Original source · versioned page text
Engineering Services Report
Attached to the e-mail MCU16/0066 & OPW16/0133 - Engineering report & Stormwater Mgmt Plan (2 of 4).
LEGEND IT'S HOW WE CONNECT For more info contact a Telstra Accredited Locater or Telstra Plan Services 1800 653 935 > << Exchange (major cable present) all: Footway access chamber (can vary from 1-lid to 12-lid) 2 «® Pillar/cabinet (above the ground / free standing) Above ground complex equipment housing (eg RIM) Please Note: This equipment is powered by 240V electricity. oc other carrier 4 P20 [ <—\——__ 2 pair lead-in to property from pit in street o59 <— 1 pair working (pair ID 059) 1DEAD 1 pair dead (i.e. spare, not connected) 107 Single to multiple round conduit < ° Ror B8e 888 Confgurations 1, 2, 4, 9 respectively P4100 (Attached text denotes conduit type and sze) Multiple square conduit Cer EH x EHEH Confgurations 2, 4, 6 respectively E85 (Attached text denotes conduit type and size) 6) Cable jointing pit (number indicating pit type) © Elevated cable joint (above ground joint on buried cable) ——}——. Telstra Plant in shared utility trench Aerial Cable (above ground) A A Aerial Cable (attached to joint use pole e.g. power) Direct buried cable ® @ —sSmoFr +— Optical fibre cable direct buried Marker post installed Buried transponder Marker, transponder Some examples of conduit type and size: A - Asbestos cement, P - PVC / plastic, C - Concrete, Gl - Galvanised iron, E - Earthenware. Condukt sizes nominally range from 20mm to 100mm. P50 50mm PVC conduit P100 100mm PVC conduit A100 100mm asbestos cement conduit E85 85mm square earthenware conduit Some examples of how to read Telstra plans: One 50mm PVC conduit (P50) containing a 50-pair and a 10-pair cable between two 6-pits, 20.0m apart, with a direct buried 30-pair cable Two separate conduit runs between two footway -50- —@Z— 3 30 1 S@— P50 20.0 along the same route. 2 8 S:Betsnses C100 BA - [cable nO mo} P100 access chambers (manholes) 245m apart. A nest of four 100mm PVC conduits (P100) containing assorted cables in three ducts (one af can 245.0 being empty) and one empty 100mm concrete duct (C100) along the same route. WARNING: Telstra plans and location information conform to Quality Level 'D' of the Australian Standard AS 5488 - Classification of Subsurface Utility Information. As such, Telstra supplied location information is indicative only. Spatial accuracy is not applicable to Quality Level D. Refer to AS 5488 for further details. Telstra does not warrant or hold out that its plans are accurate and accepts no responsibility for any inaccuracy shown on the plans. FURTHER ON SITE INVESTIGATION IS REQUIRED TO VALIDATE THE EXACT LOCATION OF TELSTRA PLANT PRIOR TO COMMENCING CONSTRUCTION WORK. A plant location service is an essential part of the process to validate the exact location of Telstra assets and to ensure the asset is protected during construction works. The exact position of Telstra assets can only be validated by physically exposing it. Telstra will seek compensation for damages caused to its property and losses caused to Telstra and its customers. TELSTRACORPORATION ACN 051 775 556
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.