13. APP H. Engineering Services Report
Attached to the e-mail MCU14/0102 Development Application 4 of 4 App H Engineering, App I Water quality, App J Economic Needs, App K Local Code response..
Original PDF page 13, section 1. The text section number identifies this passage in the reader.
6 ELECTRICAL, GAS AND
TELECOMMUNICATIONS SERVICES
A Dial Before You Dig search was undertaken to determine what services are currently in the
area and identify potential connection points for the proposed service station and retail centre
development.
6.1 Energex and other Electrical Items
Low voltage electrical cables currently exist within Lionel Donovan Drive, Eumundi Noosa Road
and Walter Hay Drive around the site.
It is understood that the proposed development must incorporate an underground low-voltage
electricity supply to all facilities within the development in order to comply with council
legislation. The existing overhead lines and poles bounding the site will remain overhead as the
development does not propose any additional allotments. Proposed verge crossings have also
been located clear of the existing overhead cable support poles. Refer to Appendix D for Dial
Before You Dig results by relevant asset holders.
6.2 Communications
There is existing Telstra infrastructure in the area to which the site is connected to. Telstra
infrastructure is located within the site, as well as within the Eumundi Noosa Road and Lionel
Donovan Drive road reserves adjacent to the site. The existing major cables pit to the north of
the existing northern verge crossover will remain in its current location, clear of all proposed
works.
There is also an existing underground Optus cable along Eumundi Noosa Road.
7 ROADS AND ACCESS
Currently, access to Lot 4 on SP159610 is accessible via a left in, left out facility at two locations
on Eumundi Noosa Road. Access to Lot 31 on SP170751 is provided via Lionel Donovan Drive,
however there is no constructed driveway to the lot in its current state.
The development proposes to maintain the left in, left out access on Eumundi Noosa Road,
however the access points will be shifted south to allow for heavy vehicle and fuel tanker entry
to the site. There will also be an access driveway on Lionel Donovan Drive to the site.
Pedestrians must be provided with safe and direct access around the service station and
industrial tennancies. Pedestrian access points will be provided from Eumundi Noosa Road and
Lionel Donovan Drive. Pedestrian crossings will also be included to provide safe passage for
pedestrians to the different outlets on site.
It is understood that all footpaths must be designed in accordance with Noosa Council
standards and be approved for Operational Works prior to construction.
Details of the proposed internal and external road network as well as the provided site access
points are presented in Hyder Engineering Drawings in Appendix C.
139 EUMUNDI-NOOSA ROAD & 30 LIONEL DONOVAN DRIVE, NOOSAVILLE
Hyder Consulting Pty Ltd-ABN 76 104 485 289 Page 8
f:\aa007595\f-reports\f0001-aar-aa007595 esr report\f0001-aa007595-aar-03 - esr.docx
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.