Approved Plans - RAL23 0021 & OPW23 0177

of 68

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings: the text below has words only, no drawings.

Very large file (101 MB): may take a few minutes to open.

Log in to see the plans as drawn
                                                              FIRE MANAGEMENT REPORT FM 5601-2



      PO4                         AO4.1
      Essential community         Development involving essential         The development does not
      infrastructure is able to   community infrastructure is not         involve essential community
      function effectively        located within a medium or high         infrastructure
      during and immediately      bushfire hazard area.
      after bushfire events.
                                  OR

                                  AO4.2
                                  Where located in a medium or
                                  high bushfire hazard area,
                                  development involving essential
                                  community infrastructure is
                                  designed to function effectively
                                  during and after a bushfire event
                                  in accordance with a Bushfire
                                  hazard Management Plan.
      PO5                         AO5.1
      Public safety and the       Hazardous materials are not             No hazardous material will be
      environment are not         manufactured or stored in bulk in       manufactured or stored in bulk
      adversely affected by the   a bushfire hazard area                  on site
      impacts of bushfire on
      hazardous materials
      manufacturing or storing
      on site
      PO6                         AO6.1
      Roads provide for easy      The road layout provides for            The access complies with “Fire
      and safe evacuation of      through -roads and avoids cul-de-       Hydrant and Vehicle Access
      premises and access by      sacs and dead-end roads                 Guidelines for Residential,
      emergency services.                                                 Commercial and Industrial Lots”
                                  OR                                      published by QFES and Qld
                                                                          Government.
                                  AO6.2
                                  The development has a perimeter
                                  road reserve with a minimum
                                  width of 20m and maximum
                                  gradient of 12.5%

                                  OR

                                  AO6.3
                                  Cul -de-sacs or no through roads
                                  are provided with fire trails or
                                  access easements, which are
                                  capable of being navigated by
                                  conventional vehicles and which
                                  link to through roads.

                                  AO6.4
                                  Safe access and egress is               The access complies with “Fire
                                  available at all times to all of the    Hydrant and Vehicle Access
                                  development for emergency               Guidelines for Residential,
                                  vehicles and personnel                  Commercial and Industrial Lots”
                                                                          published by QFES and Qld
                                                                          Government.

                                  AO6.5
                                  Where an emergency access               No emergency access point is
                                  point is required, it complies with     required
                                  the relevant works codes and
                                  PSP6 Engineering Design
                                  Standards




ELDON BOTTCHER ARCHITECT PTY LTD                     ©              18/10/23                            37
Log in to download the original file

Approved Plans - RAL23 0021 & OPW23 0177.pdf · 101 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.