                   c)    do not visually dominate the street or surrounding     the exposed external façade of the building cannot
                         spaces;                                                exceed 10 metres in building height..
                   d)    preserve the amenity of surrounding residential
                         development including privacy, views and access to
                         sunlight; and
                   e)    respond to the topography of the site and minimise
                         cut and fill where on a sloping site; and
                   f)    are well articulated with strong horizontal and
                         vertical elements to provide interest to the street.

               The proposed building exceeds 10 metres in building height, being 12.12 metres at the roof pitch.
               The applicant submits that the proposal meets PO8 as:
               •        The subject site is located in a medium impact industry area and adjoins lots that are within the
                        Venture Drive Precinct, which promotes medium scale industrial land uses. Uses of this nature
                        typically require large, bulkier built form to accommodate industrial activities.
               •        Previously the design incorporated parapet walls that extended up beyond roof edges. This
                        concealed the roof form. The design has been revised to introduce eaves, and a pitched roof
                        is now visible. The effect of this twofold: -
                           - The revised design is now consistent in form with the surrounding development, including
                              with the form of the development which immediately adjoins at 11 to 13 Vision Court.
                           - This has also reduced the height of the building at the northern and southern elevations
                              and reduces the apparent mass and bulk of the building when viewed from the street.
               •        The proposed development is in context of the development at 11 to 13 Vision Court. This
                        adjoining development is now complete and operational. With the introduction of eaves and a
                        pitched roof to the proposal, building height is consistent with that of the existing adjoining
                        development. A streetscape elevation is provided below.




               •




                                                       Figure 6 – Applicant’s streetscape elevation




Document Set ID: 22553288
Version: 12, Version Date: 09/10/2023

Used in these records

About this file

File size
5.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

PLANNING & ENVIRONMENT REPORT - MCU22 0051 - Final Report [As Published].pdf · 5.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.