for cooling as specified in ‘AS/NZS 3823.2        surfaces.
         FIRE RESISTANCE                                                           must be located within 4m of an exit. Any system valve which can              Performance of electrical appliances - airconditioners and heat
         External & internal fire separating walls must extend to the fire rated   isolate flow in the fire hose reel water supply main must be secured          pumps - energy labelling and minimum energy performance                   POWDERCOATING
         slab above or to the underside of the non-combustible roof                in the open position by a padlocked metal strap and labelled with             standard (MEPS) requirements’.                                            Preperation & application of Aluminium to be powdercoated shall
         covering and be sealed at that roof junction with compressed              an engraved non- ferrous tag with 8mm upper case wording ‘FIRE                All shower roses must have a minimum 3-star Water Efficiency              be to AAMA2604, AS4312 & AS3715
         mineral fibre wool. Any eaves must be protected to ensure that the        SERVICE VALVE- CLOSE ONLY TO SERVICE FIRE HOSE REELS’. Fire                   Labelling and Standards rating. Water Efficiency Labelling and            DOOR HANDLES
         fire separation between the units is maintained.                          hose reel cabinet signage must have 50mm high capital contrasting             Standards (WELS) - references the Australian Government’s                 Provide lever door handles located 900-1100mm above floor level
         Bedroom windows facing the common walkway must have a sill                letters ‘FIRE HOSE REEL’.                                                     labelling standards scheme for water efficient products.                  operable with a single hand.
         height not less than 1500mm above finished floor level and the wall       A sprinkler system must be provided to serve the basement in                  Toilet cisterns must have a dual flush function and have a minimum
         below the window must have a minimum 1hour fire resistance level          accordance with NCC Clause E1.5 and AS2118.1 except as                        4-star Water Efficiency Labelling and Standards rating and are            LIGHT SWITCHES
         to satisfy NCC Clause C3.11.                                              otherwise permitted by the approved Fire Engineering Report.                  compatible with the size of the toilet bowl to allow for proper           Provide light switches close to doorways and installed between
         The fire hazard properties of any material (including carpets, vinyls                                                                                   functioning of the toilet.                                                900- 1100mm above floor level.
                                                                                   FIRE SMOKE DETECTION AND ALARM SYSTEM
         & laminates) or assembly to comply with specification C1.10a of the                                                                                     Tap ware must have a minimum 3-star Water Efficiency Labelling            VEHICULAR ACCESS TO CARPARK
                                                                                   Provide fire smoke detection and alarm system in accordance with
         NCC (if a floor material, floor covering or a wall/ceiling lining) or                                                                                   and Standards rating for taps serving laundry tubs, kitchen sinks         Provide entry signage to carpark stating maximum clearance to
                                                                                   AS1670.1, and Electrical Engineer's drawings.
         comply with specification C1.10 if not a material applicable under                                                                                      and basins.                                                               carpark 2.2 metres. Provide flexible striker bars over entry down to
         specification C1.10a.                                                     FIRE EXTINGUISHERS                                                            Each meterable premises must have an electricity sub-meter                max. 2.2 metre height to comply with AS 2890.1 requirements.
         Spandrels must be provided to serve the building in                       Portable fire extinguishers must be provided in accordance with               installed which measures only the electricity supplied to that
         accordance with NCC Clause C2.6.                                          NCC Clause E1.6 and AS 2444. Provide a CO2 portable fire                      meterable premises in accordance with QDC MP4.1. The electricity          CARPARKING
         Electrical supplies to emergency equipment must be fire separated         extinguisher to serve each main switch board in the basement car              sub-meter must be installed in a common area, and be free of              Basement Carparking and External Carparking to comply with
         from the building in accordance with Clause C2.13 of the NCC. The         park. Provide a 3A40B(E) portable fire extinguisher adjacent to each          hindrance or obstruction to a person authorised to read and/or            AS 2890.1.
         main switchboard must be fire separated from the remainder of the         fire hose reel.                                                               maintain the electricity sub-meter. A meter label identifying which
                                                                                                                                                                                                                                           DRIVEWAY
         building by 120/120/120 fire resistant construction with the                                                                                            meterable premises it is associated with must be affixed or located
                                                                                   SMOKE ALARMS                                                                                                                                            Shall be in accordance with AS 2890.1 and Structural and Civil
         doorway protected by a self closing fire door having a fire                                                                                             adjacent to the electricity sub-meter for each meterable premises.
                                                                                   Provide hard wired smoke alarms in accordance with part E2 of the                                                                                       Engineer's drawings.
         resistance level not less than -/120/30. Any electrical conductors                                                                                      Glazing must be provided in accordance with AS1170, AS1288 &
                                                                                   NCC and AS 3786. Provide smoke detection systems in
         within the building that supply the main switchboard must be fire                                                                                       AS2047.                                                                   MAINTENANCE ACCESS
                                                                                   accordance with AS 1670 and Electrical Engineer's drawings.
         protected in accordance with Clause C2.13.                                                                                                                                                                                        Provide building maintenance access complying with Occupational
                                                                                                                                                                 BUILDING SEALING
         Every doorway that opens onto the External stairways must be              CARPARK AND UNIT MECHANICAL VENTILATION                                                                                                                 Health and Safety 2004 Codes of practice and AS 1891.4. Where a
                                                                                                                                                                 Window and doors; exhaust fans; construction of roofs, walls and
         protected by -/60/30 fire doors that are self closing in accordance       The car park exhaust system must comply with Clause 5.5 of                                                                                              person is exposed to the hazard of falling from a building or
                                                                                                                                                                 floors shall be in accordance with BCA part J3.4, J3.5 and J3.6.
         with NCC Clause C3.8a(ii) & (iii).                                        AS1668.1 with the controls for the QFES located to the satisfaction                                                                                     structure while cleaning or maintenance work is being carried out, a
         The lifts must be served by -/60/- fire doors complying with              of the QFES (typically at the car park vehicular entry point).                ROOF INSULATION                                                           system design to prevent such falls must be used. Where safety belt
         AS1735.11 that are set to remain in the closed position.                  Provide a mechanical ventilation system to all ensuites, bathrooms            R 2.5 bulk insulation ceiling batts to all Roofs. Refer XXXX report.      anchorage points are used they must be positioned on the building
         All penetrations through fire rated members must be fire protected        and laundries in accordance with Mechanical Engineer's                                                                                                  or structure so that a lifeline or safety harness may be attached
                                                                                                                                                                 WALL INSULATION
         in accordance with a tested prototype to maintain the fire resistance     documents and section F4 of the NCC and AS 1668.2 and AS/NZ                                                                                             before proceeding to a point where it is possible to fall.
                                                                                                                                                                 R 1.5 bulk insulation to Lightweight External Walls. Wall Insulation
         of the element being penetrated in accordance with NCC Clauses            3666.1                                                                                                                                                  Anchorage points for the attachment of safety harnesses must
                                                                                                                                                                 to Units not required. Refer XXXX report.
         C3.12 to C3.15.                                                                                                                                                                                                                   comply with AS 2626.
         An opening in a wall providing access to a garbage shaft must be
         protected by a door or hopper of non-combustible construction.




