2/16/23, 3:47 PM Flamesol - powered by FPA Australia & FPA | MES AUSTRALIA Calculated February 16, 2023, 4:46 pm (MDc v.4.9) 199 Beddington Rd East fire run SFR Inputs Fire Danger 48 Index Vegetation Forest classification Understorey fuel load Total fuel load Vegetation height Effective slope Site slope Flame width Windspeed Heat of combustion Flame temperature 31 t/ha 35 t/ha n/a 5.5° 7.27 ° 49.58 m n/a 18,600 kJ/kg 1,200 K Rate of spread Flame length Flame angle Elevation of receiver Fire intensity Transmissivity Viewfactor Minimum distance to < 40 kW/m2 Minimum distance to < 29 kW/m2 Minimum distance to < 19 kW/m2 Minimum distance to < 12.5 kW/m? Minimum distance to < 10 kW/m2 Outputs 2.6 km/h 21.16m 61.27 °, 66.27 °, 70.27 °, 74.27 °, 76.27 ° & 86,27 ° 6.51 m, 6.24 m, 5.46 m, 4.49 m, 3.86 m & Om 47,192 kW/m 0.848, 0.831, 0.8090000000000001, 0.79, 0.78 & 0.732 0.42, 0.3123, 0.2091, 0.1413, 0.1146 & 0.0305 21.7m 27m 35.2m 44.6m 50.3 m DocunstsifaaidBolaztaMDc_output.php?CALCTITLE=199+Beddington+Rd+EasttHire+trun+SFR&EFFECTIVESLOPE=5.5&SITESLOPE=7.278VE... 1/2 Version: 1, Version Date: 17/10/2023