DRAWING SIZE — At
HEIGHT DATUM
LOT 2 ON RP 214048
Level Datum AHD
Lukes Road, Cooroy Mountain
= —_———
24
Survey information provided by
MAX WATTERSON & ASSOCIATES (MWA) |
9.96
+"
oa
0.03
+12!
+"
9.51
PROPOSED
ARENA
x
70.08
FFL
119.200
LEGEND
--~~ INDICATES PROPOSED SURFACE
48.077 CONTOURS AND LEVELS 10 AHD.
4480 EXISTING SURFACE SPOT LEVELS.
5.0% > INDICATES FINISHED SURFACE. GRADE
Fly INDICATES DIRECTION OF FALL
TO FINISHED SPOON DRAINS.
RAMP INDICATES DIRECTION OF RAMP UP OR
———— DOWN AS INDICATED
x [29.740] INDICATES PROPOSED FINISHED
SURFACE LEVELS
(T.J.) DENOTES WET TOOLED JOINT TO TERRACE
SLAB, REFER TO DRG. OW4.5 DETAILS
TERRACE SLAB. REFER TO STRUCTURAL
DETAILS FOR THICKNESS AND
REINFORCING.
DRIVEWAY SLAB/PAVEMENT. REFER TO
NOTES AND DETAILS ON DRG. OW4.5 FOR
THICKNESS AND REINFORCING.
LANDSCAPING, REFER LANDSCAPE
ARCHITECT FOR DETAILS.
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES WATER MAIN APPROX
—— w—————— ALIGNMENT, BUILDER TO CONFIRM EXACT
— sw/eEx
RW
LOCATION PRIOR TO WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAIN EXISTING
AS NOTED
INDICATES POSITION OF RETAINING WALL
TO STRUCTURAL ENGINEERS DETAIL.
www.dialbeforeyoudig.com.au
DIAL1100
BEFORE YOU DIG
EXISTING TABLE
DRAIN
4
+ 9.46
+"
PROPOSED |
STABLES _|
i FFL
vant ry
19,050)
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
CONTRACTOR TO TOPSOIL AND TURF ANY
DISTURBED OR DAMAGED AREAS OF THE ROAD
RESERVE ADJACENT THE CONSTRUCTION SITE
+
1JOIN PROPOSED DRIVEWAY INTO
- a EXISTING NEATLY, NO STEP
W713
6.84
+"
46.85
4
48.4
+!
3.21
+"
46.82
+!
7.03
+"
7!
09
IICAIERE
IO &
Ot KIROO
SR
Y
9:87
|
RESIDENTIAL
SITE PLAN — DRIVEWAY LEVELS PLAN PART 1
Scale 1: 250
ALL LINE MARKING TO BE IN ACCORDANCE
WITH THE QUEENSLAND MANUAL OF UNIFORM
TRAFFIC CONTROL DEVICES & A.S 2890.1
PARKING FACILITIES PART 1: OFF-STREET CAR
PARKING
CONTRACTOR TO REPAIR/REINSTATE ANY
DAMAGED AREAS OF EXISTING FOOTPATHS,
KERB & CHANNELS TO COUNCIL STANDARDS
CONTRACTOR TO REPAIR ADJACENT THE
CONSTRUCTION SITE KERB, FOOTPATH OR
ROAD RESERVE IF ANY DAMAGE IS SUSTAINED
DURING CONSTRUCTION. GRASSED AREAS ARE
TO BE RE TOP SOILED AND TURFED.
MAXIMUM CROSS-FALL OF 1 in 40 ON ALL
FOOT-PATHS AND INTERNAL PEDESTRIAN
PATHS AND RAMPS
Nl
or
LLLLLL,
41?
2.26
7
Oy
Lanny
\
‘. ‘ea
NEW KERB & CHANNEL TO BE IN ACCORDANCE
WITH IPWEA STANDARD Drg. SEQ-RS-080 &
COUNCIL STANDARD DETAILS
KE
EX. SWPT EXISTING STORMWATER PIT
EX. SWMH EXISTING STORMWATER MANHOLE
EX. SMH EXISTING SEWER MANHOLE
EX. SCP EXISTING SEWER CONNECTION POINT
E.0.B. EXISTING EDGE OF BITUMEN
K &C EXISTING KERB & CHANNEL
NS.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
4108 Tp TELSTRA PIT 1 91
EP, ELECTRICAL PILLAR
KERB EXISTING KERBING
RCEW REINFORCED CONCRETE END WALL
SV STOP VALVE
WM WATER METER
Pca +"
$49.08
10M
1:250 @ Al
1:500 @ A3
NOOSA COUNCIL
APPROVED PLAN
MCU26/0012 & OPW26/0034
27 APRIL 2026
Revision
Description
Date
Iss
* FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
SCG HOLDINGS PTY LTD T/
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
ABN 68 659 675 790
O SCG
aptgcompany
Title:
DRIVEWAY LEVELS PLAN
PART 1
Project
111 LUKES RD,
COOROY MOUNTAIN
Date: Feb 2026 Drawn LR Design 1H
. Checked: Drg No. Rev.
jeez 0577 -OW4.A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Approved Plan - MCU26 0012 & OPW26 0034 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.