Original source · versioned page text
Rfi - Attachment F - Hydraulic Services
28.10.13
MRP HYDRAULIC & FIRE SERVICES
TRANSMITTAL DOCUMENT
PROJECT NAME: PROJECT No. SHEET
TOWNHOUSE DEVELOPMENT 20-0877 1 of 1
DAY 27
ATTENTION: MONTH 01
YEAR 21
DESCRIPTION DWG No. REVISION
Site Plan - Water Services H-301 01
DOCUMENT TYPE Hard Copy
DWG Files
PLT Files
PDF Files ✓
DISTRIBUTION: NUMBER OF COPIES
Altum 01
METHOD OF TRANSMITTAL E
| C - Collect | D - Deliver | M - Mail | E - Email | U - Upload |
REASON FOR ISSUE SD
AS - As-Constructed | MCU - MCU Approval | OPA - Operational Works Approval
SD - Schematic Design | DD - Design Development | A - Approval | T - Tender | C - For Construction | P - Preliminary | I - Information |
MRP HYDRAULIC AND FIRE SERVICES CONSULTANTS PTY LTD
A: Suite 2/22 Denna St Po Box 646 P: (07) 5443 1000 E: [email protected]
Maroochydore Cotton Tree F: (07) 5443 1136 W: mrp.com.au
QLD 4558 QLD 4558
ABN: 23126 270 ACN: 126 270 326
BRISBANE CAIRNS ◼ SUNSHINE COAST TOWNSVILLE
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 1 page
Page 2
400mm
4100mm|
HYDRAULIC SERVICES
TOWNHOUSE DEVELOPMENT
101 & 105 EUMUNDI NOOSA ROAD
NOOSAVILLE QLD 4566
Lot 1 on RP230931 & Lot 1 on RP849431
Noosa Shire Council
Materials
1. WATER SUPPLY PIPE SIZES SPECIFIED ON THESE DRAWINGS ARE BASED ON
CALCULATIONS FOR PIPES HAVING EQUIVALENT DIMENSIONAL AND FLOW
CHARACTERISTICS TO THAT OF TYPE B COPPER TUBE. WHERE ALTERNATIVE
MATERIALS ARE USED AN EQUIVALENT PIPE SIZE APPROPRIATE TO THE MATERIAL
BEING USED SHALL BE SELECTED.
2. COLDWATER
FIRE (IN-GROUND)
FIRE (ABOVE-GROUND)
COPPER TYPE 'B'*
uPVC PRESSURE PIPE CLASS 'M' OR 'O'
GALVANISED STEEL
* PIPE AND FITTING MATERIALS MAY BE SUBSTITUTED PROVIDED ALTERNATIVE
MATERIALS ARE AUTHORIZED FOR USE IN ACCORDANCE WITH THE PLUMBING CODE OF |
AUSTRALIA (PCA). FOR WATER SERVICES REFER ALSO: AS/NZS3500.1 SECTION 2 AND
APPENDIX B - ACCEPTABLE PIPE AND FITTINGS | nr
SYMBOLS
|
” ISOLATION VALVE
|
ISOLATION VALVE IN PATH BOX |
a WATER METER |
DI DUAL-CV ob
R
SINGLE TESTABLE CHECK VALVE ) |
Sa ASSEMBLY INCLUDING ISOLATION ‘ ~
VALVES AND LINE STRAINER
c END CAP
C DROPPER
[e] IN-GROUND SPRING HYDRANT
eSMH
. ASSET ID; 2671212 {
LINETYPES - SERVICES BY OTHER'S SL 17.770 IL 16.020
3
2
APT 10
APT 11
BIO-RETENTION
IL 16.020 “~\ \ J
—— cs —— CIVIL-SEWERMAIN \o~ $s —_ 91508 ReTICy, -
iL 16.020 —— 7 SATION SEWER Many | S
NEW UTILITY WATER BRANCH | 5 SS) :
Ww
LINETYPES - PROPOSED ° IL 16. oof
—:—-+—-— COLDWATER Z 4
=
— — —__ FIRE SERVICE ge eSMH APT 06
Fm ASSET ID: 2663717 pf Ne ee ee ee ee ee ee ee Le .