Notes:                                                                                                                                                         Rev       Date        Description                                                                                                                                                                                                                                            Project:                                                Drawing Title:       Project No.   Drawn By           Drawing No.
                                                                                                                                                               REV A     3/08/2023   PLANNING APPLICATION ISSUE
                                                                                                                                                                                                                                                                                                          Use figured dimensions in preference to scale.
                                                                                                                                                                                                                                                                                                          All dimensions to be varified and checked on                        B L A C K                Contact information:

                                                                                                                                                                                                                                                                                                          site. These designs, drawings, specifications
                                                                                                                                                                                                                                                                                                                                                                                                       PO Box 781 Tewantin Q 4565           Kauri Street Townhouses                                 GENERAL NOTES        202304        PT                 DA.03
                                                                                                                                                                                                                                                                                                                                                                                                       Architect Registration # 5386 QLD
                                                                                                                                                                                                                                                                                                          and the copyright thereof are the property of                                                                                     For Davrus
                                                                                                                                                                                                                                                                                                          Blackwood and must not be used, retained or                         W O O D                  Ph: 0416 037 424
                                                                                                                                                                                                                                                                                                                                                                                                       [email protected]      Lot 1 on RP203032 20 Kauri St, COOROY                   Scale                Date          Project Stage      Revision
                                                                                                                                                                                                                                                                                                          copied without the written authority of
                                                                                                                                                                                                                                                                                                          Blackwood.                                       a r c h i t e c t u r e   &   d e s i g n   www.blackwoodarchitecture.com.au     QLD 4563                                                1:100 @ A1           8/08/2023     Dev. Application   REV A
Log in to download the original file

202304 20 Kauri Street - DA REV.A 08.08.23.pdf · 11.4 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.