Skip to the record
Noosa's #1 Council Tracker.

Original source · versioned page text

SUPERSEDED Reference Document - MCU22/0202

of 48

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                                                                                                                                             Bushfire Hazard Assessment and Management Plan



                                                             Table 7: Assessment against the Noosa Plan 2020 – Bushfire Hazard Overlay Code.


                              Performance Outcomes                                       Acceptable Outcomes                                            Compliance Assessment

                Safety of people and property
                            Development maintains the safety of                Development which will materially increase the number of
                            people and property from the adverse               people living or congregating on premises, including           COMPLIES WITH PO1
                            impacts of bushfire.                       AO1.1   reconfiguring a lot, is not located within a medium or high
                                                                               bushfire hazard area.                                          The proposed new building will have an
                                                                                                                                              appropriate setback for a vulnerable use, not
                  PO1                                                          Development maximises setbacks from hazardous                  being exposed to greater than 10kW/m2 of
                                                                               vegetation to achieve an acceptable risk.                      radiant heat.
                                                                       AO1.2
                                                                               Editor’s Note — PSP8 Natural Hazards provides
                                                                               guidance for assessing bushfire hazard risk and
                                                                               preparing a bushfire hazard management plan.
                Impacts on Ecologically Important Areas
                            Bushfire mitigation measures do not                No acceptable outcome provided
                            adversely impact on:                                                                                              COMPLIES WITH PO2

                            a. biodiversity values, connectivity and                                                                          The development footprint will result in the
                            ecosystem functioning; and                                                                                        removal of a small number if native trees. The
                            b. the long term physical integrity of                                                                            proposed APZ does not require any additional
                  PO2       waterways, wetland and areas of native                                                                            native vegetation clearing. Therefore, the
                            vegetation.                                                                                                       proposal will have minimal impacts on
                                                                                                                                              biodiversity values, connectivity and ecosystem
                                                                                                                                              functioning. The proposal will also not impact on
                                                                                                                                              the long term physical of waterways, wetlands or
                                                                                                                                              areas of mapped native vegetation
                Water Supply for Fire Fighting Purposes
                            Development provides an adequate                   Premises are connected to the reticulated water supply.
                            water supply for fire fighting purpose                                                                            COMPLIES WITH AO3.2
                            which is reliable, safely located and              Editor's note—For reconfiguring a lot, water supply needs
                            freely accessible.                         AO3.1   to provide for a minimum flow and pressure of 10 litres a      The proposed dwelling will have the required
                  PO3                                                          second at 200kPa at all times for fire fighting purposes.      minimum level of stored, dedicated, on-site
                                                                                                                                              water supply for fire-fighting purposes. The site
                                                                               OR                                                             has access to a 48,000-litre drinking water
                                                                       AO3.2   Where there is no available reticulated water supply, the      supply and an additional two (2) 5,000 litre water




                                                                                                                                 PR22428_BHAMP_199 Beddington Road, Doonan                Page 27

Document Set ID: 22623753
Version: 1, Version Date: 17/10/2023
Log in to download the original file

SUPERSEDED Reference Document - MCU22_0202.pdf · 4.7 MB (large file)