Council archive · source document
SUPERSEDED - Approved Plan - MCU26 0012 & OPW26 0034 (As Published) · MCU26/0012
Plans and drawings: the text below has words only, no drawings.
Very large file (15.2 MB): may take a few minutes to open.
Original PDF page 7, section 1. The text section number identifies this passage in the reader.
¿ play your part - print on recycled paper 5m 4 3 2 1
Legend
bf1 Folded COLORBOND® steel barge
capping/flashing to be fixed in
accordance with manufacturers
specifications.
bf2 Folded COLORBOND® steel barge
capping/flashing to be fixed in
accordance with manufacturers
specifications.
eg1 Custom folded gutters in
COLORBOND® steel to be fixed in
accordance with manufacturers
specifications. Gutters to be in
accordance with hydraulic engineers
design and detail. Inner gutter to have
fall to rwo wth external gattuer flashing
flush to soffit.
pv Tiger Neo N-type JKM440N-54HL4R -
440 Watt PV panels to be installed on 1 2 3 4 5 6 7 8 9 10 11 12
316 s/s clamps. System to be installed 5,390 4,710 8,590 3,910 5,390 7,760 4,300 7,290 6,610 7,290 4,300
in accordance with specialist solar
electricians' design and detail. System
to be connected to battery storage/grid
connection.
rs1 Standing seam COLORBOND® steel
G
H
A
B
C
D
E
F
I
to be fixed in accordance with
manufacturers specifications. Provide
plywood substrate.
rs2 Suspended concrete roof to be in
accordance with structural engineers
design and detail. Provide fall to rwo in
accordance with hydraulic engineers
design and detail. Provide Emer-Proof
Advance waterproofing system
installed in accordance with
manufacturers specifications. Exposed
surfaces fascia & soffit to have acrylic A A
render system in accordance with
manufacturers specifications.
rwo 90mm rainwater gutter outlet installed
3,320
in accordance with gutter
manufacturers design and detail.
M eg1 rwo rwo eg1 rwo eg1 rwo
rwo
B B
27° pitch
eg1
4,730
rs1
eg1
M
bf1
27° pitch flue 27° pitch
eg1
C rwo
rs1 rs1 (under) 27
°p
rs2 itc
h
3,350
rwo
(under)
rwo eg1 rwo rwo eg1 rwo rs1
eg1
27° pitch
bf1
27° pitch
eg1
D
rwo
E
890
eg1 rwo rwo eg1 rwo eg1 rwo
rs1
rwo
pv
Skylight Skylight Skylight
N rwo rwo N
rwo
rwo rwo
bf1
27° pitch 27° pitch rs2
eg1
eg1
bf1
7,100
rs1 rs1 rs2 rwo
bf1 (under)
Skylight Skylight Skylight
rs2 rwo rwo
27° pitch
rs1 bf1
27° pitch
J
F F
27° pitch
bf1 rs1
bf2
bf2
2,700
rwo eg1 rwo rwo rwo
rs1 rs2
bf2
bf2
G G
3,100
bf2
bf2
pv
rs1
A
B
C
27° pitch
rs1
bf2
bf2
H bf1 H
1,400
27° pitch
rwo rwo
I (under) (under) I
rwo rwo
(under) (under)
G
H
D
E
F
I
5,390 4,710 8,590 3,910 5,390 7,760 4,300 7,290 6,610 7,290 4,300
1 2 3 4 5 6 7 8 9 10 11 12
NOOSA COUNCIL
APPROVED PLAN
Roof plan MCU26/0012 & OPW26/0034
1:100 27 APRIL 2026
/Users/benthornton/Documents/Cadfiles/2403 - Blake/Archicad/
01042026/2403.pln
sbt designs pty ltd t/a
Skale Building Design project Residence lot no. 2 DA02 Development application issue
Work in
Progress project number
Mobile: 0412 025 657
for Cameron & Jane Blake plan no. 214048 DA01 Development application issue 1/2/2026 2403
skale
building
Document Set design
ID: 24666197
skale.com.au
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at
111 Lukes Road
Cooroy Mountain
drawn
scale (A1) 1:100
BT CD15
Rev
Conceptual design
Details
11/12/2025
Date
DA02
drawing
08
-
number
WIP © Skale Building Design
Version: 1, Version Date: 08/04/2026
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Approved Plan - MCU26 0012 & OPW26 0034 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.