Skip to the record
NoosaWatch™: The source of truth.

Original source · versioned page text

SUPERSEDED Reference Document - MCU22/0202

of 48

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                                                                                    Bushfire Hazard Assessment and Management Plan




                                             20,000 – 40,000 kW/m                                   High


                                              4,000–20,000 kW/m                                   Medium


                                                0 – 4,000 kW/m                          Low/Not bushfire prone


                Section 4.2.6 of the QFES BRC technical guide provides a series of mapping rules (‘patch and corridor
                filtering’) for modifying the potential fireline intensity of bushfire-prone areas to reflect the likelihood of
                lower potential fireline intensities in smaller vegetation patches and narrow vegetated corridors. These
                rules are applied as follows:

                       1. Remove patches of continuous fuel < 1 ha in area that are surrounded by either no fuel or non-
                             continuous fuel and are further than 100 m from any other continuous fuel greater than 2 ha;

                       2. Downgrade the effective fuel load of small patches of continuous fuel measuring a. 1 – 2 ha –
                             downgrade by 66% and b. 2 – 3 ha – downgrade by 50 % if the patch is surrounded by either
                             non-continuous fuel or a low-hazard vegetation or land-use type and if the patch is further than
                             100m from any other continuous -fuel vegetation patch greater than 2 ha; and

                       3. Remove narrow corridors and area of continuous fuel that are less than 50 m in width.

                Based on the results of the site-specific assessment, vegetation within the assessment area does not
                meet any of the patch and corridor filtering rules outlined in QFES (2019).

                The potential fireline intensity was calculated for bushfire-prone vegetation within 150 m of the site using
                the inputs from Steps 1 - 3. In accordance with Section 7.6 of the BRC Technical Guide, fireline intensity,
                radiant heat flux and bushfire attack level is not required to be calculated for non-bushfire prone (i.e.
                VHCs with a prone type of 2) or low hazard VHCs (i.e. VHCs with a prone-type of 3), therefore VHCs
                39.3 and 42.6 have been excluded from calculation of potential fireline intensity. Remodelled potential
                fireline intensity for bushfire-prone vegetation to the south and south-west of the site is provided in Table
                5:

                               Table 5: Potential fireline intensity for classified VHCs within 150 m assessment area


                     Location of                                  Effective slope –
                     classified                              average slope beneath         Fire       Potential   Potential   Remodelled
                  vegetation in                                    bushfire-prone        weather       fireline   bushfire     bushfire
                                       VHC         Status
                     relative to                             vegetation in relation      severity     intensity    hazard       hazard
                  development                                     to development          (FFDI)        (PFI)       class       class
                        area                                            (degrees)


                                                                                                       47,192
                         E             8.1        Remnant        5.5        Downslope       48                    Very High   Very High
                                                                                                     290 kW/m


                                                                                                       39,880
                        SE             8.1        Remnant        3.06       Downslope       48                      High        High
                                                                                                       kW/m


                                                                                                       37,067
                        NE             8.1        Remnant        2.0        Downslope       48                      High        High
                                                                                                       kW/m




                                                                         PR22428_BHAMP_199 Beddington Road, Doonan               Page 17
Document Set ID: 22623753
Version: 1, Version Date: 17/10/2023
Log in to download the original file

SUPERSEDED Reference Document - MCU22_0202.pdf · 4.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.