LINETYPES - EXISTING 2 SL 18.330 FFL 19.000 oa a 8
EINE IFES = EAIS LING z . .
w COLD WATER me IL 16.040
3 | TH 04
c COMMUNICATIONS 2 ty]
@ | FFL 18.500
e ELECTRICAL 2 | |
8
s SEWER ° | |
sw STORMWATER : |
| |
ABBREVIATIONS 2
DUAL-CV Dual Check Valve |
DPH Dual Pillar Hydrant o
e : Existing
eFH Existing Fire Hydrant yp gy APT 01
MH Manhole r FFL 18.750
scv Single Check Valve o eSWMH
SEW Sewer m~.
SH Spring Hydrant ~s oO
SL Surface Level ™., —— IL 15.640 x
SMH Sewer Manhole ~~?) |
SWMH Stormwater Manhole IL 15.640 Ww
WM Water Meter eSMH s
wap Water Sub-Meter in Path Box ASSET ID: 2671213
SL 18.210
w IL 15.640
~, 7
~~
c
wy . = c
Building Information ~, ~—
BUILDING CLASSIFICATION 1a&2 ae
STOREYS CONTAINED 2 .— 1508 :
BUILDING FLOOR AREA <500m? - : se
SOIL CLASSIFICATION TBC
Ww Ww Ww Ww w—
NOTE: FIRE HYDRANTS LOCATED c ¢ ¢ c
IN ACCORDANCE WITH SPP ©3001, TRUNK WATER MAIN (ASSET ID: 6220114) \ W 7 v
EXISTING SERVICES DRAWN FROM HISTORICAL
RECORDS. CONTRACTOR TO CONFIRM THE
LOCATION, DIAMETER AND INVERT LEVELS OF ALL
EXISTING SERVICES ON-SITE PRIOR TO
COMMENCEMENT OF ANY WORKS AND ALLOW ALL
ASSOCIATED COSTS
NEW 150@ ‘PREMISES MAIN' ASSEMBLY
COMPLETE WITH 150 SINGLE TESTABLE
CHECK VALVE (50kPa SPRING) & 658 METERED
BY-PASS IN ACCORDANCE WITH BOUNDARY
CONNECTION DETAIL SEQ-WAT-1108-6.
SITE PLAN
a
50
ToOmm
Jason Van Dyke
3
8
2
8
5
3
8
3
g
g
s
—
NOTE: DRAWING REQUIRED TO WATER SERV! CES
BE PRINTED IN COLOUR
= ARCHITECT \ BUILDING DESIGNER CLIENT HYDRAULIC CONSULTANT PROJECT DESCRIPTION & ADDRESS HYDRAULIC SERVICE SHEET DESCRIPTION
40
27.01.21 | SD_ [ISSUED FOR DA HYDRANT RFI Tot [wo
Omm
DATE | stace DESCRIPTION [rev wo] AUTH.
BLACKBURNE JACKSON
DESIGN & ARCHITECTURE
37 AERODROME ROAD
MAROOCHYDORE QLD 4558
5443 3200
ALTUM CONSTRUCTIONS
MRP HYDRAULIC & FIRE SERVICES
CONSULTANTS PTY LTD
© BRISBANE m= SUNSHINE COAST
A: — Suite 2/22 Denna Street, Maroochydore, QLD.
PO Box 646, Cotton Tree, QLD, 4558.
P: (07) 5443 1000
E: [email protected]
P: — mrp.com.au
BSA: 1137134 ABN: 23 126 270 326 QBCC: 1137134
TOWNHOUSE DEVELOPMENT
401 & 105 EUMUNDI NOOSA ROAD
NOOSAVILLE QLD 4566
Lot 1 on RP230931 & Lot 1 on RP849431
SIMON LYNCH P" ‘eZ
DESIGNER DATE.
JASON VAN DYK | 27.01.21
SITE PLAN
WATER SERVICES
ISSUED FOR APPROVALS
PROJECT NUMBER, SCALE
20-0877
SHEET SIZE
Noted Al
‘SHEET NUMBER
H-201
REVISION
NUMBER 0 {
HAS)
E lo ls le lo lo
E IS IS is IS iB
100mm