08/0203 - MCU - Multiple Housing Type 2 - Duplex [As Published] · 132008.203
Safety and security ‘) S71 The building entrance is clearly identifiable and | Lighting and paving will define and identify
O7 For Multiple Housing Types 2, 3 and 4, buildings and visible from the street, footpath and driveway; entrance.
outdoor spaces are designed to protect the personal security and | AND
safety of residents by allowing for natural surveillance $7.2 The interna! path network has clear sightlines to
the dwelling entry and street access points;
AND
57.3 Visitors have direct access to the entrance
without passing through private outdoor living areas.
Emergency access
08 For Multiple housing Type 3, 4 & 5, site design and layout | No solution provided Complies
ensures efficient access and egress for emergency vehicles. .
Separation of incompatible uses |
O9 Development is designed to minimise noise carrying 59.1 Bedroom windows are at least 3m away from Bedrooms are located away from the garages
between dwelling units or accommodation units by locating shared driveways or carparking areas of adjacent
noise sensitive spaces such as bedrooms away from noise dwelling units or accommodation units.
generating areas of the development, such as carparking areas or
mechanic plant and equipment or recreational facilities.
Mechanical plant & equipment
O10 Mechanical plant and equipment associated with
Residential Uses are designed and located so as not have an
adverse impact on the visual amenity of the site or surrounding
$10.1 Mechanical plant and equipment, including pool
and spa pumps, pool heaters, air-conditioning units Condition may be imposed in this regard
and refrigeration units are-
areas. a) where located at ground level, screened by fencing
1.5m in height or dense vegetation of at least 1.5m in
width incorporating grouped trees and shrubs with
maximum separation distance of 1m measured from
the centre of the plant; and
b) for Multiple housing Type 2, 3 & 4 are visually
integrated into the line and plane of the building and
roof design and do not project beyond the height or
width of the building when viewed from the street and
adjoining properties.
Ancillary recreation uses
Sii.1 Ifthe use involves ancillary use of outdoor [Not applicable
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0203 - MCU - Multiple Housing Type 2 - Duplex [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.