1 EXECUTIVE SUMMARY
Hyder Consulting has been engaged by Empirica Developments Pty Ltd to provide supporting
information for a Development Application over the following allotments;
• Lot 4 on SP159610 (139 Eumundi Noosa Road, Noosaville)
• Lot 31 on SP170751 (30 Lionel Donovan Drive, Noosaville)
This report addresses the engineering services component of the development and the
engineering planning issues associated with the development application. The proposed
development comprises the construction of an industrial development and service station.
This report demonstrates that the proposed development can be adequately serviced with
potable water, sewerage reticulation, stormwater drainage, vehicle access and electrical/
telecommunication services.
The proposed development has minimal impact on the surrounding network. As Lot 4 on
SP159610 is already used for industrial purposes, the proposed development will not result in
any increase of stormwater discharge on the site. There is a minor increase in peak discharge
on Lot 31 SP170751 in its developed state, which will be detained in a combined detention / bio-
retention at the legal point of discharge. Bio-retention systems will also be provided on site to
ensure that all stormwater quality objectives are met.
Hyder has received a Services Advice Notice from Unity Water in regards to sewer and potable
water connection. The site can be serviced for both sewer and potable water. It is proposed to
connect the site to the existing 100mm diameter water main on Eumundi Noosa Road and
Lionel Donovan Drive. The sewer will be connected to the existing 225mm diameter main that is
contained within Lot 31 SP170751.
Site access will be provided through left-in, left-out facilities on Eumundi Noosa Road. There will
also be an additional access from Lionel Donovan Drive. There will be an internal pedestrian
network to allow for the safe passage of pedestrians within the site, to and from external
networks in Noosa Eumundi Road and Lionel Donovan Drive.
Electrical and telecommunication services currently exist in the area. It is reasonable to expect
that the development will be able to connect directly to these services.
139 EUMUNDI-NOOSA ROAD & 30 LIONEL DONOVAN DRIVE, NOOSAVILLE
Hyder Consulting Pty Ltd-ABN 76 104 485 289 Page 1
f:\aa007595\f-reports\f0001-aar-aa007595 esr report\f0001-aa007595-aar-03 - esr.docx